David Wright MD , Carol Lee MD , Steven S. Shin MD , Michelle H. McGarry MS , Thay Q. Lee PhD
{"title":"Biomechanical Comparison of Volar Plate Repair Versus Volar Plate Repair With Suture Tape Augmentation at the Finger Proximal Interphalangeal Joint","authors":"David Wright MD , Carol Lee MD , Steven S. Shin MD , Michelle H. McGarry MS , Thay Q. Lee PhD","doi":"10.1016/j.jhsa.2024.11.005","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div><span>The purpose of this study was to perform a biomechanical comparison of volar plate repair alone versus volar plate repair with suture tape augmentation in a </span>hyperextension laxity injury model at the proximal interphalangeal (PIP) joint.</div></div><div><h3>Methods</h3><div>Ten matched cadaveric fingers were obtained from five cadavers (average age, 59 ± 7 years). The specimens underwent 5 and 10 N·cm of extension load at the PIP joint to measure the laxity of the intact joint. Next, an injury model was created by incising the proximal volar plate and loading the specimen on a testing machine to 30° of hyperextension; laxity testing was repeated. Within each matched pair, one side was used for volar plate repair, and the contralateral side was used for volar plate repair with suture tape augmentation. Laxity measurements were repeated. The specimens were then loaded from 2 to 5 N·cm for 30 cycles, and then loaded to failure.</div></div><div><h3>Results</h3><div>In both groups, extension angle significantly increased following PIP joint injury. Both repair groups significantly decreased extension angle compared with injury. Specimens that underwent volar plate repair with suture tape augmentation demonstrated significantly increased stiffness at 10, 20, and 30 cycles compared with volar plate repair alone (3.4, 3.5, and 3.6 N·cm/° vs 2.5, 2.5, and 2.6 N·cm/°, respectively), a higher yield load (16.7 vs 12.4 N·cm), and ultimate load (25.9 vs 19.1 N·cm) and absorbed more energy at ultimate load (4.1 vs 2.6 N·cm).</div></div><div><h3>Conclusions</h3><div>Suture tape augmentation increased construct stiffness, yield load, load to failure, and ultimate load in this biomechanical study and may offer additional support in volar plate repair for chronic PIP joint hyperextension laxity.</div></div><div><h3>Clinical relevance</h3><div>This finding lends support to using suture tape as an augment to produce a stronger PIP joint repair, potentially leading to an expedited recovery and earlier return to activities.</div></div>","PeriodicalId":54815,"journal":{"name":"Journal of Hand Surgery-American Volume","volume":"50 10","pages":"Pages 1273.e1-1273.e7"},"PeriodicalIF":2.1000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hand Surgery-American Volume","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0363502324005483","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose
The purpose of this study was to perform a biomechanical comparison of volar plate repair alone versus volar plate repair with suture tape augmentation in a hyperextension laxity injury model at the proximal interphalangeal (PIP) joint.
Methods
Ten matched cadaveric fingers were obtained from five cadavers (average age, 59 ± 7 years). The specimens underwent 5 and 10 N·cm of extension load at the PIP joint to measure the laxity of the intact joint. Next, an injury model was created by incising the proximal volar plate and loading the specimen on a testing machine to 30° of hyperextension; laxity testing was repeated. Within each matched pair, one side was used for volar plate repair, and the contralateral side was used for volar plate repair with suture tape augmentation. Laxity measurements were repeated. The specimens were then loaded from 2 to 5 N·cm for 30 cycles, and then loaded to failure.
Results
In both groups, extension angle significantly increased following PIP joint injury. Both repair groups significantly decreased extension angle compared with injury. Specimens that underwent volar plate repair with suture tape augmentation demonstrated significantly increased stiffness at 10, 20, and 30 cycles compared with volar plate repair alone (3.4, 3.5, and 3.6 N·cm/° vs 2.5, 2.5, and 2.6 N·cm/°, respectively), a higher yield load (16.7 vs 12.4 N·cm), and ultimate load (25.9 vs 19.1 N·cm) and absorbed more energy at ultimate load (4.1 vs 2.6 N·cm).
Conclusions
Suture tape augmentation increased construct stiffness, yield load, load to failure, and ultimate load in this biomechanical study and may offer additional support in volar plate repair for chronic PIP joint hyperextension laxity.
Clinical relevance
This finding lends support to using suture tape as an augment to produce a stronger PIP joint repair, potentially leading to an expedited recovery and earlier return to activities.
期刊介绍:
The Journal of Hand Surgery publishes original, peer-reviewed articles related to the pathophysiology, diagnosis, and treatment of diseases and conditions of the upper extremity; these include both clinical and basic science studies, along with case reports. Special features include Review Articles (including Current Concepts and The Hand Surgery Landscape), Reviews of Books and Media, and Letters to the Editor.