Characteristics of In Vivo Lesion Formation With a Temperature-Controlled Diamond-Tip Radiofrequency Ablation Catheter in the Ventricle: A Preclinical Model.

IF 9.1 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
Tatsuhiko Hirao, Maryam E Rettmann, Megan Schmidt, Omar Yasin, Gurukripa N Kowlgi, Naoto Otsuka, Taro Koya, Laura Newman, Douglas L Packer, Konstantinos C Siontis
{"title":"Characteristics of In Vivo Lesion Formation With a Temperature-Controlled Diamond-Tip Radiofrequency Ablation Catheter in the Ventricle: A Preclinical Model.","authors":"Tatsuhiko Hirao, Maryam E Rettmann, Megan Schmidt, Omar Yasin, Gurukripa N Kowlgi, Naoto Otsuka, Taro Koya, Laura Newman, Douglas L Packer, Konstantinos C Siontis","doi":"10.1161/CIRCEP.124.013120","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Power-controlled radiofrequency ablation with irrigated-tip catheters has been the norm for ventricular ablation for almost 2 decades. New catheter technology has recently integrated more accurate tissue temperature sensing enabling temperature-controlled irrigated ablation. We aimed to investigate the in vivo ablation parameters and lesion formation characteristics in ventricular myocardium using a novel temperature-controlled radiofrequency catheter.</p><p><strong>Methods: </strong>Twenty canines were divided into 3 groups: 4 noninfarcted, acute (phase I); 8 noninfarcted, chronic (phase II); and 8 infarcted, chronic (phase III). Lesions were delivered with a temperature-controlled radiofrequency system utilizing a chemical vapor deposit diamond for efficient thermal diffusivity. In phase I, 17 ablation settings were tested (temperature set points, 50/60/70 °C; ablation duration, 15/30/60/90/120 s; and power limit, 30/50 W). Four and one of these sets of parameters were further tested in phases II and III, respectively. Lesions were assessed by ex vivo contrast-enhanced magnetic resonance imaging and gross pathology 5 weeks after ablation in phases II/III.</p><p><strong>Results: </strong>Across all phases, 111 ablation lesions were delivered. Ablation with the power limit of 50 W, the temperature set point of 60 °C, and the duration of 60 s produced significantly larger and deeper lesions (mean, 569.2 mm<sup>3</sup>; mean maximal depth, 9.8 mm) compared with 50 W/60 °C/30 s (mean, 340.4 mm<sup>3</sup>; mean maximal depth, 8.3 mm) and 50 W/50 °C/60 s (mean, 227 mm<sup>3</sup>; mean maximal depth, 6.9 mm), with <i>P</i><0.05 for all pairwise comparisons. Ablation of infarcted myocardium in phase III (50 W/60 °C/30 s) resulted in smaller impedance and bipolar electrogram amplitude changes and lesion size compared with ablation in normal myocardium with the same settings. No steam pop, myocardial perforation, or char formation was observed in any of the 111 ablations across all phases.</p><p><strong>Conclusions: </strong>In vivo radiofrequency ablation in a canine model with a diamond-tip temperature-controlled catheter using a temperature set point of 60 °C and a power limit of 50 W created large lesions without steam pop risk in both normal and infarcted ventricular myocardia.</p>","PeriodicalId":10319,"journal":{"name":"Circulation. Arrhythmia and electrophysiology","volume":" ","pages":"e013120"},"PeriodicalIF":9.1000,"publicationDate":"2025-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation. Arrhythmia and electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1161/CIRCEP.124.013120","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Power-controlled radiofrequency ablation with irrigated-tip catheters has been the norm for ventricular ablation for almost 2 decades. New catheter technology has recently integrated more accurate tissue temperature sensing enabling temperature-controlled irrigated ablation. We aimed to investigate the in vivo ablation parameters and lesion formation characteristics in ventricular myocardium using a novel temperature-controlled radiofrequency catheter.

Methods: Twenty canines were divided into 3 groups: 4 noninfarcted, acute (phase I); 8 noninfarcted, chronic (phase II); and 8 infarcted, chronic (phase III). Lesions were delivered with a temperature-controlled radiofrequency system utilizing a chemical vapor deposit diamond for efficient thermal diffusivity. In phase I, 17 ablation settings were tested (temperature set points, 50/60/70 °C; ablation duration, 15/30/60/90/120 s; and power limit, 30/50 W). Four and one of these sets of parameters were further tested in phases II and III, respectively. Lesions were assessed by ex vivo contrast-enhanced magnetic resonance imaging and gross pathology 5 weeks after ablation in phases II/III.

Results: Across all phases, 111 ablation lesions were delivered. Ablation with the power limit of 50 W, the temperature set point of 60 °C, and the duration of 60 s produced significantly larger and deeper lesions (mean, 569.2 mm3; mean maximal depth, 9.8 mm) compared with 50 W/60 °C/30 s (mean, 340.4 mm3; mean maximal depth, 8.3 mm) and 50 W/50 °C/60 s (mean, 227 mm3; mean maximal depth, 6.9 mm), with P<0.05 for all pairwise comparisons. Ablation of infarcted myocardium in phase III (50 W/60 °C/30 s) resulted in smaller impedance and bipolar electrogram amplitude changes and lesion size compared with ablation in normal myocardium with the same settings. No steam pop, myocardial perforation, or char formation was observed in any of the 111 ablations across all phases.

Conclusions: In vivo radiofrequency ablation in a canine model with a diamond-tip temperature-controlled catheter using a temperature set point of 60 °C and a power limit of 50 W created large lesions without steam pop risk in both normal and infarcted ventricular myocardia.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
13.70
自引率
4.80%
发文量
187
审稿时长
4-8 weeks
期刊介绍: Circulation: Arrhythmia and Electrophysiology is a journal dedicated to the study and application of clinical cardiac electrophysiology. It covers a wide range of topics including the diagnosis and treatment of cardiac arrhythmias, as well as research in this field. The journal accepts various types of studies, including observational research, clinical trials, epidemiological studies, and advancements in translational research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信