Relationship of maternal ophthalmic artery Doppler with uterine artery Doppler, hemodynamic indices and gestational age: prospective MATERA study.

IF 6.1 1区 医学 Q1 ACOUSTICS
Ultrasound in Obstetrics & Gynecology Pub Date : 2025-02-01 Epub Date: 2025-01-20 DOI:10.1002/uog.29162
S Ali, D C Mukasa, D Lukakamwa, A Nakayenga, P Namagero, J Biira, J Byamugisha, A T Papageorghiou
{"title":"Relationship of maternal ophthalmic artery Doppler with uterine artery Doppler, hemodynamic indices and gestational age: prospective MATERA study.","authors":"S Ali, D C Mukasa, D Lukakamwa, A Nakayenga, P Namagero, J Biira, J Byamugisha, A T Papageorghiou","doi":"10.1002/uog.29162","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To examine the relationship of ophthalmic artery (OA) Doppler indices with uterine artery (UtA) Doppler indices, selected maternal hemodynamic parameters and gestational age, and to evaluate the intraobserver reproducibility of OA Doppler indices.</p><p><strong>Methods: </strong>This was a prospective cohort study of women recruited between 11 + 0 and 23 + 6 weeks' gestation using a stratified and random sampling approach to ensure adequate distribution across the gestational-age range. OA pulsatility index (PI), first peak systolic velocity (PSV1), second peak systolic velocity (PSV2) and peak systolic velocity ratio (PSV ratio), calculated as PSV2/PSV1, were measured twice in each eye by the same observer. UtA-PI was also measured twice on each side by the same observer. Maternal hemodynamic assessment was undertaken using an ultrasonic cardiac output monitor (USCOM 1A). Pearson's and Spearman's rank correlation coefficients were used to assess the correlations between variables, and Bland-Altman plots were used to evaluate the intraobserver reproducibility of OA Doppler indices.</p><p><strong>Results: </strong>Of 194 women invited to participate in the study, 169 were eligible for inclusion, of whom 16 were excluded following an obstetric ultrasound scan and a further three owing to inadequate or incomplete OA or UtA Doppler assessment, leaving 150 women in the final analysis. Log UtA-PI had a weak correlation with both OA-PI (r = -0.19 (95% CI, -0.34 to -0.03), P = 0.021) and OA-PSV ratio (r = 0.31 (95% CI, 0.15-0.45), P < 0.001). The correlation between gestational age and OA-PI was non-significant (r = 0.14 (95% CI, -0.03 to 0.29), P = 0.097), and that between gestational age and OA-PSV ratio was weak (r = -0.23 (95% CI, -0.38 to -0.07), P = 0.004), as opposed to the strong correlation between gestational age and UtA-PI (r = -0.68 (95% CI, -0.76 to -0.58), P < 0.001). No strong correlations were observed between OA-PI or OA-PSV ratio and maternal hemodynamic indices. The correlations were unaltered by adjustment for maternal age and body mass index. The intraobserver reproducibility of OA-PI and OA-PSV ratio in the same eye was high. The correlation between the right and left eyes was moderate for OA-PI (r = 0.63 (95% CI, 0.53-0.72), P < 0.001) and strong for OA-PSV ratio (r = 0.81 (95% CI, 0.75-0.86), P < 0.001).</p><p><strong>Conclusions: </strong>OA-PI and OA-PSV ratio had a weak or no correlation with UtA-PI and maternal hemodynamic parameters, meaning that they can be used as independent predictors for pre-eclampsia. Gestational age had no clinically relevant effect on OA-PI and OA-PSV ratio, suggesting that these indices could be measured without adjustment at any time between 11 and 23 weeks' gestation. OA Doppler indices had high intraobserver reproducibility and were strongly correlated between the right and left eyes. © 2025 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.</p>","PeriodicalId":23454,"journal":{"name":"Ultrasound in Obstetrics & Gynecology","volume":" ","pages":"163-172"},"PeriodicalIF":6.1000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11788460/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound in Obstetrics & Gynecology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/uog.29162","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/20 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To examine the relationship of ophthalmic artery (OA) Doppler indices with uterine artery (UtA) Doppler indices, selected maternal hemodynamic parameters and gestational age, and to evaluate the intraobserver reproducibility of OA Doppler indices.

Methods: This was a prospective cohort study of women recruited between 11 + 0 and 23 + 6 weeks' gestation using a stratified and random sampling approach to ensure adequate distribution across the gestational-age range. OA pulsatility index (PI), first peak systolic velocity (PSV1), second peak systolic velocity (PSV2) and peak systolic velocity ratio (PSV ratio), calculated as PSV2/PSV1, were measured twice in each eye by the same observer. UtA-PI was also measured twice on each side by the same observer. Maternal hemodynamic assessment was undertaken using an ultrasonic cardiac output monitor (USCOM 1A). Pearson's and Spearman's rank correlation coefficients were used to assess the correlations between variables, and Bland-Altman plots were used to evaluate the intraobserver reproducibility of OA Doppler indices.

