{"title":"Towards U-Net-based intraoperative 2D dose prediction in high dose rate prostate brachytherapy","authors":"Eric Knull , Christopher W. Smith , Aaron D. Ward , Aaron Fenster , Douglas A. Hoover","doi":"10.1016/j.brachy.2024.11.007","DOIUrl":null,"url":null,"abstract":"<div><h3>BACKGROUND</h3><div>Poor needle placement in prostate high-dose-rate brachytherapy (HDR-BT) results in sub-optimal dosimetry and mentally predicting these effects during HDR-BT is difficult, creating a barrier to widespread availability of high-quality prostate HDR-BT.</div></div><div><h3>PURPOSE</h3><div>To provide earlier feedback on needle implantation quality, we trained machine learning models to predict 2D dosimetry for prostate HDR-BT on axial TRUS images.</div></div><div><h3>METHODS AND MATERIALS</h3><div>Clinical treatment plans from 248 prostate HDR-BT patients were retrospectively collected and randomly split 80/20 for training/testing. Fifteen U-Net models were implemented to predict the 90%, 100%, 120%, 150%, and 200% isodose levels in the prostate base, midgland, and apex. Predicted isodose lines were compared to delivered dose using Dice similarity coefficient (DSC), precision, recall, average symmetric surface distance, area percent difference, and 95th percentile Hausdorff distance. To benchmark performance, 10 cases were retrospectively replanned and compared against the clinical plans using the same metrics.</div></div><div><h3>RESULTS</h3><div>Models predicting 90% and 100% isodose lines at midgland performed best, with median DSC of 0.97 and 0.96, respectively. Performance declined as isodose level increased, with median DSC of 0.90, 0.79, and 0.65 in the 120%, 150%, and 200% models. In the base, median DSC was 0.94 for 90% and decreased to 0.64 for 200%. In the apex, median DSC was 0.93 for 90% and decreased to 0.63 for 200%. Median prediction time was 25 ms.</div></div><div><h3>CONCLUSION</h3><div>U-Net models accurately predicted HDR-BT isodose lines on 2D TRUS images sufficiently quickly for real-time use. Incorporating auto-segmentation algorithms will allow intra-operative feedback on needle implantation quality.</div></div>","PeriodicalId":55334,"journal":{"name":"Brachytherapy","volume":"24 2","pages":"Pages 328-338"},"PeriodicalIF":1.7000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brachytherapy","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1538472124004574","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
BACKGROUND
Poor needle placement in prostate high-dose-rate brachytherapy (HDR-BT) results in sub-optimal dosimetry and mentally predicting these effects during HDR-BT is difficult, creating a barrier to widespread availability of high-quality prostate HDR-BT.
PURPOSE
To provide earlier feedback on needle implantation quality, we trained machine learning models to predict 2D dosimetry for prostate HDR-BT on axial TRUS images.
METHODS AND MATERIALS
Clinical treatment plans from 248 prostate HDR-BT patients were retrospectively collected and randomly split 80/20 for training/testing. Fifteen U-Net models were implemented to predict the 90%, 100%, 120%, 150%, and 200% isodose levels in the prostate base, midgland, and apex. Predicted isodose lines were compared to delivered dose using Dice similarity coefficient (DSC), precision, recall, average symmetric surface distance, area percent difference, and 95th percentile Hausdorff distance. To benchmark performance, 10 cases were retrospectively replanned and compared against the clinical plans using the same metrics.
RESULTS
Models predicting 90% and 100% isodose lines at midgland performed best, with median DSC of 0.97 and 0.96, respectively. Performance declined as isodose level increased, with median DSC of 0.90, 0.79, and 0.65 in the 120%, 150%, and 200% models. In the base, median DSC was 0.94 for 90% and decreased to 0.64 for 200%. In the apex, median DSC was 0.93 for 90% and decreased to 0.63 for 200%. Median prediction time was 25 ms.
CONCLUSION
U-Net models accurately predicted HDR-BT isodose lines on 2D TRUS images sufficiently quickly for real-time use. Incorporating auto-segmentation algorithms will allow intra-operative feedback on needle implantation quality.
期刊介绍:
Brachytherapy is an international and multidisciplinary journal that publishes original peer-reviewed articles and selected reviews on the techniques and clinical applications of interstitial and intracavitary radiation in the management of cancers. Laboratory and experimental research relevant to clinical practice is also included. Related disciplines include medical physics, medical oncology, and radiation oncology and radiology. Brachytherapy publishes technical advances, original articles, reviews, and point/counterpoint on controversial issues. Original articles that address any aspect of brachytherapy are invited. Letters to the Editor-in-Chief are encouraged.