Sourav Podder, Scott Cowan, Scott Koeneman, Elizabeth Pavis, Doo Park, Christine Schleider, Kathleen Shindle, Matthew Bowen, Adam Johnson
{"title":"Resident-Driven Guideline to Reduce Iatrogenic Pneumothoraxes From Small-Bore Feeding Tubes: A Quality and Safety Improvement Project.","authors":"Sourav Podder, Scott Cowan, Scott Koeneman, Elizabeth Pavis, Doo Park, Christine Schleider, Kathleen Shindle, Matthew Bowen, Adam Johnson","doi":"10.1097/JMQ.0000000000000215","DOIUrl":null,"url":null,"abstract":"<p><p>Small-bore feeding tubes (SBFT) in vulnerable patients carry a risk of iatrogenic pneumothorax by misplacement into the lung. This institution noted a series of iatrogenic pneumothoraxes caused by the placement of these devices. A resident-led, multidisciplinary team developed a hospital guideline through a consensus-driven process. The guideline mandated SBFT placement by approved \"super-users\" via the CORTRAK Enteral Access System or via non-CORTRAK Methods, including the 2-step X-ray Method, fluoroscopy, or direct visualization techniques. A \"super-user\" Program for the CORTRAK Enteral Access System was developed to assure competency and consistency. With the development of the guideline and \"super-user\" program, the authors observed a decrease in the number of SBFT-related iatrogenic pneumothoraxes. Following a brief period of adoption, the three-hospital organization has had no SBFT-related iatrogenic pneumothoraxes. This project demonstrates the effectiveness of developing a resident-driven, evidence-based hospital guideline for the safe passage of SBFTs.</p>","PeriodicalId":101338,"journal":{"name":"American journal of medical quality : the official journal of the American College of Medical Quality","volume":" ","pages":"8-14"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of medical quality : the official journal of the American College of Medical Quality","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/JMQ.0000000000000215","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/10 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Small-bore feeding tubes (SBFT) in vulnerable patients carry a risk of iatrogenic pneumothorax by misplacement into the lung. This institution noted a series of iatrogenic pneumothoraxes caused by the placement of these devices. A resident-led, multidisciplinary team developed a hospital guideline through a consensus-driven process. The guideline mandated SBFT placement by approved "super-users" via the CORTRAK Enteral Access System or via non-CORTRAK Methods, including the 2-step X-ray Method, fluoroscopy, or direct visualization techniques. A "super-user" Program for the CORTRAK Enteral Access System was developed to assure competency and consistency. With the development of the guideline and "super-user" program, the authors observed a decrease in the number of SBFT-related iatrogenic pneumothoraxes. Following a brief period of adoption, the three-hospital organization has had no SBFT-related iatrogenic pneumothoraxes. This project demonstrates the effectiveness of developing a resident-driven, evidence-based hospital guideline for the safe passage of SBFTs.