{"title":"Proactive esophageal cooling during radiofrequency cardiac ablation: data update including applications in very high-power short duration ablation.","authors":"Tiffany Sharkoski, Jason Zagrodzky, Nikhil Warrier, Rahul Doshi, Samuel Omotoye, Marcela Mercado Montoya, Tatiana Gómez Bustamante, Enrique Berjano, Ana González Suárez, Erik Kulstad, Mark Metzl","doi":"10.1080/17434440.2024.2447809","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Proactive esophageal cooling reduces injury during radiofrequency (RF) ablation of the left atrium (LA) for the treatment of atrial fibrillation (AF). New catheters are capable of higher wattage settings up to 90 W (very high-power short duration, vHPSD) for 4s. Varying power and duration however does not eliminate the risk of thermal injury. Furthermore, alternative energy sources such as pulsed field ablation (PFA) also exhibit thermal effects, with clinical data showing esophageal temperatures up to 40.3°C. The ensoETM esophageal cooling device (Attune Medical, now a part of Haemonetics, Boston, MA, U.S.A.) is commercially available and FDA-cleared to reduce thermal injury to the esophagus during RF ablation for AF and is recommended in the 2024 expert consensus statement on catheter and surgical ablation of AF.</p><p><strong>Areas covered: </strong>This review summarizes growing evidence of esophageal cooling during high power RF ablation for AF treatment, including data relating to procedural efficacy, safety, and efficiency, and techniques to enhance operator success while providing directions for further research.</p><p><strong>Expert opinion: </strong>Proactive esophageal cooling reduces injury to the esophagus during high power RF ablation, and utilizing this approach may result in increased success in first-pass.</p>","PeriodicalId":94006,"journal":{"name":"Expert review of medical devices","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-12-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert review of medical devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/17434440.2024.2447809","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Proactive esophageal cooling reduces injury during radiofrequency (RF) ablation of the left atrium (LA) for the treatment of atrial fibrillation (AF). New catheters are capable of higher wattage settings up to 90 W (very high-power short duration, vHPSD) for 4s. Varying power and duration however does not eliminate the risk of thermal injury. Furthermore, alternative energy sources such as pulsed field ablation (PFA) also exhibit thermal effects, with clinical data showing esophageal temperatures up to 40.3°C. The ensoETM esophageal cooling device (Attune Medical, now a part of Haemonetics, Boston, MA, U.S.A.) is commercially available and FDA-cleared to reduce thermal injury to the esophagus during RF ablation for AF and is recommended in the 2024 expert consensus statement on catheter and surgical ablation of AF.

Areas covered: This review summarizes growing evidence of esophageal cooling during high power RF ablation for AF treatment, including data relating to procedural efficacy, safety, and efficiency, and techniques to enhance operator success while providing directions for further research.

Expert opinion: Proactive esophageal cooling reduces injury to the esophagus during high power RF ablation, and utilizing this approach may result in increased success in first-pass.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信