Seyed Arman Moein, Javad Dehghani, Reza Fereidooni, Mohammad Hadi Gerami, Asal Seifaei, Seyyed Hamidreza Ayatizadeh
{"title":"Short-term outcomes of gradual ulnar lengthening in multiple hereditary osteochondromas of the forearm with monolateral external fixator.","authors":"Seyed Arman Moein, Javad Dehghani, Reza Fereidooni, Mohammad Hadi Gerami, Asal Seifaei, Seyyed Hamidreza Ayatizadeh","doi":"10.1097/BPB.0000000000001232","DOIUrl":null,"url":null,"abstract":"<p><p>Hereditary multiple exostoses is an autosomal dominant genetic condition primarily affecting long bones. Forearm deformities, including wrist ulnar deviation, ulnar shortening, radial or ulnar bowing, and radial head dislocation, are common manifestations. Gradual ulnar lengthening is suggested as a viable treatment option for managing these deformities. This retrospective single-center study included 15 forearms treated with gradual ulnar lengthening using a monolateral external fixator by a single surgeon. Clinical and radiological characteristics were recorded preoperatively and during follow-ups. The Wilcoxon signed-rank test compared preoperative and postoperative radiological and clinical parameters, while McNemar's test assessed changes in radial head dislocation or subluxation. Significant radiological improvements were observed post-treatment. Proportional ulnar length increased from a mean of 0.85 ± 0.10 preoperatively to 1.11 ± 0.03 at the last follow-up (P < 0.001). Ulnar variance decreased from a mean of 17.6 ± 5.58 mm preoperatively to 0.13 ± 1.81 mm at the last follow-up (P < 0.001), while radial bowing decreased from a mean of 0.06 ± 0.02 to 0.05 ± 0.01 at the last follow-up (P < 0.001). In addition, the radioarticular angle decreased significantly from a mean of 29.93 ± 7.34 to 20.20 ± 5.71° (P < 0.001). The incidence of radial head dislocation or subluxation decreased significantly, from 11 patients preoperatively to only one at the last follow-up. These findings demonstrate the effectiveness of gradual ulnar lengthening with a monolateral external fixator in correcting forearm deformities and reducing the incidence of radial head dislocation or subluxation.</p>","PeriodicalId":50092,"journal":{"name":"Journal of Pediatric Orthopaedics-Part B","volume":" ","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2025-01-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pediatric Orthopaedics-Part B","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/BPB.0000000000001232","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Hereditary multiple exostoses is an autosomal dominant genetic condition primarily affecting long bones. Forearm deformities, including wrist ulnar deviation, ulnar shortening, radial or ulnar bowing, and radial head dislocation, are common manifestations. Gradual ulnar lengthening is suggested as a viable treatment option for managing these deformities. This retrospective single-center study included 15 forearms treated with gradual ulnar lengthening using a monolateral external fixator by a single surgeon. Clinical and radiological characteristics were recorded preoperatively and during follow-ups. The Wilcoxon signed-rank test compared preoperative and postoperative radiological and clinical parameters, while McNemar's test assessed changes in radial head dislocation or subluxation. Significant radiological improvements were observed post-treatment. Proportional ulnar length increased from a mean of 0.85 ± 0.10 preoperatively to 1.11 ± 0.03 at the last follow-up (P < 0.001). Ulnar variance decreased from a mean of 17.6 ± 5.58 mm preoperatively to 0.13 ± 1.81 mm at the last follow-up (P < 0.001), while radial bowing decreased from a mean of 0.06 ± 0.02 to 0.05 ± 0.01 at the last follow-up (P < 0.001). In addition, the radioarticular angle decreased significantly from a mean of 29.93 ± 7.34 to 20.20 ± 5.71° (P < 0.001). The incidence of radial head dislocation or subluxation decreased significantly, from 11 patients preoperatively to only one at the last follow-up. These findings demonstrate the effectiveness of gradual ulnar lengthening with a monolateral external fixator in correcting forearm deformities and reducing the incidence of radial head dislocation or subluxation.
期刊介绍:
The journal highlights important recent developments from the world''s leading clinical and research institutions. The journal publishes peer-reviewed papers on the diagnosis and treatment of pediatric orthopedic disorders.
It is the official journal of IFPOS (International Federation of Paediatric Orthopaedic Societies).
Submitted articles undergo a preliminary review by the editor. Some articles may be returned to authors without further consideration. Those being considered for publication will undergo further assessment and peer-review by the editors and those invited to do so from a reviewer pool.