First preclinical SPECT/CT imaging and biodistribution of [165Er]ErCl3 and [165Er]Er-PSMA-617

IF 4.4 Q1 CHEMISTRY, INORGANIC & NUCLEAR
Behrad Saeedi Saghez, Cristina Rodríguez-Rodríguez, Pedro Luis Esquinas, Helen Merkens, François Bénard, Valery Radchenko, Hua Yang
{"title":"First preclinical SPECT/CT imaging and biodistribution of [165Er]ErCl3 and [165Er]Er-PSMA-617","authors":"Behrad Saeedi Saghez,&nbsp;Cristina Rodríguez-Rodríguez,&nbsp;Pedro Luis Esquinas,&nbsp;Helen Merkens,&nbsp;François Bénard,&nbsp;Valery Radchenko,&nbsp;Hua Yang","doi":"10.1186/s41181-024-00312-9","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p><sup>165</sup>Er (t<sub>1/2</sub> = 10.4 h, E<sub>x-ray</sub> = 47.1 keV (59.4%) and 54.3 keV (14.3%)) is a promising radionuclide suitable for targeted Auger electron therapy of cancer. <sup>165</sup>Er can be produced at a relatively low cost, high yield, and high purity using small medical cyclotrons. As a late lanthanide, <sup>165</sup>Er is easy to label and can be used as a surrogate for other lanthanides or Ac in proof-of-concept studies. In this report, we explore the radiochemistry, in vitro, and in vivo behavior of [<sup>165</sup>Er]ErCl<sub>3</sub> and [<sup>165</sup>Er]Er-PSMA-617 to showcase the application of this radionuclide. Particularly, we report the first phantom and preclinical SPECT imaging of this radionuclide leveraging its characteristic X-ray photon emissions.</p><h3>Results</h3><p>The <sup>165</sup>Ho(p,n)<sup>165</sup>Er nuclear reaction using a 13 MeV cyclotron demonstrated production yields of up to 25 ± 5 MBq. µA<sup>−1</sup> h<sup>−1</sup> at the end of the bombardment. After the purification (4.0 ± 0.5 h) using a sequential combination of cation exchange and extraction chromatography, 4-h irradiation produced up to 1.5 GBq of [<sup>165</sup>Er]ErCl<sub>3</sub>. High molar activity [<sup>165</sup>Er]Er-PSMA-617 was prepared (~ 200 MBq/nmol). [<sup>165</sup>Er]Er-PSMA-617 showed a Log<i>D</i><sub>7.4</sub> value of -2.34 ± 0.24 meaning high hydrophilicity of the complex as expected. The stability of [<sup>165</sup>Er]Er-PSMA-617 in saline, human, and mouse serum was studied and showed intact tracer after 12 h in all three cases. [<sup>165</sup>Er]ErCl<sub>3</sub> and [<sup>165</sup>Er]Er-PSMA-617 were both taken up by LNCaP cells. PSMA-617 has IC<sub>50</sub> at nanomolar range for [<sup>165</sup>Er]Er-PSMA-617 in LNCaP cells. SPECT images with preclinical phantoms showed good uniformity, spatial resolution, and quantitative accuracy. SPECT/CT imaging in LNCaP tumor-bearing mice injected with [<sup>165</sup>Er]Er-PSMA-617 showed high tumor uptake and quantitative accuracy when comparing the results to ex vivo biodistribution %IA/g values. Mice injected with [<sup>165</sup>Er]ErCl<sub>3</sub> showed uptake in bone structures and excretion through both liver and kidneys.</p><h3>Conclusions</h3><p>This study demonstrated the preclinical use of <sup>165</sup>Er for the first time. Using [<sup>165</sup>Er]ErCl<sub>3</sub> and [<sup>165</sup>Er]Er-PSMA-617 as examples, the radiochemistry, cell, and animal studies showed that <sup>165</sup>Er can be used as a tool for evaluating targeted radiopharmaceuticals. The X-ray emission from <sup>165</sup>Er can be used for quantitative SPECT imaging in mice.</p></div>","PeriodicalId":534,"journal":{"name":"EJNMMI Radiopharmacy and Chemistry","volume":"9 1","pages":""},"PeriodicalIF":4.4000,"publicationDate":"2024-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ejnmmipharmchem.springeropen.com/counter/pdf/10.1186/s41181-024-00312-9","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Radiopharmacy and Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1186/s41181-024-00312-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
引用次数: 0

Abstract

Background

165Er (t1/2 = 10.4 h, Ex-ray = 47.1 keV (59.4%) and 54.3 keV (14.3%)) is a promising radionuclide suitable for targeted Auger electron therapy of cancer. 165Er can be produced at a relatively low cost, high yield, and high purity using small medical cyclotrons. As a late lanthanide, 165Er is easy to label and can be used as a surrogate for other lanthanides or Ac in proof-of-concept studies. In this report, we explore the radiochemistry, in vitro, and in vivo behavior of [165Er]ErCl3 and [165Er]Er-PSMA-617 to showcase the application of this radionuclide. Particularly, we report the first phantom and preclinical SPECT imaging of this radionuclide leveraging its characteristic X-ray photon emissions.

Results

The 165Ho(p,n)165Er nuclear reaction using a 13 MeV cyclotron demonstrated production yields of up to 25 ± 5 MBq. µA−1 h−1 at the end of the bombardment. After the purification (4.0 ± 0.5 h) using a sequential combination of cation exchange and extraction chromatography, 4-h irradiation produced up to 1.5 GBq of [165Er]ErCl3. High molar activity [165Er]Er-PSMA-617 was prepared (~ 200 MBq/nmol). [165Er]Er-PSMA-617 showed a LogD7.4 value of -2.34 ± 0.24 meaning high hydrophilicity of the complex as expected. The stability of [165Er]Er-PSMA-617 in saline, human, and mouse serum was studied and showed intact tracer after 12 h in all three cases. [165Er]ErCl3 and [165Er]Er-PSMA-617 were both taken up by LNCaP cells. PSMA-617 has IC50 at nanomolar range for [165Er]Er-PSMA-617 in LNCaP cells. SPECT images with preclinical phantoms showed good uniformity, spatial resolution, and quantitative accuracy. SPECT/CT imaging in LNCaP tumor-bearing mice injected with [165Er]Er-PSMA-617 showed high tumor uptake and quantitative accuracy when comparing the results to ex vivo biodistribution %IA/g values. Mice injected with [165Er]ErCl3 showed uptake in bone structures and excretion through both liver and kidneys.

Conclusions

This study demonstrated the preclinical use of 165Er for the first time. Using [165Er]ErCl3 and [165Er]Er-PSMA-617 as examples, the radiochemistry, cell, and animal studies showed that 165Er can be used as a tool for evaluating targeted radiopharmaceuticals. The X-ray emission from 165Er can be used for quantitative SPECT imaging in mice.

[165Er]ErCl3和[165Er]Er-PSMA-617的首次临床前SPECT/CT成像和生物分布
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.20
自引率
8.70%
发文量
30
审稿时长
5 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信