Inter-rater Reliability of Ultrasonographic Measurements of Optic Nerve Sheath Diameter Performed by Emergency Nurses.

IF 1.8 4区 医学 Q2 EMERGENCY MEDICINE
Turgay Yılmaz Kilic, Yesim Eyler, Birdal Güllüpınar, Murat Yesilaras, Serhat Koran
{"title":"Inter-rater Reliability of Ultrasonographic Measurements of Optic Nerve Sheath Diameter Performed by Emergency Nurses.","authors":"Turgay Yılmaz Kilic, Yesim Eyler, Birdal Güllüpınar, Murat Yesilaras, Serhat Koran","doi":"10.1016/j.jen.2024.11.002","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>We aimed to determine the inter-rater reliability of ultrasonographic optic nerve sheath diameter measurements performed by emergency nurses.</p><p><strong>Methods: </strong>Point-of-care ultrasound of the optic nerve sheath diameter measurements were performed in B-mode using a 10 MHz linear probe. The emergency nurses had no previous experience in ultrasonography. Emergency nurses performed sonographic measurements on patients in groups of 2. First, 1 emergency nurse measured optic nerve sheath diameter in both the right and left eyes of the patient, and then the other emergency nurse measured optic nerve sheath diameter in the right and left eyes of the same patient. Thus, a total of 4 optic nerve sheath diameter measurements were made by 2 emergency nurses in both eyes of 1 patient. Four emergency nurses measured optic nerve sheath diameter in 25 separate patients. As a result, a total of 600 optic nerve sheath diameter values were obtained in 150 patients. Each emergency nurse recorded their results on data collection forms and was blinded to each other's measurements.</p><p><strong>Results: </strong>The median optic nerve sheath diameter was 3.6 mm (interquartile range, 0.6). The median optic nerve sheath diameters of males and females were 3.7 mm (interquartile range, 0.6) and 3.5 mm (interquartile range, 0.6), respectively. The intraclass correlation coefficient was 0.89 (95% CI, 0.86-0.91). The intraclass correlation coefficient values for the optic nerve sheath diameter measurements of the right and left eyes were 0.89 (95% CI, 0.85-0.92) and 0.88 (95% CI, 0.83-0.91), respectively.</p><p><strong>Discussion: </strong>There is good inter-rater reliability among emergency nurses with no previous experience in measuring the optic nerve sheath diameter with point-of-care ultrasound.</p>","PeriodicalId":51082,"journal":{"name":"Journal of Emergency Nursing","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Emergency Nursing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jen.2024.11.002","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: We aimed to determine the inter-rater reliability of ultrasonographic optic nerve sheath diameter measurements performed by emergency nurses.

Methods: Point-of-care ultrasound of the optic nerve sheath diameter measurements were performed in B-mode using a 10 MHz linear probe. The emergency nurses had no previous experience in ultrasonography. Emergency nurses performed sonographic measurements on patients in groups of 2. First, 1 emergency nurse measured optic nerve sheath diameter in both the right and left eyes of the patient, and then the other emergency nurse measured optic nerve sheath diameter in the right and left eyes of the same patient. Thus, a total of 4 optic nerve sheath diameter measurements were made by 2 emergency nurses in both eyes of 1 patient. Four emergency nurses measured optic nerve sheath diameter in 25 separate patients. As a result, a total of 600 optic nerve sheath diameter values were obtained in 150 patients. Each emergency nurse recorded their results on data collection forms and was blinded to each other's measurements.

Results: The median optic nerve sheath diameter was 3.6 mm (interquartile range, 0.6). The median optic nerve sheath diameters of males and females were 3.7 mm (interquartile range, 0.6) and 3.5 mm (interquartile range, 0.6), respectively. The intraclass correlation coefficient was 0.89 (95% CI, 0.86-0.91). The intraclass correlation coefficient values for the optic nerve sheath diameter measurements of the right and left eyes were 0.89 (95% CI, 0.85-0.92) and 0.88 (95% CI, 0.83-0.91), respectively.

Discussion: There is good inter-rater reliability among emergency nurses with no previous experience in measuring the optic nerve sheath diameter with point-of-care ultrasound.

急诊护士视神经鞘直径超声测量的内部可靠性。
简介:我们的目的是确定急诊护士超声视神经鞘直径测量的内部可靠性。方法:使用10 MHz线性探头,在b模式下进行视神经鞘直径的即时超声测量。急诊护士没有超声检查经验。急诊护士对每组2名患者进行超声测量。先由1名急诊护士分别测量患者左右眼视神经鞘直径,再由另一名急诊护士分别测量同一患者左右眼视神经鞘直径。因此,2名急诊护士对1例患者的双眼共进行了4次视神经鞘直径测量。四名急诊护士分别测量了25名患者的视神经鞘直径。结果,150例患者共获得600个视神经鞘直径值。每个急救护士都将他们的结果记录在数据收集表上,并且对彼此的测量结果一无所知。结果:视神经鞘正中径为3.6 mm(四分位数间距0.6)。男性和女性的正中视神经鞘直径分别为3.7 mm(四分位差0.6)和3.5 mm(四分位差0.6)。类内相关系数为0.89 (95% CI, 0.86 ~ 0.91)。右眼和左眼视神经鞘直径测量的类内相关系数分别为0.89 (95% CI, 0.85-0.92)和0.88 (95% CI, 0.83-0.91)。讨论:急诊护士在没有使用即时超声测量视神经鞘直径经验的情况下,有良好的量表间信度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.10
自引率
11.80%
发文量
132
审稿时长
46 days
期刊介绍: The Journal of Emergency Nursing, the official journal of the Emergency Nurses Association (ENA), is committed to the dissemination of high quality, peer-reviewed manuscripts relevant to all areas of emergency nursing practice across the lifespan. Journal content includes clinical topics, integrative or systematic literature reviews, research, and practice improvement initiatives that provide emergency nurses globally with implications for translation of new knowledge into practice. The Journal also includes focused sections such as case studies, pharmacology/toxicology, injury prevention, trauma, triage, quality and safety, pediatrics and geriatrics. The Journal aims to mirror the goal of ENA to promote: community, governance and leadership, knowledge, quality and safety, and advocacy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信