Technique for improving concrete characteristics with bacillus: Insights on strength and durability

IF 1.6 Q2 MULTIDISCIPLINARY SCIENCES
MethodsX Pub Date : 2024-12-31 DOI:10.1016/j.mex.2024.103151
Sayali Sandbhor, Sayali Apte, Shubham Puranik, Mansi Asati, Samyak Rai
{"title":"Technique for improving concrete characteristics with bacillus: Insights on strength and durability","authors":"Sayali Sandbhor,&nbsp;Sayali Apte,&nbsp;Shubham Puranik,&nbsp;Mansi Asati,&nbsp;Samyak Rai","doi":"10.1016/j.mex.2024.103151","DOIUrl":null,"url":null,"abstract":"<div><div>Numerous problems, including weathering, cracks, leaks, and bending, among others, appear in concrete after construction. The optimum procedure for treating concrete cracks is the subject of this study. The research goal is to find potential crack treatment materials and analyze the effect on the properties of concrete caused by the addition of bacterial solution to the concrete mix along with a particular method of preparation of bacterial solution. The principal results of the experimental testing showcased a successive growth in the compressive strength when the concrete cubes were casted with the bacterial addition from Bacillus family with a significant change in the quality of concrete. Following are the primary research outcomes of the method:<ul><li><span>•</span><span><div>Use of Bacillus bacterial with direct addition in concrete improves concrete's performance.</div></span></li><li><span>•</span><span><div>The proposed method of concrete mix with Bacillus Sphaericus Solution in 30 ml concentration, replacing partial water cement ratio, yields maximum compressive strength on 28th day curing. For expediting setting time with high compressive strength, adding Bacillus Sphaericus solution in 45 ml concentration is recommended.</div></span></li><li><span>•</span><span><div>For achieving a homogenous mix with lesser cracks on 28th day, Bacillus Subtilis Spores in 30 ml concentration can be added to concrete with partial replacement of the water requirement.</div></span></li></ul></div></div>","PeriodicalId":18446,"journal":{"name":"MethodsX","volume":"14 ","pages":"Article 103151"},"PeriodicalIF":1.6000,"publicationDate":"2024-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11758841/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"MethodsX","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2215016124006022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Numerous problems, including weathering, cracks, leaks, and bending, among others, appear in concrete after construction. The optimum procedure for treating concrete cracks is the subject of this study. The research goal is to find potential crack treatment materials and analyze the effect on the properties of concrete caused by the addition of bacterial solution to the concrete mix along with a particular method of preparation of bacterial solution. The principal results of the experimental testing showcased a successive growth in the compressive strength when the concrete cubes were casted with the bacterial addition from Bacillus family with a significant change in the quality of concrete. Following are the primary research outcomes of the method:
  • Use of Bacillus bacterial with direct addition in concrete improves concrete's performance.
  • The proposed method of concrete mix with Bacillus Sphaericus Solution in 30 ml concentration, replacing partial water cement ratio, yields maximum compressive strength on 28th day curing. For expediting setting time with high compressive strength, adding Bacillus Sphaericus solution in 45 ml concentration is recommended.
  • For achieving a homogenous mix with lesser cracks on 28th day, Bacillus Subtilis Spores in 30 ml concentration can be added to concrete with partial replacement of the water requirement.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
MethodsX
MethodsX Health Professions-Medical Laboratory Technology
CiteScore
3.60
自引率
5.30%
发文量
314
审稿时长
7 weeks
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信