Single-port robot-assisted thoracoscopic right lower bronchial sleeve lobectomy utilizing the Shurui single-port robotic system.

IF 2.1 3区 医学 Q3 RESPIRATORY SYSTEM
Journal of thoracic disease Pub Date : 2024-11-30 Epub Date: 2024-11-21 DOI:10.21037/jtd-24-957
Chang Li, Xin-Yu Zhu, Diego Gonzalez-Rivas, Jun Zhao
{"title":"Single-port robot-assisted thoracoscopic right lower bronchial sleeve lobectomy utilizing the Shurui single-port robotic system.","authors":"Chang Li, Xin-Yu Zhu, Diego Gonzalez-Rivas, Jun Zhao","doi":"10.21037/jtd-24-957","DOIUrl":null,"url":null,"abstract":"<p><p>Sleeve lobectomy has solidified its position as a preferred alternative to pneumonectomy due to its significant advantage in preserving lung function, whereas right lower lobe sleeve lobectomy remains relatively uncommon because of the higher technical challenge. With the development of minimally invasive technology and experience acquired over the years, robot-assisted thoracoscopic surgery (RATS) has shown progress and distinct advantages compared to the traditional thoracotomy and video-assisted thoracoscopic surgery (VATS) approach. Owing to its 3D vision, bendable wrist joints, and tremor filtration capabilities, this surgical technique exhibits great advantages in complex thoracic operations demanding for reconstructive procedures compared to traditional thoracoscopic surgery. The Davinci Xi system has been employed in a substantial number of sleeve resections via a single-port approach. However, the Davinci Xi system was first designed for multi-port thoracic surgery, which poses challenges for adaptation to single-port surgery. Additionally, the newer Davinci SP system, with its 2.5 cm port diameter, cannot be inserted through an intercostal incision and can only be utilized for lung surgery via a subcostal incision, thus restricting its application in complex lung surgeries such as sleeve resection. Here we present a case report on a right lower sleeve lobectomy utilizing the innovative Shurui single-port robotic system which exhibits several advantages in the realm of lung surgery compared to traditional procedures.</p>","PeriodicalId":17542,"journal":{"name":"Journal of thoracic disease","volume":"16 11","pages":"7920-7925"},"PeriodicalIF":2.1000,"publicationDate":"2024-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11635244/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of thoracic disease","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.21037/jtd-24-957","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/21 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0

Abstract

Sleeve lobectomy has solidified its position as a preferred alternative to pneumonectomy due to its significant advantage in preserving lung function, whereas right lower lobe sleeve lobectomy remains relatively uncommon because of the higher technical challenge. With the development of minimally invasive technology and experience acquired over the years, robot-assisted thoracoscopic surgery (RATS) has shown progress and distinct advantages compared to the traditional thoracotomy and video-assisted thoracoscopic surgery (VATS) approach. Owing to its 3D vision, bendable wrist joints, and tremor filtration capabilities, this surgical technique exhibits great advantages in complex thoracic operations demanding for reconstructive procedures compared to traditional thoracoscopic surgery. The Davinci Xi system has been employed in a substantial number of sleeve resections via a single-port approach. However, the Davinci Xi system was first designed for multi-port thoracic surgery, which poses challenges for adaptation to single-port surgery. Additionally, the newer Davinci SP system, with its 2.5 cm port diameter, cannot be inserted through an intercostal incision and can only be utilized for lung surgery via a subcostal incision, thus restricting its application in complex lung surgeries such as sleeve resection. Here we present a case report on a right lower sleeve lobectomy utilizing the innovative Shurui single-port robotic system which exhibits several advantages in the realm of lung surgery compared to traditional procedures.

袖带肺叶切除术因其在保留肺功能方面的显著优势,已巩固了其作为肺切除术首选替代方案的地位,而右下叶袖带肺叶切除术因其技术难度较高,仍相对少见。随着微创技术的发展和多年来积累的经验,机器人辅助胸腔镜手术(RATS)与传统的开胸手术和视频辅助胸腔镜手术(VATS)相比取得了进步和明显的优势。与传统胸腔镜手术相比,机器人胸腔镜手术凭借其三维视觉、可弯曲的腕关节和震颤过滤功能,在要求重建手术的复杂胸腔手术中表现出巨大优势。Davinci Xi 系统已在大量通过单孔方法进行的袖状切除术中得到应用。然而,Davinci Xi 系统最初是为多孔胸腔镜手术设计的,这给单孔手术的适应性带来了挑战。此外,较新的 Davinci SP 系统的端口直径为 2.5 厘米,无法通过肋间切口插入,只能通过肋下切口进行肺部手术,因此限制了其在袖状切除术等复杂肺部手术中的应用。与传统手术相比,Shurui 单孔机器人系统在肺部手术领域具有多项优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of thoracic disease
Journal of thoracic disease RESPIRATORY SYSTEM-
CiteScore
4.60
自引率
4.00%
发文量
254
期刊介绍: The Journal of Thoracic Disease (JTD, J Thorac Dis, pISSN: 2072-1439; eISSN: 2077-6624) was founded in Dec 2009, and indexed in PubMed in Dec 2011 and Science Citation Index SCI in Feb 2013. It is published quarterly (Dec 2009- Dec 2011), bimonthly (Jan 2012 - Dec 2013), monthly (Jan. 2014-) and openly distributed worldwide. JTD received its impact factor of 2.365 for the year 2016. JTD publishes manuscripts that describe new findings and provide current, practical information on the diagnosis and treatment of conditions related to thoracic disease. All the submission and reviewing are conducted electronically so that rapid review is assured.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信