ChromosomeNet: Deep Learning-Based Automated Chromosome Detection in Metaphase Cell Images

IF 2.7 Q3 ENGINEERING, BIOMEDICAL
Chih-En Kuo;Jun-Zhou Li;Jenn-Jhy Tseng;Feng-Chu Lo;Ming-Jer Chen;Chien-Hsing Lu
{"title":"ChromosomeNet: Deep Learning-Based Automated Chromosome Detection in Metaphase Cell Images","authors":"Chih-En Kuo;Jun-Zhou Li;Jenn-Jhy Tseng;Feng-Chu Lo;Ming-Jer Chen;Chien-Hsing Lu","doi":"10.1109/OJEMB.2024.3512932","DOIUrl":null,"url":null,"abstract":"<italic>Goal:</i>\n Chromosomes are intracellular aggregates that carry genetic information. An abnormal number or structure of chromosomes causes chromosomal disorders. Thus, chromosome screening is crucial for prenatal care; however, manual analysis of chromosomes is time consuming. With the increasing popularity of prenatal diagnosis, human labor resources are overstretched. Therefore, an automatic approach for chromosome detection and recognition is necessary. \n<italic>Methods:</i>\n In the present study, we proposed a deep learning–based system for the automatic chromosome detection and recognition of metaphase cell images. We used a large database that included 5,000 metaphase cell images consisting of a total of 229,852 chromosomes. The proposed system was then developed and evaluated. The system, called ChromosomesNet, which combines the advantages of one-stage and two-stage models. The model uses original images as inputs without requiring preprocessing; it is thus applicable for clinical settings. To verify the clinical applicability of our system, we included 3,827 simple images and 1,173 difficult images, as identified by physicians, in our database. \n<italic>Results:</i>\n We used COCOAPI's mAP50 evaluation method, which has average performance and a high accuracy of 99.60%. Moreover, the recall and F1 score of our proposed method were 99.9% and 99.49%, respectively. We also compared our method with five well-known object detection methods, including Faster-RCNN, YOLOv7, Retinanet, Swin transformer, and Centernet++. The results indicated that ChromosomesNet had the highest accuracy, recall, and F1 score. Unlike previous studies that have reported simple chromosome images as identification results, we obtained a 99.5% accuracy in the detection of difficult images. \n<italic>Conclusions:</i>\n The volume of data we tested, even including difficult images, was much larger than those in the literature. The results indicated that our proposed method is sufficiently stable, robustness, and practical for clinical use. Future studies are warranted to confirm the clinical applicability of our proposed method by using data from other hospitals for cross-hospital validation.","PeriodicalId":33825,"journal":{"name":"IEEE Open Journal of Engineering in Medicine and Biology","volume":"6 ","pages":"227-236"},"PeriodicalIF":2.7000,"publicationDate":"2024-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10786357","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Open Journal of Engineering in Medicine and Biology","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10786357/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Goal: Chromosomes are intracellular aggregates that carry genetic information. An abnormal number or structure of chromosomes causes chromosomal disorders. Thus, chromosome screening is crucial for prenatal care; however, manual analysis of chromosomes is time consuming. With the increasing popularity of prenatal diagnosis, human labor resources are overstretched. Therefore, an automatic approach for chromosome detection and recognition is necessary. Methods: In the present study, we proposed a deep learning–based system for the automatic chromosome detection and recognition of metaphase cell images. We used a large database that included 5,000 metaphase cell images consisting of a total of 229,852 chromosomes. The proposed system was then developed and evaluated. The system, called ChromosomesNet, which combines the advantages of one-stage and two-stage models. The model uses original images as inputs without requiring preprocessing; it is thus applicable for clinical settings. To verify the clinical applicability of our system, we included 3,827 simple images and 1,173 difficult images, as identified by physicians, in our database. Results: We used COCOAPI's mAP50 evaluation method, which has average performance and a high accuracy of 99.60%. Moreover, the recall and F1 score of our proposed method were 99.9% and 99.49%, respectively. We also compared our method with five well-known object detection methods, including Faster-RCNN, YOLOv7, Retinanet, Swin transformer, and Centernet++. The results indicated that ChromosomesNet had the highest accuracy, recall, and F1 score. Unlike previous studies that have reported simple chromosome images as identification results, we obtained a 99.5% accuracy in the detection of difficult images. Conclusions: The volume of data we tested, even including difficult images, was much larger than those in the literature. The results indicated that our proposed method is sufficiently stable, robustness, and practical for clinical use. Future studies are warranted to confirm the clinical applicability of our proposed method by using data from other hospitals for cross-hospital validation.
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
9.50
自引率
3.40%
发文量
20
审稿时长
10 weeks
期刊介绍: The IEEE Open Journal of Engineering in Medicine and Biology (IEEE OJEMB) is dedicated to serving the community of innovators in medicine, technology, and the sciences, with the core goal of advancing the highest-quality interdisciplinary research between these disciplines. The journal firmly believes that the future of medicine depends on close collaboration between biology and technology, and that fostering interaction between these fields is an important way to advance key discoveries that can improve clinical care.IEEE OJEMB is a gold open access journal in which the authors retain the copyright to their papers and readers have free access to the full text and PDFs on the IEEE Xplore® Digital Library. However, authors are required to pay an article processing fee at the time their paper is accepted for publication, using to cover the cost of publication.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信