Addressing Medical Device Extractables and Leachables via Non-Target Analysis (NTA); The Analytical Evaluation Threshold (AET) and Quantitation.

Q3 Medicine
Dennis Jenke, Piet Christiaens, Ted Heise
{"title":"Addressing Medical Device Extractables and Leachables via Non-Target Analysis (NTA); The Analytical Evaluation Threshold (AET) and Quantitation.","authors":"Dennis Jenke, Piet Christiaens, Ted Heise","doi":"10.5731/pdajpst.2024.012945","DOIUrl":null,"url":null,"abstract":"<p><p>Leachables leached from a medical device during its clinical use are important due to the patient health-related effects they may have. Thus, medical devices are profiled for leachables (and/or extractables as probable leachables) by screening extracts or leachates of the medical device for released organic substances via non-targeted analysis (NTA) employing chromatographic methods coupled with mass spectrometric detection. Chromatographic mass spectral response factors for extractables and leachables vary significantly from compound to compound, complicating the application of assessment strategies such as the Analytical Evaluation Threshold (AET), which is the concentration threshold at or above which an extractable or leachable must be reported for quantitative toxicological risk assessment. The analytical uncertainty resulting from response variation can make interpretation of the AET difficult, potentially leading to both false positive and false negative outcomes. Furthermore, response factor variation complicates the estimation of leachables' and extractables' concentrations (quantification). This Correspondence discusses best practice recommendations for the calculation and application of the AET and for performing quantification, including a discussion of accuracy versus protectiveness.</p>","PeriodicalId":19986,"journal":{"name":"PDA Journal of Pharmaceutical Science and Technology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-12-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"PDA Journal of Pharmaceutical Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5731/pdajpst.2024.012945","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Leachables leached from a medical device during its clinical use are important due to the patient health-related effects they may have. Thus, medical devices are profiled for leachables (and/or extractables as probable leachables) by screening extracts or leachates of the medical device for released organic substances via non-targeted analysis (NTA) employing chromatographic methods coupled with mass spectrometric detection. Chromatographic mass spectral response factors for extractables and leachables vary significantly from compound to compound, complicating the application of assessment strategies such as the Analytical Evaluation Threshold (AET), which is the concentration threshold at or above which an extractable or leachable must be reported for quantitative toxicological risk assessment. The analytical uncertainty resulting from response variation can make interpretation of the AET difficult, potentially leading to both false positive and false negative outcomes. Furthermore, response factor variation complicates the estimation of leachables' and extractables' concentrations (quantification). This Correspondence discusses best practice recommendations for the calculation and application of the AET and for performing quantification, including a discussion of accuracy versus protectiveness.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.90
自引率
0.00%
发文量
34
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信