Quantification and clinical performance of serum parathyroid hormone 1–84 via immunocapture coupled to LC–MS/MS in chronic renal failure

IF 3.1 3区 医学 Q2 CHEMISTRY, ANALYTICAL
Haiwei Cao , Yuting Jin , Yingwu Wang , Hao Wang , Yijia Qin , Xinhua Guo , Suyan Tian , Jing Huang , Yanyan Li
{"title":"Quantification and clinical performance of serum parathyroid hormone 1–84 via immunocapture coupled to LC–MS/MS in chronic renal failure","authors":"Haiwei Cao ,&nbsp;Yuting Jin ,&nbsp;Yingwu Wang ,&nbsp;Hao Wang ,&nbsp;Yijia Qin ,&nbsp;Xinhua Guo ,&nbsp;Suyan Tian ,&nbsp;Jing Huang ,&nbsp;Yanyan Li","doi":"10.1016/j.jpba.2025.116678","DOIUrl":null,"url":null,"abstract":"<div><div>Accurate measurement of serum parathyroid hormone (PTH) is crucial for diagnosing and managing endocrine and osteological diseases. Conventional immunoassay methods struggle with cross reactivity issues between full-length PTH and truncated fragments or post-translationally modified forms. Both the standardization of PTH assays and the peptide's stability are concerning. This study addresses these issues by establishing an immunocapture coupled with liquid chromatography–tandem mass spectrometry (LC–MS/MS) method to precisely quantify PTH1–84. PTH1–84 was isolated from one mL serum samples by immunocapture on a polystyrene bead and eluted from matrix, then quantitated by LC–MS/MS. The results from 268 serum samples were compared to an intact PTH immunoassay. The assay's linear range was 5.0–1000.0 pg/mL. The intra-assay coefficients of variation (CVs) ranged from 3.2 % to 6.8 %, and the inter-assay CVs ranged from 4.6 % to 9.5 %. The extraction efficiencies were 98.0 %–100.5 %, with no significant matrix effects observed after internal standard correction. The correlation coefficient between LC–MS/MS and immunoassay was 0.989, but the bias between the methods was substantial. Nevertheless, the immunocapture purification coupled LC–MS/MS method offers a promising approach for accurate PTH measurement.</div></div>","PeriodicalId":16685,"journal":{"name":"Journal of pharmaceutical and biomedical analysis","volume":"256 ","pages":"Article 116678"},"PeriodicalIF":3.1000,"publicationDate":"2025-01-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pharmaceutical and biomedical analysis","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0731708525000196","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Accurate measurement of serum parathyroid hormone (PTH) is crucial for diagnosing and managing endocrine and osteological diseases. Conventional immunoassay methods struggle with cross reactivity issues between full-length PTH and truncated fragments or post-translationally modified forms. Both the standardization of PTH assays and the peptide's stability are concerning. This study addresses these issues by establishing an immunocapture coupled with liquid chromatography–tandem mass spectrometry (LC–MS/MS) method to precisely quantify PTH1–84. PTH1–84 was isolated from one mL serum samples by immunocapture on a polystyrene bead and eluted from matrix, then quantitated by LC–MS/MS. The results from 268 serum samples were compared to an intact PTH immunoassay. The assay's linear range was 5.0–1000.0 pg/mL. The intra-assay coefficients of variation (CVs) ranged from 3.2 % to 6.8 %, and the inter-assay CVs ranged from 4.6 % to 9.5 %. The extraction efficiencies were 98.0 %–100.5 %, with no significant matrix effects observed after internal standard correction. The correlation coefficient between LC–MS/MS and immunoassay was 0.989, but the bias between the methods was substantial. Nevertheless, the immunocapture purification coupled LC–MS/MS method offers a promising approach for accurate PTH measurement.
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.70
自引率
5.90%
发文量
588
审稿时长
37 days
期刊介绍: This journal is an international medium directed towards the needs of academic, clinical, government and industrial analysis by publishing original research reports and critical reviews on pharmaceutical and biomedical analysis. It covers the interdisciplinary aspects of analysis in the pharmaceutical, biomedical and clinical sciences, including developments in analytical methodology, instrumentation, computation and interpretation. Submissions on novel applications focusing on drug purity and stability studies, pharmacokinetics, therapeutic monitoring, metabolic profiling; drug-related aspects of analytical biochemistry and forensic toxicology; quality assurance in the pharmaceutical industry are also welcome. Studies from areas of well established and poorly selective methods, such as UV-VIS spectrophotometry (including derivative and multi-wavelength measurements), basic electroanalytical (potentiometric, polarographic and voltammetric) methods, fluorimetry, flow-injection analysis, etc. are accepted for publication in exceptional cases only, if a unique and substantial advantage over presently known systems is demonstrated. The same applies to the assay of simple drug formulations by any kind of methods and the determination of drugs in biological samples based merely on spiked samples. Drug purity/stability studies should contain information on the structure elucidation of the impurities/degradants.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信