Estimation of effective dose and ridk of exposure-induced cancer death,and diagnostic reference level for CT scans in Tabriz, Iran.

IF 1.7 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Hamed Zamani, Maedeh Yektamanesh, Fatemeh Shiridokht, Soheila Sharifian Jazi, Reza Javadrashid, Amir Ghasemi Jangjoo, Mikaeil Molazadeh, Alireza Farajollahi, Tohid Mortezazadeh
{"title":"Estimation of effective dose and ridk of exposure-induced cancer death,and diagnostic reference level for CT scans in Tabriz, Iran.","authors":"Hamed Zamani, Maedeh Yektamanesh, Fatemeh Shiridokht, Soheila Sharifian Jazi, Reza Javadrashid, Amir Ghasemi Jangjoo, Mikaeil Molazadeh, Alireza Farajollahi, Tohid Mortezazadeh","doi":"10.1007/s12194-024-00872-0","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to estimate the effective dose and the risk of exposure-induced cancer death (REID), as well as to establish diagnostic reference levels (DRLs) for common CT examinations conducted in Tabriz, Iran. The investigation included adult patients undergoing abdomen-pelvis, brain, neck, sinus, and chest CT scans. Patient data, exposure parameters, and radiation dose metrics, such as volume CT dose index (CTDI<sub>vol</sub>) and dose length product (DLP), were collected and analyzed. The results showed significant variations in radiation dose across different centers for the CT scans. The average effective doses for the different CT scans were 5.65, 1.08, 1.40, 0.46, and 3.68 mSv for abdomen-pelvis, brain, neck, sinus, and chest scans, respectively. The REID values ranged from 14 per million (for sinus scans) to 196 per million (for abdomen-pelvis scans). Additionally, the DRL values for CTDIvol were 11.03 (for abdomen-pelvis), 59.52 (for brain), 8.33 (for neck), 17.05 (for sinus), and 7.83 mGy (for chest). Our results showed that most of the investigated CT scans had lower effective doses compared to the literature and the REIDs were estimated to be low. Minimizing radiation risk can be achieved by reducing CT exams and keeping doses as low as reasonably achievable. The local DRLs from this study were comparable to previous reports and can serve as benchmarks for setting national and international DRLs, helping healthcare facilities optimize radiation practices and improve patient safety in diagnostic imaging.</p>","PeriodicalId":46252,"journal":{"name":"Radiological Physics and Technology","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2024-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiological Physics and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12194-024-00872-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

This study aimed to estimate the effective dose and the risk of exposure-induced cancer death (REID), as well as to establish diagnostic reference levels (DRLs) for common CT examinations conducted in Tabriz, Iran. The investigation included adult patients undergoing abdomen-pelvis, brain, neck, sinus, and chest CT scans. Patient data, exposure parameters, and radiation dose metrics, such as volume CT dose index (CTDIvol) and dose length product (DLP), were collected and analyzed. The results showed significant variations in radiation dose across different centers for the CT scans. The average effective doses for the different CT scans were 5.65, 1.08, 1.40, 0.46, and 3.68 mSv for abdomen-pelvis, brain, neck, sinus, and chest scans, respectively. The REID values ranged from 14 per million (for sinus scans) to 196 per million (for abdomen-pelvis scans). Additionally, the DRL values for CTDIvol were 11.03 (for abdomen-pelvis), 59.52 (for brain), 8.33 (for neck), 17.05 (for sinus), and 7.83 mGy (for chest). Our results showed that most of the investigated CT scans had lower effective doses compared to the literature and the REIDs were estimated to be low. Minimizing radiation risk can be achieved by reducing CT exams and keeping doses as low as reasonably achievable. The local DRLs from this study were comparable to previous reports and can serve as benchmarks for setting national and international DRLs, helping healthcare facilities optimize radiation practices and improve patient safety in diagnostic imaging.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Radiological Physics and Technology
Radiological Physics and Technology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
3.00
自引率
12.50%
发文量
40
期刊介绍: The purpose of the journal Radiological Physics and Technology is to provide a forum for sharing new knowledge related to research and development in radiological science and technology, including medical physics and radiological technology in diagnostic radiology, nuclear medicine, and radiation therapy among many other radiological disciplines, as well as to contribute to progress and improvement in medical practice and patient health care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信