Hexagonal Morphology Nickel Sulfide Anchored on Graphene Oxide–Modified Glassy Carbon Electrode for the Sensitive Detection of Paracetamol in Biological Samples

IF 2.7 4区 化学 Q3 CHEMISTRY, PHYSICAL
A. Dhamodharan, E. Murugan, Huaxiang Li, Xiangfeng Zheng, Yajun Gao, Tianzhu Guan, Shengqi Rao, Huan Pang, K. Perumal
{"title":"Hexagonal Morphology Nickel Sulfide Anchored on Graphene Oxide–Modified Glassy Carbon Electrode for the Sensitive Detection of Paracetamol in Biological Samples","authors":"A. Dhamodharan,&nbsp;E. Murugan,&nbsp;Huaxiang Li,&nbsp;Xiangfeng Zheng,&nbsp;Yajun Gao,&nbsp;Tianzhu Guan,&nbsp;Shengqi Rao,&nbsp;Huan Pang,&nbsp;K. Perumal","doi":"10.1007/s12678-024-00909-3","DOIUrl":null,"url":null,"abstract":"<div><p>Healthcare diagnostics and supplementary experimental research require electrochemical tools that are straightforward, inexpensive, delicate, quick, and precise. In addition to the previous reports of paracetamol sensors, we present an electrochemical sensor that customs differential pulse voltammetry (DPV) and cyclic voltammetry (CV) to determine the presence of nickel sulfide (NiS) on graphene oxide sheets (GO) (NiS@GO). Utilizing analytical methods, the composite surface morphology and structural characteristics were described. A substantial drop in overpotential was seen in the electrochemical investigation of the NiS@GO composite revised glassy carbon electrode (NiS@GO/GCE) owing to its substantial external part and high hauler agility, which demonstrated remarkable activity towards the oxidation of paracetamol (Para). Para electrochemical sensing was made more accessible by a diffusion-controlled oxidation process with an identical quantity of protons and electrons. From 3.3 µM to 125 µM the concentration of Para ornament linearly with the peak currents during the determination process 0.052 µM was the Para detection limit (3σ/S) sensitivity of the fabricated electrode was 12.14 µA µM<sup>−1</sup>. In addition, the sensors demonstrated remarkable recovery with actual tablet samples over a month-long period with very little interference from common species. Commercial tablet samples demonstrate a noteworthy potential for wide-ranging applications in the electrochemical sector, with an acceptable recovery rate of 96.6 to 100.8%. An upfront, affordable quality monitoring system that can track the amount of para in tablets may be developed with the help of the suggested electrochemical sensor. Application investigations using the proposed sensor successfully detected Para in drug tabulations and biological materials.</p><h3>Graphical Abstract</h3>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":535,"journal":{"name":"Electrocatalysis","volume":"16 1","pages":"182 - 195"},"PeriodicalIF":2.7000,"publicationDate":"2024-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrocatalysis","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s12678-024-00909-3","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Healthcare diagnostics and supplementary experimental research require electrochemical tools that are straightforward, inexpensive, delicate, quick, and precise. In addition to the previous reports of paracetamol sensors, we present an electrochemical sensor that customs differential pulse voltammetry (DPV) and cyclic voltammetry (CV) to determine the presence of nickel sulfide (NiS) on graphene oxide sheets (GO) (NiS@GO). Utilizing analytical methods, the composite surface morphology and structural characteristics were described. A substantial drop in overpotential was seen in the electrochemical investigation of the NiS@GO composite revised glassy carbon electrode (NiS@GO/GCE) owing to its substantial external part and high hauler agility, which demonstrated remarkable activity towards the oxidation of paracetamol (Para). Para electrochemical sensing was made more accessible by a diffusion-controlled oxidation process with an identical quantity of protons and electrons. From 3.3 µM to 125 µM the concentration of Para ornament linearly with the peak currents during the determination process 0.052 µM was the Para detection limit (3σ/S) sensitivity of the fabricated electrode was 12.14 µA µM−1. In addition, the sensors demonstrated remarkable recovery with actual tablet samples over a month-long period with very little interference from common species. Commercial tablet samples demonstrate a noteworthy potential for wide-ranging applications in the electrochemical sector, with an acceptable recovery rate of 96.6 to 100.8%. An upfront, affordable quality monitoring system that can track the amount of para in tablets may be developed with the help of the suggested electrochemical sensor. Application investigations using the proposed sensor successfully detected Para in drug tabulations and biological materials.

Graphical Abstract

求助全文
约1分钟内获得全文 求助全文
来源期刊
Electrocatalysis
Electrocatalysis CHEMISTRY, PHYSICAL-ELECTROCHEMISTRY
CiteScore
4.80
自引率
6.50%
发文量
93
审稿时长
>12 weeks
期刊介绍: Electrocatalysis is cross-disciplinary in nature, and attracts the interest of chemists, physicists, biochemists, surface and materials scientists, and engineers. Electrocatalysis provides the unique international forum solely dedicated to the exchange of novel ideas in electrocatalysis for academic, government, and industrial researchers. Quick publication of new results, concepts, and inventions made involving Electrocatalysis stimulates scientific discoveries and breakthroughs, promotes the scientific and engineering concepts that are critical to the development of novel electrochemical technologies. Electrocatalysis publishes original submissions in the form of letters, research papers, review articles, book reviews, and educational papers. Letters are preliminary reports that communicate new and important findings. Regular research papers are complete reports of new results, and their analysis and discussion. Review articles critically and constructively examine development in areas of electrocatalysis that are of broad interest and importance. Educational papers discuss important concepts whose understanding is vital to advances in theoretical and experimental aspects of electrochemical reactions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信