Comparison of Adequacy of Anaesthesia (AoA) monitors with CONOX® monitor regarding sevoflurane consumption during routine general anaesthesia: A randomised clinical trial.

IF 2.9 Q1 ANESTHESIOLOGY
Indian Journal of Anaesthesia Pub Date : 2024-11-01 Epub Date: 2024-10-26 DOI:10.4103/ija.ija_174_24
Rajendran Arulkumaran, Anusha Cherian, Aswini Kuberan, Prasanna Udupi Bidkar
{"title":"Comparison of Adequacy of Anaesthesia (AoA) monitors with CONOX<sup>®</sup> monitor regarding sevoflurane consumption during routine general anaesthesia: A randomised clinical trial.","authors":"Rajendran Arulkumaran, Anusha Cherian, Aswini Kuberan, Prasanna Udupi Bidkar","doi":"10.4103/ija.ija_174_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aims: </strong>Adequacy of Anaesthesia (AoA) and CONOX<sup>®</sup> are combined monitors that assess levels of anaesthesia and analgesia and give a comprehensive score. No studies have measured and compared the total consumption of inhaled anaesthetic agents while using these monitors. We designed a study to compare AoA and CONOX in terms of sevoflurane usage, fentanyl usage and recovery from the effects of anaesthesia.</p><p><strong>Methods: </strong>A randomised trial was conducted in 58 patients. Group A (<i>n</i> = 31) patients were monitored with AoA, and Group C (<i>n</i> = 27) patients were monitored with CONOX. Sevoflurane was titrated to maintain a state entropy value of 40-60 in AoA and a Quantium consciousness index (qCON) value of 40-60 in CONOX. Similarly, fentanyl was titrated with bolus doses of 0.5 μg/kg to maintain a surgical pleth index value of 40-60 in AoA and Quantium noxious index (qNOX) value of 40-60 in CONOX. Intraoperative awareness was assessed postoperatively using a modified Brice questionnaire. The <i>t</i>-test or Chi-square test was used to compare the parameters between the groups.</p><p><strong>Results: </strong>Mean sevoflurane consumption was similar between AoA and CONOX groups [13.2 (standard deviation {SD}: 3.9) (95% confidence interval {CI}:11.8, 14.5) versus 14.4 (SD: 3.7) (95% CI: 13.0, 15.7) ml/h] (<i>P</i> = 0.236). Fentanyl usage was higher in the AoA group compared to the CONOX group [146.2 (SD: 34.28) (95% CI: 134.13, 158.26) versus 128.2 (SD: 26.7) (95% CI: 118.12, 138.27) μg] (<i>P</i> = 0.031). The emergence time and haemodynamic instability events were similar between AoA and CONOX.</p><p><strong>Conclusion: </strong>Both AoA and CONOX measure anaesthetic depth similarly. However, interpreting qNOX values requires caution, as the patient's consciousness status influences them.</p>","PeriodicalId":13339,"journal":{"name":"Indian Journal of Anaesthesia","volume":"68 11","pages":"996-1002"},"PeriodicalIF":2.9000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11626886/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Anaesthesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ija.ija_174_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/26 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and aims: Adequacy of Anaesthesia (AoA) and CONOX® are combined monitors that assess levels of anaesthesia and analgesia and give a comprehensive score. No studies have measured and compared the total consumption of inhaled anaesthetic agents while using these monitors. We designed a study to compare AoA and CONOX in terms of sevoflurane usage, fentanyl usage and recovery from the effects of anaesthesia.

Methods: A randomised trial was conducted in 58 patients. Group A (n = 31) patients were monitored with AoA, and Group C (n = 27) patients were monitored with CONOX. Sevoflurane was titrated to maintain a state entropy value of 40-60 in AoA and a Quantium consciousness index (qCON) value of 40-60 in CONOX. Similarly, fentanyl was titrated with bolus doses of 0.5 μg/kg to maintain a surgical pleth index value of 40-60 in AoA and Quantium noxious index (qNOX) value of 40-60 in CONOX. Intraoperative awareness was assessed postoperatively using a modified Brice questionnaire. The t-test or Chi-square test was used to compare the parameters between the groups.

Results: Mean sevoflurane consumption was similar between AoA and CONOX groups [13.2 (standard deviation {SD}: 3.9) (95% confidence interval {CI}:11.8, 14.5) versus 14.4 (SD: 3.7) (95% CI: 13.0, 15.7) ml/h] (P = 0.236). Fentanyl usage was higher in the AoA group compared to the CONOX group [146.2 (SD: 34.28) (95% CI: 134.13, 158.26) versus 128.2 (SD: 26.7) (95% CI: 118.12, 138.27) μg] (P = 0.031). The emergence time and haemodynamic instability events were similar between AoA and CONOX.

Conclusion: Both AoA and CONOX measure anaesthetic depth similarly. However, interpreting qNOX values requires caution, as the patient's consciousness status influences them.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.20
自引率
44.80%
发文量
210
审稿时长
36 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信