Yousef Hussein, Afrim Iljazi, Michala S Sørensen, Søren Overgaard, Michael M Petersen
{"title":"The risk of dislocation in dual-mobility versus 36 mm heads in primary total hip arthroplasty for osteoarthritis.","authors":"Yousef Hussein, Afrim Iljazi, Michala S Sørensen, Søren Overgaard, Michael M Petersen","doi":"10.1302/0301-620X.107B1.BJJ-2024-0611.R1","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Dislocation is a major concern following total hip arthroplasty (THA) for osteoarthritis (OA). Both dual-mobility components and standard acetabular components with large femoral heads are used to reduce the risk of dislocation. We investigated whether dual-mobility components are superior to standard components in reducing the two-year dislocation and revision risk in a propensity-matched sample from the Danish Hip Arthroplasty Register (DHR).</p><p><strong>Methods: </strong>This population-based cohort study analyzed data from the DHR and the Danish National Patient Register. We included all patients undergoing primary THA for OA from January 2010 to December 2019 with either dual-mobility or standard acetabular components with metal-on-polyethylene or ceramic-on-polyethylene articulations with a 36 mm femoral head. The samples were propensity score-matched on patient and implant characteristics. The primary outcome was the difference in the absolute risk of dislocation within two years, with a secondary outcome of the difference in the absolute risk of revision surgery of any cause within the same timeframe. The cumulative incidence of dislocation was calculated using the Aalen-Johansen estimator, while the difference in absolute risk was estimated using absolute risk regression (ARR).</p><p><strong>Results: </strong>We included 4,499 patients with dual-mobility components and 4,499 patients with standard components after propensity score-matching. Both groups had a mean age of 75 years (SD 8.5), included approximately 60% females, and had a two-year survival of 95.3% (95% CI 94.6 to 95.9). The dual-mobility group was 80% less likely to dislocate within two years (ARR 0.20 (95% CI 0.14 to 0.28); p < 0.001), with no significant difference in the risk of revision compared to standard components (ARR 1.15 (95% CI 0.89 to 1.48); p = 0.293).</p><p><strong>Conclusion: </strong>Dual-mobility components are associated with a reduced risk of dislocation and with no significant difference in the risk of revision for any cause within two years of THA when compared to standard acetabular components with 36 mm femoral heads.</p>","PeriodicalId":48944,"journal":{"name":"Bone & Joint Journal","volume":"107-B 1","pages":"50-57"},"PeriodicalIF":4.9000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bone & Joint Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1302/0301-620X.107B1.BJJ-2024-0611.R1","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Aims: Dislocation is a major concern following total hip arthroplasty (THA) for osteoarthritis (OA). Both dual-mobility components and standard acetabular components with large femoral heads are used to reduce the risk of dislocation. We investigated whether dual-mobility components are superior to standard components in reducing the two-year dislocation and revision risk in a propensity-matched sample from the Danish Hip Arthroplasty Register (DHR).
Methods: This population-based cohort study analyzed data from the DHR and the Danish National Patient Register. We included all patients undergoing primary THA for OA from January 2010 to December 2019 with either dual-mobility or standard acetabular components with metal-on-polyethylene or ceramic-on-polyethylene articulations with a 36 mm femoral head. The samples were propensity score-matched on patient and implant characteristics. The primary outcome was the difference in the absolute risk of dislocation within two years, with a secondary outcome of the difference in the absolute risk of revision surgery of any cause within the same timeframe. The cumulative incidence of dislocation was calculated using the Aalen-Johansen estimator, while the difference in absolute risk was estimated using absolute risk regression (ARR).
Results: We included 4,499 patients with dual-mobility components and 4,499 patients with standard components after propensity score-matching. Both groups had a mean age of 75 years (SD 8.5), included approximately 60% females, and had a two-year survival of 95.3% (95% CI 94.6 to 95.9). The dual-mobility group was 80% less likely to dislocate within two years (ARR 0.20 (95% CI 0.14 to 0.28); p < 0.001), with no significant difference in the risk of revision compared to standard components (ARR 1.15 (95% CI 0.89 to 1.48); p = 0.293).
Conclusion: Dual-mobility components are associated with a reduced risk of dislocation and with no significant difference in the risk of revision for any cause within two years of THA when compared to standard acetabular components with 36 mm femoral heads.
期刊介绍:
We welcome original articles from any part of the world. The papers are assessed by members of the Editorial Board and our international panel of expert reviewers, then either accepted for publication or rejected by the Editor. We receive over 2000 submissions each year and accept about 250 for publication, many after revisions recommended by the reviewers, editors or statistical advisers. A decision usually takes between six and eight weeks. Each paper is assessed by two reviewers with a special interest in the subject covered by the paper, and also by members of the editorial team. Controversial papers will be discussed at a full meeting of the Editorial Board. Publication is between four and six months after acceptance.