Jacopo Saccomanno, Lara Kilic, Thomas Sgarbossa, Konrad Neumann, Franz Stanzel, Angelique Holland, Christian Grah, Wolfgang Gesierich, Joanna Krist, Joachim H Ficker, Stephan Eggeling, Stefan Andreas, Bernd Schmidt, Stephan Eisenmann, Björn Schwick, Karl-Josef Franke, Andreas Fertl, Martin Witzenrath, Ralf-Harto Hübner
{"title":"Clinical improvements after endoscopic lung volume reduction with valves in patients with advanced emphysema and a 6-min walk test ≤140 m at baseline.","authors":"Jacopo Saccomanno, Lara Kilic, Thomas Sgarbossa, Konrad Neumann, Franz Stanzel, Angelique Holland, Christian Grah, Wolfgang Gesierich, Joanna Krist, Joachim H Ficker, Stephan Eggeling, Stefan Andreas, Bernd Schmidt, Stephan Eisenmann, Björn Schwick, Karl-Josef Franke, Andreas Fertl, Martin Witzenrath, Ralf-Harto Hübner","doi":"10.1183/23120541.00410-2024","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Data regarding the effectiveness and safety of endoscopic lung volume reduction with valves (ELVR) in emphysema patients with a very low 6-min walk test (6MWT) are limited. Patients with severe emphysema and very low exercise capacity, as indicated by a 6MWT ≤140 m, are often excluded from clinical studies on ELVR, assuming limited therapeutic benefits and increased complication risk.</p><p><strong>Study designs and methods: </strong>This study utilised data from the Lungenemphysemregister e.V., a large German national multi-centre prospective open-label clinical trial, and aimed to assess the outcomes of ELVR in patients with a baseline 6MWT ≤140 m and dyspnoea primarily attributed to hyperinflation.</p><p><strong>Results: </strong>54 patients with a baseline 6MWT ≤140 m and 365 patients with a baseline 6MWT between 140 and 450 m were included in the study. Baseline characteristics were representative for patients with advanced lung emphysema. Patients with a 6MWT ≤140 m at baseline had a lower forced expiratory volume in 1 s and diffusing capacity of the lung for carbon monoxide and higher symptom burden. In the 3-month follow-up, patients of both groups showed statistically significant improvements in lung function parameters, exercise capacity and quality of life parameters compared to baseline. Patients with a 6MWT ≤140 m at baseline showed significantly more 6MWT improvement compared to patients with baseline 6MWT between 140 and 450 m. Moreover, complication rates were similar in both groups.</p><p><strong>Interpretation: </strong>In summary, the data indicate that ELVR may be an effective and safe treatment for emphysema patients with a very low 6MWT of ≤140 m if very limited exercise capacity is predominately caused by lung emphysema. Therefore future studies should include emphysema patients with a very low 6MWT.</p>","PeriodicalId":11739,"journal":{"name":"ERJ Open Research","volume":"11 1","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2025-01-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11726540/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ERJ Open Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1183/23120541.00410-2024","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Data regarding the effectiveness and safety of endoscopic lung volume reduction with valves (ELVR) in emphysema patients with a very low 6-min walk test (6MWT) are limited. Patients with severe emphysema and very low exercise capacity, as indicated by a 6MWT ≤140 m, are often excluded from clinical studies on ELVR, assuming limited therapeutic benefits and increased complication risk.
Study designs and methods: This study utilised data from the Lungenemphysemregister e.V., a large German national multi-centre prospective open-label clinical trial, and aimed to assess the outcomes of ELVR in patients with a baseline 6MWT ≤140 m and dyspnoea primarily attributed to hyperinflation.
Results: 54 patients with a baseline 6MWT ≤140 m and 365 patients with a baseline 6MWT between 140 and 450 m were included in the study. Baseline characteristics were representative for patients with advanced lung emphysema. Patients with a 6MWT ≤140 m at baseline had a lower forced expiratory volume in 1 s and diffusing capacity of the lung for carbon monoxide and higher symptom burden. In the 3-month follow-up, patients of both groups showed statistically significant improvements in lung function parameters, exercise capacity and quality of life parameters compared to baseline. Patients with a 6MWT ≤140 m at baseline showed significantly more 6MWT improvement compared to patients with baseline 6MWT between 140 and 450 m. Moreover, complication rates were similar in both groups.
Interpretation: In summary, the data indicate that ELVR may be an effective and safe treatment for emphysema patients with a very low 6MWT of ≤140 m if very limited exercise capacity is predominately caused by lung emphysema. Therefore future studies should include emphysema patients with a very low 6MWT.
期刊介绍:
ERJ Open Research is a fully open access original research journal, published online by the European Respiratory Society. The journal aims to publish high-quality work in all fields of respiratory science and medicine, covering basic science, clinical translational science and clinical medicine. The journal was created to help fulfil the ERS objective to disseminate scientific and educational material to its members and to the medical community, but also to provide researchers with an affordable open access specialty journal in which to publish their work.