{"title":"Complications of electrosurgery: mechanisms and prevention strategies.","authors":"S M El-Sayed, E Saridogan, M M El-Sayed","doi":"10.52054/FVVO.16.4.048","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Electrosurgery is widely used in all surgical specialities. There is evidence that surgeons in different disciplines and with different experience levels have an inadequate understanding of the basics of electrosurgery and its complications. This can increase the risk of electrosurgical complications. Despite its improved safety technology, electrosurgery is still associated with serious morbidity and mortality. In addition, such adverse outcomes will incur financial losses to our health system due to the costs of repeated operations, prolonged hospital stays, and litigation.</p><p><strong>Objectives: </strong>To identify the various mechanisms of electrosurgical complications and to highlight the recommended actions to prevent such complications.</p><p><strong>Materials and methods: </strong>Narrative review based on a literature search of the Medline database using the following search terms: \"electrosurgery\", \"complications\", \"risks\", and \"adverse effects\", with further citation searching for related articles.</p><p><strong>Main outcome measures and results: </strong>The paper does not address specific research questions but addresses common knowledge gaps in the mechanisms of electrosurgical complications among surgeons.</p><p><strong>Conclusions: </strong>Electrosurgical devices can cause severe complications such as unintended tissue burns, surgical fires, smoke hazards, and interference with implantable devices. Although such energy devices are designed with increasingly improving safety features, an adequate understanding of the circumstances, mechanisms, and prevention of these complications by the surgical team is the cornerstone in mitigating such risks.</p>","PeriodicalId":46400,"journal":{"name":"Facts Views and Vision in ObGyn","volume":"16 4","pages":"473-484"},"PeriodicalIF":1.7000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Facts Views and Vision in ObGyn","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52054/FVVO.16.4.048","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Electrosurgery is widely used in all surgical specialities. There is evidence that surgeons in different disciplines and with different experience levels have an inadequate understanding of the basics of electrosurgery and its complications. This can increase the risk of electrosurgical complications. Despite its improved safety technology, electrosurgery is still associated with serious morbidity and mortality. In addition, such adverse outcomes will incur financial losses to our health system due to the costs of repeated operations, prolonged hospital stays, and litigation.

Objectives: To identify the various mechanisms of electrosurgical complications and to highlight the recommended actions to prevent such complications.

Materials and methods: Narrative review based on a literature search of the Medline database using the following search terms: "electrosurgery", "complications", "risks", and "adverse effects", with further citation searching for related articles.

Main outcome measures and results: The paper does not address specific research questions but addresses common knowledge gaps in the mechanisms of electrosurgical complications among surgeons.

Conclusions: Electrosurgical devices can cause severe complications such as unintended tissue burns, surgical fires, smoke hazards, and interference with implantable devices. Although such energy devices are designed with increasingly improving safety features, an adequate understanding of the circumstances, mechanisms, and prevention of these complications by the surgical team is the cornerstone in mitigating such risks.

电外科并发症:机制和预防策略。
背景:电外科广泛应用于所有外科专业。有证据表明,不同学科和不同经验水平的外科医生对电外科手术及其并发症的基础知识理解不足。这可能会增加电手术并发症的风险。尽管安全技术得到了改进,但电外科手术仍然与严重的发病率和死亡率有关。此外,由于重复手术、延长住院时间和诉讼的费用,这些不良后果将给我们的卫生系统带来经济损失。目的:明确电外科并发症的各种机制,并强调预防此类并发症的推荐措施。材料和方法:基于Medline数据库的文献检索,使用以下检索词:“电外科手术”、“并发症”、“风险”和“不良反应”,并进一步检索相关文章的引文。主要结果测量和结果:本文没有解决具体的研究问题,但解决了外科医生在电外科并发症机制方面的共同知识差距。结论:电手术装置可引起严重的并发症,如意外组织烧伤、手术火灾、烟雾危害和对植入式装置的干扰。虽然这种能量装置的设计具有越来越高的安全性,但外科团队对这些并发症的情况、机制和预防的充分了解是减轻此类风险的基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Facts Views and Vision in ObGyn
Facts Views and Vision in ObGyn OBSTETRICS & GYNECOLOGY-
自引率
15.00%
发文量
59
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信