Results: Of 194 women invited to participate in the study, 169 were eligible for inclusion, of whom 16 were excluded following an obstetric ultrasound scan and a further three owing to inadequate or incomplete OA or UtA Doppler assessment, leaving 150 women in the final analysis. Log UtA-PI had a weak correlation with both OA-PI (r = -0.19 (95% CI, -0.34 to -0.03), P = 0.021) and OA-PSV ratio (r = 0.31 (95% CI, 0.15-0.45), P < 0.001). The correlation between gestational age and OA-PI was non-significant (r = 0.14 (95% CI, -0.03 to 0.29), P = 0.097), and that between gestational age and OA-PSV ratio was weak (r = -0.23 (95% CI, -0.38 to -0.07), P = 0.004), as opposed to the strong correlation between gestational age and UtA-PI (r = -0.68 (95% CI, -0.76 to -0.58), P < 0.001). No strong correlations were observed between OA-PI or OA-PSV ratio and maternal hemodynamic indices. The correlations were unaltered by adjustment for maternal age and body mass index. The intraobserver reproducibility of OA-PI and OA-PSV ratio in the same eye was high. The correlation between the right and left eyes was moderate for OA-PI (r = 0.63 (95% CI, 0.53-0.72), P < 0.001) and strong for OA-PSV ratio (r = 0.81 (95% CI, 0.75-0.86), P < 0.001).

Conclusions: OA-PI and OA-PSV ratio had a weak or no correlation with UtA-PI and maternal hemodynamic parameters, meaning that they can be used as independent predictors for pre-eclampsia. Gestational age had no clinically relevant effect on OA-PI and OA-PSV ratio, suggesting that these indices could be measured without adjustment at any time between 11 and 23 weeks' gestation. OA Doppler indices had high intraobserver reproducibility and were strongly correlated between the right and left eyes. © 2025 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

母眼动脉多普勒与子宫动脉多普勒、血流动力学指标及胎龄的关系:前瞻性MATERA研究。
目的:探讨眼动脉(OA)多普勒指数与子宫动脉(UtA)多普勒指数、选定的母体血流动力学参数及胎龄的关系,并评价眼动脉(OA)多普勒指数在观察时的再现性。方法:这是一项前瞻性队列研究,采用分层和随机抽样方法招募妊娠11 + 0至23 + 6周的妇女,以确保在整个胎龄范围内充分分布。同一观测者每只眼测量两次OA脉搏指数(PI)、第一收缩压峰值速度(PSV1)、第二收缩压峰值速度(PSV2)和收缩压峰值速度比(PSV ratio),计算方法为PSV2/PSV1。UtA-PI也由同一观测者在每侧测量两次。使用超声心输出量监测仪(USCOM 1A)进行母体血流动力学评估。Pearson's和Spearman's秩相关系数用于评估变量之间的相关性,Bland-Altman图用于评估OA多普勒指数的观察者内再现性。结果:在194名受邀参加研究的女性中,169名符合纳入条件,其中16名因产科超声扫描而被排除,另外3名因OA或UtA多普勒评估不充分或不完整而被排除,最终分析剩下150名女性。Log UtA-PI与OA-PI (r = -0.19 (95% CI, -0.34 ~ -0.03), P = 0.021)和OA-PSV比值(r = 0.31 (95% CI, 0.15 ~ 0.45), P均呈弱相关。结论:OA-PI和OA-PSV比值与UtA-PI和母体血流动力学参数相关性较弱或无相关性,可作为子痫前期的独立预测指标。胎龄对OA-PI和OA-PSV比值无临床相关影响,提示在妊娠11 ~ 23周的任何时间均可测量这些指标,无需调整。OA多普勒指数具有较高的观察者内再现性,且右眼和左眼之间具有很强的相关性。©2025作者。妇产科学超声由John Wiley & Sons Ltd代表国际妇产科学超声学会出版。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
12.30
自引率
14.10%
发文量
891
审稿时长
1 months
期刊介绍: Ultrasound in Obstetrics & Gynecology (UOG) is the official journal of the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) and is considered the foremost international peer-reviewed journal in the field. It publishes cutting-edge research that is highly relevant to clinical practice, which includes guidelines, expert commentaries, consensus statements, original articles, and systematic reviews. UOG is widely recognized and included in prominent abstract and indexing databases such as Index Medicus and Current Contents.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信