The different serum albumin assays influence calcium status in haemodialysis patients: a comparative study against free calcium as a reference method.

IF 3.8 2区 医学 Q1 MEDICAL LABORATORY TECHNOLOGY
Osama Eisa, Mohammed Dafaalla, Mark Wright, Muhammad Faisal, Kevin Stuart, Nuthar Jassam
{"title":"The different serum albumin assays influence calcium status in haemodialysis patients: a comparative study against free calcium as a reference method.","authors":"Osama Eisa, Mohammed Dafaalla, Mark Wright, Muhammad Faisal, Kevin Stuart, Nuthar Jassam","doi":"10.1515/cclm-2024-1030","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Accurate assessment of calcium levels is crucial for optimal management of regular Haemodialysis (HD) patients. Different calcium adjustment equations and albumin methods; including bromocresol purple (BCP) and bromocresol green (BCG) assays are employed by laboratories, which cause considerable discrepancies between reported results. The aim of this study is to assess the influence of albumin assays on calcium status in stable haemodialysis patients against free calcium (fCa) as a gold standard test.</p><p><strong>Methods: </strong>103 paired serum and fCa samples were collected from a cohort of stable HD patients. Albumin levels were measured by either the BCP or BCG method, and samples were also analysed for the total calcium (T.Ca), phosphate, bicarbonate, and pH levels. The performance of BCG-based and BCP-based adjusted calcium equations was compared using Z-scores scatter plots, intraclass correlation coefficient and Cohen Kappa statistic, with fCa being the reference standard.</p><p><strong>Results: </strong>Unadjusted T.Ca achieved a 70 % overall classification agreement with fCa and identified 61 % of the \"true\" hypocalcaemic samples. Adjusted calcium concentrations, calculated by either BCP- or BCG-based equation, were poor predictors of fCa; with more than 50 % of the hypocalcaemic samples being misclassified as normocalcaemic. Notably, both equations misclassified the calcium status in 5 (4.9 %) patients with severe hypocalcaemia (i.e., potentially requiring calcium infusion) as mild hypocalcaemia.</p><p><strong>Conclusions: </strong>Our study showed evidence of hidden hypocalcaemia being missed by the current practice of using adjusted calcium in HD patients. Therefore, we recommend abandoning the adjustment procedure in samples from stable HD patients in favour of fCa measurement.</p>","PeriodicalId":10390,"journal":{"name":"Clinical chemistry and laboratory medicine","volume":" ","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2024-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical chemistry and laboratory medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/cclm-2024-1030","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Accurate assessment of calcium levels is crucial for optimal management of regular Haemodialysis (HD) patients. Different calcium adjustment equations and albumin methods; including bromocresol purple (BCP) and bromocresol green (BCG) assays are employed by laboratories, which cause considerable discrepancies between reported results. The aim of this study is to assess the influence of albumin assays on calcium status in stable haemodialysis patients against free calcium (fCa) as a gold standard test.

Methods: 103 paired serum and fCa samples were collected from a cohort of stable HD patients. Albumin levels were measured by either the BCP or BCG method, and samples were also analysed for the total calcium (T.Ca), phosphate, bicarbonate, and pH levels. The performance of BCG-based and BCP-based adjusted calcium equations was compared using Z-scores scatter plots, intraclass correlation coefficient and Cohen Kappa statistic, with fCa being the reference standard.

Results: Unadjusted T.Ca achieved a 70 % overall classification agreement with fCa and identified 61 % of the "true" hypocalcaemic samples. Adjusted calcium concentrations, calculated by either BCP- or BCG-based equation, were poor predictors of fCa; with more than 50 % of the hypocalcaemic samples being misclassified as normocalcaemic. Notably, both equations misclassified the calcium status in 5 (4.9 %) patients with severe hypocalcaemia (i.e., potentially requiring calcium infusion) as mild hypocalcaemia.

Conclusions: Our study showed evidence of hidden hypocalcaemia being missed by the current practice of using adjusted calcium in HD patients. Therefore, we recommend abandoning the adjustment procedure in samples from stable HD patients in favour of fCa measurement.

目的:准确评估血钙水平对常规血液透析(HD)患者的最佳管理至关重要。实验室采用不同的钙调整方程和白蛋白方法,包括溴甲酚紫(BCP)和溴甲酚绿(BCG)测定法,这导致报告结果之间存在很大差异。本研究旨在评估白蛋白测定法对稳定期血液透析患者钙状况的影响,并将游离钙(fCa)作为金标准检测方法。采用 BCP 或 BCG 方法测量白蛋白水平,同时分析样本的总钙(T.Ca)、磷酸盐、碳酸氢盐和 pH 水平。以 fCa 为参考标准,使用 Z 值散点图、类内相关系数和 Cohen Kappa 统计量比较了基于 BCG 和基于 BCP 的调整钙方程的性能:结果:未经调整的 T.Ca 与 fCa 的总体分类一致率为 70%,可识别 61% 的 "真正 "低钙血症样本。根据 BCP 或 BCG 方程计算的调整后钙浓度对 fCa 的预测效果不佳;50% 以上的低钙血症样本被误诊为正常钙血症。值得注意的是,这两种方程都将 5 例(4.9%)严重低钙血症(即可能需要输注钙剂)患者的钙状态误诊为轻度低钙血症:我们的研究表明,目前在 HD 患者中使用调整钙的做法会遗漏隐藏的低钙血症。因此,我们建议放弃在病情稳定的 HD 患者样本中使用调整程序,转而使用 fCa 测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Clinical chemistry and laboratory medicine
Clinical chemistry and laboratory medicine 医学-医学实验技术
CiteScore
11.30
自引率
16.20%
发文量
306
审稿时长
3 months
期刊介绍: Clinical Chemistry and Laboratory Medicine (CCLM) publishes articles on novel teaching and training methods applicable to laboratory medicine. CCLM welcomes contributions on the progress in fundamental and applied research and cutting-edge clinical laboratory medicine. It is one of the leading journals in the field, with an impact factor over 3. CCLM is issued monthly, and it is published in print and electronically. CCLM is the official journal of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) and publishes regularly EFLM recommendations and news. CCLM is the official journal of the National Societies from Austria (ÖGLMKC); Belgium (RBSLM); Germany (DGKL); Hungary (MLDT); Ireland (ACBI); Italy (SIBioC); Portugal (SPML); and Slovenia (SZKK); and it is affiliated to AACB (Australia) and SFBC (France). Topics: - clinical biochemistry - clinical genomics and molecular biology - clinical haematology and coagulation - clinical immunology and autoimmunity - clinical microbiology - drug monitoring and analysis - evaluation of diagnostic biomarkers - disease-oriented topics (cardiovascular disease, cancer diagnostics, diabetes) - new reagents, instrumentation and technologies - new methodologies - reference materials and methods - reference values and decision limits - quality and safety in laboratory medicine - translational laboratory medicine - clinical metrology Follow @cclm_degruyter on Twitter!
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信