Leadless Pacemaker vs. Transvenous Pacemaker in End Stage Kidney Disease: Insights from the Nationwide Readmission Database.

IF 3 3区 医学 Q1 MEDICINE, GENERAL & INTERNAL
Sajog Kansakar, Azka Naeem, Norbert Moskovits, Dhan Bahadur Shrestha, Jurgen Shtembari, Monodeep Biswas, Ghanshyam Shantha, Binaya Basyal, James Storey, Daniel Katz
{"title":"Leadless Pacemaker vs. Transvenous Pacemaker in End Stage Kidney Disease: Insights from the Nationwide Readmission Database.","authors":"Sajog Kansakar, Azka Naeem, Norbert Moskovits, Dhan Bahadur Shrestha, Jurgen Shtembari, Monodeep Biswas, Ghanshyam Shantha, Binaya Basyal, James Storey, Daniel Katz","doi":"10.3390/jcm14010202","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background</b>: Leadless pacemakers offer a safe and effective alternative pacing strategy. However, limited data are available for patients with end stage renal disease (ESRD), a population of significant relevance. <b>Methods:</b> Using the Nationwide Readmission Database, we extracted data from all adult patients with ESRD who underwent traditional transvenous or leadless pacemaker implantation between 2016 and 2021. We compared in-hospital mortality, 30-day readmission rates, complication rates, and healthcare resource utilization between the two cohorts. <b>Results:</b> A total of 6384 (81.2%) patients were included in the transvenous pacemaker cohort, and 1481(18.8%) patients were included in the leadless pacemaker cohort. In patients with ESRD, leadless pacemaker implantation was linked to higher in-hospital complications when compared to transvenous pacemakers. These included the need for blood transfusion (aOR 1.85, 95% CI 1.32-2.60, <i>p</i> < 0.01), vascular complications (aOR 3.6, CI 1.40-9.26, <i>p</i> = 0.01), and cardiac complications (aOR 4.12, CI 1.70-9.98, <i>p</i> < 0.01). However, there were no differences between the two groups in terms of in-hospital mortality and 30-day readmission rates. The median length of stay was longer for leadless pacemaker implantation than transvenous pacemaker implantation (5 days vs. 4 days, <i>p</i> < 0.01). The total hospitalization charges were also higher ($139,826 vs. $93,919, <i>p</i> < 0.01). <b>Conclusions:</b> Although previous studies have demonstrated lower long-term complication rates with leadless pacemakers than transvenous pacemakers, our analysis shows a higher risk of short-term in-hospital complications in ESRD patients, though no differences in in-hospital mortality and 30-day readmissions.</p>","PeriodicalId":15533,"journal":{"name":"Journal of Clinical Medicine","volume":"14 1","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11721035/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/jcm14010202","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Leadless pacemakers offer a safe and effective alternative pacing strategy. However, limited data are available for patients with end stage renal disease (ESRD), a population of significant relevance. Methods: Using the Nationwide Readmission Database, we extracted data from all adult patients with ESRD who underwent traditional transvenous or leadless pacemaker implantation between 2016 and 2021. We compared in-hospital mortality, 30-day readmission rates, complication rates, and healthcare resource utilization between the two cohorts. Results: A total of 6384 (81.2%) patients were included in the transvenous pacemaker cohort, and 1481(18.8%) patients were included in the leadless pacemaker cohort. In patients with ESRD, leadless pacemaker implantation was linked to higher in-hospital complications when compared to transvenous pacemakers. These included the need for blood transfusion (aOR 1.85, 95% CI 1.32-2.60, p < 0.01), vascular complications (aOR 3.6, CI 1.40-9.26, p = 0.01), and cardiac complications (aOR 4.12, CI 1.70-9.98, p < 0.01). However, there were no differences between the two groups in terms of in-hospital mortality and 30-day readmission rates. The median length of stay was longer for leadless pacemaker implantation than transvenous pacemaker implantation (5 days vs. 4 days, p < 0.01). The total hospitalization charges were also higher ($139,826 vs. $93,919, p < 0.01). Conclusions: Although previous studies have demonstrated lower long-term complication rates with leadless pacemakers than transvenous pacemakers, our analysis shows a higher risk of short-term in-hospital complications in ESRD patients, though no differences in in-hospital mortality and 30-day readmissions.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Clinical Medicine
Journal of Clinical Medicine MEDICINE, GENERAL & INTERNAL-
CiteScore
5.70
自引率
7.70%
发文量
6468
审稿时长
16.32 days
期刊介绍: Journal of Clinical Medicine (ISSN 2077-0383), is an international scientific open access journal, providing a platform for advances in health care/clinical practices, the study of direct observation of patients and general medical research. This multi-disciplinary journal is aimed at a wide audience of medical researchers and healthcare professionals. Unique features of this journal: manuscripts regarding original research and ideas will be particularly welcomed.JCM also accepts reviews, communications, and short notes. There is no limit to publication length: our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信