Michael Ting, Garry McDermott, Amir Zarei, Chirag Patel, Fahmid U Chowdhury, Andreia Rodrigues, Andrew F Scarsbrook
{"title":"Qualitative and quantitative analysis of reduced bed position acquisition time on FDG PET image quality.","authors":"Michael Ting, Garry McDermott, Amir Zarei, Chirag Patel, Fahmid U Chowdhury, Andreia Rodrigues, Andrew F Scarsbrook","doi":"10.1097/MNM.0000000000001957","DOIUrl":null,"url":null,"abstract":"<p><p>The study aim was to evaluate whether reducing bed position acquisition time would result in significant detriment to image quality. Secondary aims were to compare effect of time of flight (TOF) and Q.Clear reconstructions and patient BMI on image quality. Fluorodeoxyglucose PET-CT performed in 30 patients on a new scanner at our institution between March and May 2024 was retrospectively evaluated. Four PET reconstructions were performed: (a) 1 min 45 s TOF, (b) 2 min TOF, (c) 1 min 45 s Q.Clear, and (d) 2 min Q.Clear. For qualitative analysis, four maximum intensity projection images were evaluated side-by-side using a five-point visual score (1 = non-diagnostic, 5 = excellent). For quantitative analysis, liver signal-to-noise ratio (SNR) was calculated. A statistically significant reduction in visual score occurred when reducing bed position time from 2 min to 1 min 45 s (mean TOF scores 0.24 reduction, P = 0.0002; mean Q.Clear scores 0.04 reduction, P = 0.02. There was also a statistically significant difference in liver SNR when reducing bed position time. Deterioration in image quality was minimised when bed position acquisition time was reduced if Q.Clear construction was utilized. This could facilitate increased scanning capacity without clinical detriment.</p>","PeriodicalId":19708,"journal":{"name":"Nuclear Medicine Communications","volume":" ","pages":"362-366"},"PeriodicalIF":1.3000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11878577/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Medicine Communications","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MNM.0000000000001957","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/21 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
The study aim was to evaluate whether reducing bed position acquisition time would result in significant detriment to image quality. Secondary aims were to compare effect of time of flight (TOF) and Q.Clear reconstructions and patient BMI on image quality. Fluorodeoxyglucose PET-CT performed in 30 patients on a new scanner at our institution between March and May 2024 was retrospectively evaluated. Four PET reconstructions were performed: (a) 1 min 45 s TOF, (b) 2 min TOF, (c) 1 min 45 s Q.Clear, and (d) 2 min Q.Clear. For qualitative analysis, four maximum intensity projection images were evaluated side-by-side using a five-point visual score (1 = non-diagnostic, 5 = excellent). For quantitative analysis, liver signal-to-noise ratio (SNR) was calculated. A statistically significant reduction in visual score occurred when reducing bed position time from 2 min to 1 min 45 s (mean TOF scores 0.24 reduction, P = 0.0002; mean Q.Clear scores 0.04 reduction, P = 0.02. There was also a statistically significant difference in liver SNR when reducing bed position time. Deterioration in image quality was minimised when bed position acquisition time was reduced if Q.Clear construction was utilized. This could facilitate increased scanning capacity without clinical detriment.
研究的目的是评估减少床位置获取时间是否会对图像质量造成重大损害。次要目的是比较飞行时间(TOF)和q .清晰度重建和患者BMI对图像质量的影响。回顾性评价2024年3月至5月在我院新扫描仪上对30例患者进行的氟脱氧葡萄糖PET-CT检查。进行四次PET重建:(a) 1 min 45 s TOF, (b) 2 min TOF, (c) 1 min 45 s Q.Clear, (d) 2 min Q.Clear。为了进行定性分析,使用5分视觉评分(1 =非诊断性,5 =优秀)并排评估4个最大强度投影图像。为了进行定量分析,计算肝脏的信噪比(SNR)。当床位时间从2分钟减少到1分钟45秒时,视觉评分有统计学意义的降低(平均TOF评分降低0.24,P = 0.0002;clear评分降低0.04,P = 0.02。缩短床位时间后,肝脏信噪比差异也有统计学意义。如果使用Q.Clear构造,当床位获取时间减少时,图像质量的恶化将最小化。这可以在不损害临床的情况下提高扫描能力。
期刊介绍:
Nuclear Medicine Communications, the official journal of the British Nuclear Medicine Society, is a rapid communications journal covering nuclear medicine and molecular imaging with radionuclides, and the basic supporting sciences. As well as clinical research and commentary, manuscripts describing research on preclinical and basic sciences (radiochemistry, radiopharmacy, radiobiology, radiopharmacology, medical physics, computing and engineering, and technical and nursing professions involved in delivering nuclear medicine services) are welcomed, as the journal is intended to be of interest internationally to all members of the many medical and non-medical disciplines involved in nuclear medicine. In addition to papers reporting original studies, frankly written editorials and topical reviews are a regular feature of the journal.