Laura Sánchez-Bermejo, Pedro Jesús Milla-Ortega, José Manuel Pérez-Mármol
{"title":"Reliability and Optimal Cut-Off Points of the Test for Upper Limb Apraxia (TULIA) for Spanish-Speaking Post-Stroke Patients.","authors":"Laura Sánchez-Bermejo, Pedro Jesús Milla-Ortega, José Manuel Pérez-Mármol","doi":"10.1177/02692155241305250","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the reliability, identify the optimal cut-off points, and determine the diagnostic accuracy of the TULIA Apraxia test in a sample of Spanish-speaking post-stroke patients.</p><p><strong>Design: </strong>Cross-sectional.</p><p><strong>Setting: </strong>Public primary care.</p><p><strong>Participants: </strong>201 post-stroke patients.</p><p><strong>Main measures: </strong>Reliability was assessed using Cronbach's alpha. Cut-off points were identified for each TULIA Apraxia sub-test and stratified for age (≤65 years, > 65 years) using ROC curve analysis, area under the curve, and Youden index. Diagnostic accuracy was evaluated using sensitivity, specificity, and predictive values.</p><p><strong>Results: </strong>Cronbach's alpha of the sub-tests varied from 0.716 (95% CI 0.653-0.772) for pantomime intransitive to 0.824 (95% CI 0.784-0.858) for imitation non-symbolic. Cut-off points ranged from ≤25 to ≤35 points. For individuals aged ≤65 years, the cut-offs that best balanced sensitivity and specificity were ≤25 points for detecting alterations in imitation transitive and ≤33 points for pantomime non-symbolic. For individuals over 65 years, the imitation transitive cut-off (≤26 points) presented the most adjusted balance. The minimum positive predictive value was 0.667 (95% CI 0.542-0.777), indicating that the TULIA Apraxia tests correctly classified more than 67% of patients with apraxia. The minimum negative predictive value was 0.763 (95% CI 0.644-0.859), showing that the test accurately identified more than 76% of patients without apraxia.</p><p><strong>Conclusions: </strong>The TULIA Apraxia test is reliable in Spanish-speaking post-stroke patients. Optimal cut-off points, along with their respective sensitivity and specificity values, exhibit adequate test accuracy. Predictive values indicate that the test correctly identifies individuals with and without apraxia.</p>","PeriodicalId":10441,"journal":{"name":"Clinical Rehabilitation","volume":" ","pages":"2692155241305250"},"PeriodicalIF":2.6000,"publicationDate":"2024-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Rehabilitation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/02692155241305250","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To evaluate the reliability, identify the optimal cut-off points, and determine the diagnostic accuracy of the TULIA Apraxia test in a sample of Spanish-speaking post-stroke patients.
Design: Cross-sectional.
Setting: Public primary care.
Participants: 201 post-stroke patients.
Main measures: Reliability was assessed using Cronbach's alpha. Cut-off points were identified for each TULIA Apraxia sub-test and stratified for age (≤65 years, > 65 years) using ROC curve analysis, area under the curve, and Youden index. Diagnostic accuracy was evaluated using sensitivity, specificity, and predictive values.
Results: Cronbach's alpha of the sub-tests varied from 0.716 (95% CI 0.653-0.772) for pantomime intransitive to 0.824 (95% CI 0.784-0.858) for imitation non-symbolic. Cut-off points ranged from ≤25 to ≤35 points. For individuals aged ≤65 years, the cut-offs that best balanced sensitivity and specificity were ≤25 points for detecting alterations in imitation transitive and ≤33 points for pantomime non-symbolic. For individuals over 65 years, the imitation transitive cut-off (≤26 points) presented the most adjusted balance. The minimum positive predictive value was 0.667 (95% CI 0.542-0.777), indicating that the TULIA Apraxia tests correctly classified more than 67% of patients with apraxia. The minimum negative predictive value was 0.763 (95% CI 0.644-0.859), showing that the test accurately identified more than 76% of patients without apraxia.
Conclusions: The TULIA Apraxia test is reliable in Spanish-speaking post-stroke patients. Optimal cut-off points, along with their respective sensitivity and specificity values, exhibit adequate test accuracy. Predictive values indicate that the test correctly identifies individuals with and without apraxia.
期刊介绍:
Clinical Rehabilitation covering the whole field of disability and rehabilitation, this peer-reviewed journal publishes research and discussion articles and acts as a forum for the international dissemination and exchange of information amongst the large number of professionals involved in rehabilitation. This journal is a member of the Committee on Publication Ethics (COPE)