{"title":"Utilization of 3D-Printed Customized Uncemented Stem Prostheses for Revision of Aseptic Loosening in the Distal Femoral Cemented Prostheses: Case Series and Literature Review.","authors":"Zi-Wei Hou, Kai Zheng, Ming Xu, Xiu-Chun Yu","doi":"10.1111/os.14331","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Aseptic loosening (AL) is a common mechanical complication following reconstruction of the distal femoral cemented prosthesis (DFCP), often resulting in severe bone loss, which complicates prosthesis revision. 3D-printed personalized implants represent an emerging solution for the reconstruction of complex bone defects. This study aimed to investigate the early therapeutic effects of using a 3D-printed, customized, uncemented stem prosthesis for revising aseptic AL in DFCP.</p><p><strong>Methods: </strong>From June 2021 to December 2022, a retrospective review was conducted on six consecutive patients who underwent revision surgery due to AL of the DFCP with a 3D-printed customized uncemented stem prosthesis. The study included four male and two female patients, with an average age of 58 ± 11 (range: 46-75) years. All six patients had previously undergone limb salvage surgery using a cemented megaprosthesis after tumor resection. Preoperative imaging evaluation was performed for all patients, and the personalized design of the prostheses was achieved through 3D printing based on CT imaging data. Regular clinical and radiographic follow-up was conducted postoperatively, with the main outcome measures being oncological outcomes, prosthesis survival, osseointegration, complications, and lower limb function.</p><p><strong>Results: </strong>All patients successfully underwent surgery and were followed up for a mean duration of 30.33 ± 6.15 (range: 24-38) months. All patients were alive at the last follow-up, with no tumor recurrence or distant metastasis. No complications such as infection, loosening, or fracture of the prosthesis occurred. Osseointegration was satisfactory, with a mean MSTS score of 26 (range: 20-28) points.</p><p><strong>Conclusion: </strong>3D-printed, customized, uncemented stem prosthesis exhibit immediate initial stability and reliable biocompatibility. Early clinical outcomes are satisfactory, making them an effective method for revision AL of DFCP.</p>","PeriodicalId":19566,"journal":{"name":"Orthopaedic Surgery","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthopaedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/os.14331","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Aseptic loosening (AL) is a common mechanical complication following reconstruction of the distal femoral cemented prosthesis (DFCP), often resulting in severe bone loss, which complicates prosthesis revision. 3D-printed personalized implants represent an emerging solution for the reconstruction of complex bone defects. This study aimed to investigate the early therapeutic effects of using a 3D-printed, customized, uncemented stem prosthesis for revising aseptic AL in DFCP.

Methods: From June 2021 to December 2022, a retrospective review was conducted on six consecutive patients who underwent revision surgery due to AL of the DFCP with a 3D-printed customized uncemented stem prosthesis. The study included four male and two female patients, with an average age of 58 ± 11 (range: 46-75) years. All six patients had previously undergone limb salvage surgery using a cemented megaprosthesis after tumor resection. Preoperative imaging evaluation was performed for all patients, and the personalized design of the prostheses was achieved through 3D printing based on CT imaging data. Regular clinical and radiographic follow-up was conducted postoperatively, with the main outcome measures being oncological outcomes, prosthesis survival, osseointegration, complications, and lower limb function.

Results: All patients successfully underwent surgery and were followed up for a mean duration of 30.33 ± 6.15 (range: 24-38) months. All patients were alive at the last follow-up, with no tumor recurrence or distant metastasis. No complications such as infection, loosening, or fracture of the prosthesis occurred. Osseointegration was satisfactory, with a mean MSTS score of 26 (range: 20-28) points.

Conclusion: 3D-printed, customized, uncemented stem prosthesis exhibit immediate initial stability and reliable biocompatibility. Early clinical outcomes are satisfactory, making them an effective method for revision AL of DFCP.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Orthopaedic Surgery
Orthopaedic Surgery ORTHOPEDICS-
CiteScore
3.40
自引率
14.30%
发文量
374
审稿时长
20 weeks
期刊介绍: Orthopaedic Surgery (OS) is the official journal of the Chinese Orthopaedic Association, focusing on all aspects of orthopaedic technique and surgery. The journal publishes peer-reviewed articles in the following categories: Original Articles, Clinical Articles, Review Articles, Guidelines, Editorials, Commentaries, Surgical Techniques, Case Reports and Meeting Reports.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信