A field-friendly alternative to freeze-drying faeces for glucocorticoid metabolite quantification in animals of different feeding classes.

IF 1.6 Q2 MULTIDISCIPLINARY SCIENCES
MethodsX Pub Date : 2024-11-30 eCollection Date: 2024-12-01 DOI:10.1016/j.mex.2024.103077
Kayla Rae Osburn, Bruce Crossey, Tshepiso L Majelantle, Andre Ganswindt
{"title":"A field-friendly alternative to freeze-drying faeces for glucocorticoid metabolite quantification in animals of different feeding classes.","authors":"Kayla Rae Osburn, Bruce Crossey, Tshepiso L Majelantle, Andre Ganswindt","doi":"10.1016/j.mex.2024.103077","DOIUrl":null,"url":null,"abstract":"<p><p>Monitoring stress-related faecal glucocorticoid metabolite (fGCM) concentrations is a reliable, popular and established approach for understanding wildlife responses to perceived stressors. To maintain fGCM integrity post-defaecation, faecal material must be promptly stored frozen, or dried to prevent continued suspected bacterial enzyme activity. We compare the effectiveness of freeze-drying with other field-friendly drying techniques (food dehydrator and homemade solar oven). We collected 10 fresh faecal samples each from nine species (giraffe, impala, blue wildebeest, plains zebra, African elephant, white rhino, cheetah, spotted hyena, and leopard) and monitored alterations in fGCM concentrations over time utilizing these different drying techniques. Our findings indicate that a homemade solar oven is as effective as freeze-drying faecal samples. A food dehydrator is also a suitable method for drying faecal samples for the carnivores monitored. Our findings provide field-friendly methods for researchers dealing with logistical constraints in remote field sites.•For all species examined, a homemade solar oven offers a practical and affordable alternative to freeze-drying faeces for fGCM quantification.•A food dehydrator provides an affordable alternative to freeze-drying faeces for fGCM analysis when monitoring carnivores.•Different faecal sample drying techniques should not be utilized within a single study to ensure comparable analyses of fGCM values.</p>","PeriodicalId":18446,"journal":{"name":"MethodsX","volume":"13 ","pages":"103077"},"PeriodicalIF":1.6000,"publicationDate":"2024-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11665413/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"MethodsX","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.mex.2024.103077","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Monitoring stress-related faecal glucocorticoid metabolite (fGCM) concentrations is a reliable, popular and established approach for understanding wildlife responses to perceived stressors. To maintain fGCM integrity post-defaecation, faecal material must be promptly stored frozen, or dried to prevent continued suspected bacterial enzyme activity. We compare the effectiveness of freeze-drying with other field-friendly drying techniques (food dehydrator and homemade solar oven). We collected 10 fresh faecal samples each from nine species (giraffe, impala, blue wildebeest, plains zebra, African elephant, white rhino, cheetah, spotted hyena, and leopard) and monitored alterations in fGCM concentrations over time utilizing these different drying techniques. Our findings indicate that a homemade solar oven is as effective as freeze-drying faecal samples. A food dehydrator is also a suitable method for drying faecal samples for the carnivores monitored. Our findings provide field-friendly methods for researchers dealing with logistical constraints in remote field sites.•For all species examined, a homemade solar oven offers a practical and affordable alternative to freeze-drying faeces for fGCM quantification.•A food dehydrator provides an affordable alternative to freeze-drying faeces for fGCM analysis when monitoring carnivores.•Different faecal sample drying techniques should not be utilized within a single study to ensure comparable analyses of fGCM values.

在不同饲养类别的动物中进行糖皮质激素代谢物定量分析,以替代冷冻干燥粪便。
监测应激相关的粪便糖皮质激素代谢物(fGCM)浓度是了解野生动物对感知应激源反应的可靠、流行和成熟的方法。为了在排便后保持fGCM的完整性,粪便必须立即冷冻或干燥保存,以防止可疑细菌酶活性继续存在。我们比较了冷冻干燥的有效性与其他现场友好的干燥技术(食品脱水机和自制太阳能烤箱)。我们收集了9个物种(长颈鹿、黑斑羚、蓝角马、平原斑马、非洲象、白犀牛、猎豹、斑点鬣狗和豹子)的10份新鲜粪便样本,并利用这些不同的干燥技术监测fGCM浓度随时间的变化。我们的研究结果表明,自制太阳能烤箱与冷冻干燥粪便样品一样有效。食物脱水机也是用于干燥所监测的食肉动物粪便样品的合适方法。我们的研究结果为研究人员处理偏远现场的后勤限制提供了实地友好的方法。•对于所有被检测的物种,自制太阳能烤箱为fGCM定量提供了一种实用且经济实惠的替代方法,可用于冷冻干燥粪便。•在监测食肉动物时,食品脱水机为fGCM分析提供了一种经济实惠的替代方法,可用于冷冻干燥粪便。•不应在单一研究中使用不同的粪便样本干燥技术,以确保fGCM值的可比分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
MethodsX
MethodsX Health Professions-Medical Laboratory Technology
CiteScore
3.60
自引率
5.30%
发文量
314
审稿时长
7 weeks
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信