Therapy Potential of Oblique Lumbar Interbody Fusion 360 for Severe Lumbar Spinal Stenosis.

IF 1.8 2区 医学 Q2 ORTHOPEDICS
Lei Li, Yan Wang, Hao Zhang, Jialuo Han, Changpeng Qu, Yihao Sun, Hao Tao, Xuexiao Ma
{"title":"Therapy Potential of Oblique Lumbar Interbody Fusion 360 for Severe Lumbar Spinal Stenosis.","authors":"Lei Li, Yan Wang, Hao Zhang, Jialuo Han, Changpeng Qu, Yihao Sun, Hao Tao, Xuexiao Ma","doi":"10.1111/os.14363","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The advent of O-arm navigation optimized the oblique lumbar interbody fusion (OLIF) procedure, allowing the operator to simultaneously perform OLIF and percutaneous posterior pedicle screw implantation without patient position change, thus improving the fluency and accuracy of the OLIF procedure (called as OLIF360). Nevertheless, a consensus regarding its suitability for patients with severe spinal stenosis remains elusive. This study aims to investigate the clinical efficacy of OLIF360 and its imaging changes in severe lumbar spinal stenosis cases.</p><p><strong>Methods: </strong>This retrospective study analyzed clinical data from 63 patients with severe lumbar spinal stenosis. Fourteen patients were treated with OLIF360, and another 37 patients were treated with posterior lumbar interbody fusion (PLIF). Lumbar spinal stenosis was assessed using the modified Schizas classification. Clinical efficacy scale scores and postoperative imaging parameter changes were compared between the two groups. Shapiro-Wilk, t-tests or Mann-Whitney U tests, repeated measures ANOVA, and Bonferroni post hoc tests were applied for statistical analysis.</p><p><strong>Results: </strong>Both groups showed significant improved pain (p < 0.05). At 1-month and 3-month postoperative follow-ups, OLIF360 group scores superior in Visual Analog Scale than PLIF group (p < 0.05). Greater disc height and lumbar lordosis were displayed in OLIF360 group than PLIF group (p < 0.05). No significant difference in screw placement accuracy between groups was observed. Moreover, significant increases in spinal canal area postoperatively (71.04 ± 6.27 mm<sup>2</sup> preop to 109.65 ± 12.34 mm<sup>2</sup> postop, p < 0.05) and bilateral foraminal areas were found in the OLIF360 group.</p><p><strong>Conclusion: </strong>OLIF360 can have promising short-term efficacy for severe lumbar stenosis treatment with shorter recovery time than PLIF.</p>","PeriodicalId":19566,"journal":{"name":"Orthopaedic Surgery","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthopaedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/os.14363","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: The advent of O-arm navigation optimized the oblique lumbar interbody fusion (OLIF) procedure, allowing the operator to simultaneously perform OLIF and percutaneous posterior pedicle screw implantation without patient position change, thus improving the fluency and accuracy of the OLIF procedure (called as OLIF360). Nevertheless, a consensus regarding its suitability for patients with severe spinal stenosis remains elusive. This study aims to investigate the clinical efficacy of OLIF360 and its imaging changes in severe lumbar spinal stenosis cases.

Methods: This retrospective study analyzed clinical data from 63 patients with severe lumbar spinal stenosis. Fourteen patients were treated with OLIF360, and another 37 patients were treated with posterior lumbar interbody fusion (PLIF). Lumbar spinal stenosis was assessed using the modified Schizas classification. Clinical efficacy scale scores and postoperative imaging parameter changes were compared between the two groups. Shapiro-Wilk, t-tests or Mann-Whitney U tests, repeated measures ANOVA, and Bonferroni post hoc tests were applied for statistical analysis.

Results: Both groups showed significant improved pain (p < 0.05). At 1-month and 3-month postoperative follow-ups, OLIF360 group scores superior in Visual Analog Scale than PLIF group (p < 0.05). Greater disc height and lumbar lordosis were displayed in OLIF360 group than PLIF group (p < 0.05). No significant difference in screw placement accuracy between groups was observed. Moreover, significant increases in spinal canal area postoperatively (71.04 ± 6.27 mm2 preop to 109.65 ± 12.34 mm2 postop, p < 0.05) and bilateral foraminal areas were found in the OLIF360 group.

Conclusion: OLIF360 can have promising short-term efficacy for severe lumbar stenosis treatment with shorter recovery time than PLIF.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Orthopaedic Surgery
Orthopaedic Surgery ORTHOPEDICS-
CiteScore
3.40
自引率
14.30%
发文量
374
审稿时长
20 weeks
期刊介绍: Orthopaedic Surgery (OS) is the official journal of the Chinese Orthopaedic Association, focusing on all aspects of orthopaedic technique and surgery. The journal publishes peer-reviewed articles in the following categories: Original Articles, Clinical Articles, Review Articles, Guidelines, Editorials, Commentaries, Surgical Techniques, Case Reports and Meeting Reports.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信