{"title":"Magnetic field probe-based co-simulation method for irregular volume-type inductively coupled wireless MRI radiofrequency coils","authors":"Ming Lu ,&nbsp;Hao Liang ,&nbsp;Haoqin Zhu ,&nbsp;Xinqiang Yan","doi":"10.1016/j.mri.2025.110330","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Inductively coupled wireless coils are increasingly used in MRI due to their cost-effectiveness and simplicity, eliminating the need for expensive components like preamplifiers, baluns, coil plugs, and coil ID circuits. Existing tools for predicting component values and electromagnetic (EM) fields are primarily designed for cylindrical volume coils, making them inadequate for irregular volume-type wireless coils.</div></div><div><h3>Purpose</h3><div>The aim of this study is to introduce and validate a novel magnetic (H-) field probe-based co-simulation method to accurately predict capacitance values and EM fields for irregular volume-type wireless coils, thereby addressing the limitations of current prediction tools.</div></div><div><h3>Methods</h3><div>The proposed method involves several key steps: modeling the coil in EM simulation software, replacing lumped components with 50-Ω ports, placing well-decoupled double pick-up sniffer probes within the wireless coil, conducting full-wave EM simulations, and exporting the S-parameter matrix to an RF circuit simulation tool for optimization. The RF circuit simulation optimizes component values by maximizing the average magnitude of the root square of Sxys (mean_√Sxy) of double probes and minimizing the normalized standard deviation of √Sxy (normStd_√Sxy). The optimized capacitance values are validated through re-performing EM simulations, and hardware prototypes are fabricated and tested in MRI experiments.</div></div><div><h3>Results</h3><div>The method was validated using bottle-shaped and dome-shaped Litzcage coils designed for 1.5 T MRI. Consistent resonant peaks and magnetic field distributions were observed across different coil designs. The optimized capacitance values obtained from circuit-level simulations were confirmed through EM simulations. Significant SNR enhancements were observed in MRI experiments, with the wireless hand and wrist/head coil showing an overall SNR enhancement of 12.8/3.4-fold in EM simulation and 13.4/3.8-fold in MRI experiments, compared to the body coil alone.</div></div><div><h3>Conclusions</h3><div>The H-field probe-based co-simulation method provides an efficient and accurate solution for designing and optimizing irregular wireless RF coils in MRI. By integrating EM simulation, H-field probes, and RF circuit optimization, this method reduces the need for extensive full-wave EM simulations and accurately predicts capacitance values and EM fields. The validation using irregular Litzcage coils demonstrated the method's efficacy, contributing to improved imaging quality in MRI applications. This approach offers a valuable tool for coil developers and researchers, facilitating the development of high-quality irregular wireless coils for enhanced MRI performance.</div></div>","PeriodicalId":18165,"journal":{"name":"Magnetic resonance imaging","volume":"117 ","pages":"Article 110330"},"PeriodicalIF":2.1000,"publicationDate":"2025-01-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance imaging","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0730725X25000128","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Inductively coupled wireless coils are increasingly used in MRI due to their cost-effectiveness and simplicity, eliminating the need for expensive components like preamplifiers, baluns, coil plugs, and coil ID circuits. Existing tools for predicting component values and electromagnetic (EM) fields are primarily designed for cylindrical volume coils, making them inadequate for irregular volume-type wireless coils.

Purpose

The aim of this study is to introduce and validate a novel magnetic (H-) field probe-based co-simulation method to accurately predict capacitance values and EM fields for irregular volume-type wireless coils, thereby addressing the limitations of current prediction tools.

Methods

The proposed method involves several key steps: modeling the coil in EM simulation software, replacing lumped components with 50-Ω ports, placing well-decoupled double pick-up sniffer probes within the wireless coil, conducting full-wave EM simulations, and exporting the S-parameter matrix to an RF circuit simulation tool for optimization. The RF circuit simulation optimizes component values by maximizing the average magnitude of the root square of Sxys (mean_√Sxy) of double probes and minimizing the normalized standard deviation of √Sxy (normStd_√Sxy). The optimized capacitance values are validated through re-performing EM simulations, and hardware prototypes are fabricated and tested in MRI experiments.

Results

The method was validated using bottle-shaped and dome-shaped Litzcage coils designed for 1.5 T MRI. Consistent resonant peaks and magnetic field distributions were observed across different coil designs. The optimized capacitance values obtained from circuit-level simulations were confirmed through EM simulations. Significant SNR enhancements were observed in MRI experiments, with the wireless hand and wrist/head coil showing an overall SNR enhancement of 12.8/3.4-fold in EM simulation and 13.4/3.8-fold in MRI experiments, compared to the body coil alone.

Conclusions

The H-field probe-based co-simulation method provides an efficient and accurate solution for designing and optimizing irregular wireless RF coils in MRI. By integrating EM simulation, H-field probes, and RF circuit optimization, this method reduces the need for extensive full-wave EM simulations and accurately predicts capacitance values and EM fields. The validation using irregular Litzcage coils demonstrated the method's efficacy, contributing to improved imaging quality in MRI applications. This approach offers a valuable tool for coil developers and researchers, facilitating the development of high-quality irregular wireless coils for enhanced MRI performance.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Magnetic resonance imaging
Magnetic resonance imaging 医学-核医学
CiteScore
4.70
自引率
4.00%
发文量
194
审稿时长
83 days
期刊介绍: Magnetic Resonance Imaging (MRI) is the first international multidisciplinary journal encompassing physical, life, and clinical science investigations as they relate to the development and use of magnetic resonance imaging. MRI is dedicated to both basic research, technological innovation and applications, providing a single forum for communication among radiologists, physicists, chemists, biochemists, biologists, engineers, internists, pathologists, physiologists, computer scientists, and mathematicians.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信