Development and validation of a liquid chromatography-tandem mass spectrometry assay for the simultaneous analysis of isoniazid and pyrazinamide in cerebrospinal fluid.

IF 3.1 3区 医学 Q2 CHEMISTRY, ANALYTICAL
Sydwell Poulo Maputla, Anton Joubert, Sandra Castel, Marthinus van der Merwe, Edda Zangenberg, Sean Wasserman, Kelly E Dooley, Lubbe Wiesner
{"title":"Development and validation of a liquid chromatography-tandem mass spectrometry assay for the simultaneous analysis of isoniazid and pyrazinamide in cerebrospinal fluid.","authors":"Sydwell Poulo Maputla, Anton Joubert, Sandra Castel, Marthinus van der Merwe, Edda Zangenberg, Sean Wasserman, Kelly E Dooley, Lubbe Wiesner","doi":"10.1016/j.jpba.2024.116613","DOIUrl":null,"url":null,"abstract":"<p><p>For the effective treatment of tuberculosis with first-line anti-tubercular drugs, drug concentrations need to be measured at the site of infection to determine drug exposure. To enable the measurement of the anti-tuberculosis drugs isoniazid and pyrazinamide in the nervous system of patients with tuberculous meningitis, an analytical method was developed and validated for the quantification of these drugs in human cerebrospinal fluid. Samples were prepared by solid phase extraction using Strata-X polymeric extraction plates. The analytes were separated by high-performance liquid chromatography on an Atlantis T3, 100 A, 3 µm, 2.1 mm × 100 mm analytical column with gradient elution, employing a mobile phase that consisted of acetonitrile-methanol-formic acid (50:50:0.1, v/v/v), at a flowrate of 0.25 mL/min. The total run time was 4.5 minutes, and the average retention times of isoniazid and pyrazinamide were 1.1 and 1.3 min, respectively. The analytes and their respective deuterated internal standards were detected on a Sciex API4000 triple quadrupole mass spectrometer applying positive electrospray ionization with multiple reaction monitoring as the detection mode. The method was validated according to the FDA and EMA guidelines. The method was demonstrated to be accurate, reproducible, and robust, showing the necessary sensitivity and specificity for the quantification of isoniazid and pyrazinamide in cerebrospinal fluid. The method was successfully applied to analyze clinical samples from the LASER-TBM and TBM-KIDS clinical studies.</p>","PeriodicalId":16685,"journal":{"name":"Journal of pharmaceutical and biomedical analysis","volume":"255 ","pages":"116613"},"PeriodicalIF":3.1000,"publicationDate":"2025-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pharmaceutical and biomedical analysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jpba.2024.116613","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/4 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

For the effective treatment of tuberculosis with first-line anti-tubercular drugs, drug concentrations need to be measured at the site of infection to determine drug exposure. To enable the measurement of the anti-tuberculosis drugs isoniazid and pyrazinamide in the nervous system of patients with tuberculous meningitis, an analytical method was developed and validated for the quantification of these drugs in human cerebrospinal fluid. Samples were prepared by solid phase extraction using Strata-X polymeric extraction plates. The analytes were separated by high-performance liquid chromatography on an Atlantis T3, 100 A, 3 µm, 2.1 mm × 100 mm analytical column with gradient elution, employing a mobile phase that consisted of acetonitrile-methanol-formic acid (50:50:0.1, v/v/v), at a flowrate of 0.25 mL/min. The total run time was 4.5 minutes, and the average retention times of isoniazid and pyrazinamide were 1.1 and 1.3 min, respectively. The analytes and their respective deuterated internal standards were detected on a Sciex API4000 triple quadrupole mass spectrometer applying positive electrospray ionization with multiple reaction monitoring as the detection mode. The method was validated according to the FDA and EMA guidelines. The method was demonstrated to be accurate, reproducible, and robust, showing the necessary sensitivity and specificity for the quantification of isoniazid and pyrazinamide in cerebrospinal fluid. The method was successfully applied to analyze clinical samples from the LASER-TBM and TBM-KIDS clinical studies.

液相色谱-串联质谱法同时分析脑脊液中异烟肼和吡嗪酰胺的建立和验证。
为了用一线抗结核药物有效治疗结核病,需要在感染部位测量药物浓度,以确定药物暴露。为了测定结核性脑膜炎患者神经系统中抗结核药物异烟肼和吡嗪酰胺的含量,建立了一种测定人脑脊液中抗结核药物含量的分析方法并进行了验证。采用Strata-X聚合萃取板固相萃取制备样品。采用高效液相色谱法,色谱柱为Atlantis T3, 100 A, 3 µm, 2.1 mm × 100 mm,流动相为乙腈-甲醇-甲酸(50:50:0.1,v/v/v),梯度洗脱,流速为0.25 mL/min。总运行时间为4.5 min,异烟肼和吡嗪酰胺的平均保留时间分别为1.1和1.3 min。分析物及其各自的氘化内标在Sciex API4000三重四极杆质谱仪上进行检测,采用正电喷雾电离,多重反应监测为检测模式。该方法根据FDA和EMA指南进行了验证。结果表明,该方法准确、重现性好、稳健性好,对脑脊液中异烟肼和吡嗪酰胺的定量具有必要的敏感性和特异性。该方法已成功应用于LASER-TBM和TBM-KIDS临床研究的临床样品分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.70
自引率
5.90%
发文量
588
审稿时长
37 days
期刊介绍: This journal is an international medium directed towards the needs of academic, clinical, government and industrial analysis by publishing original research reports and critical reviews on pharmaceutical and biomedical analysis. It covers the interdisciplinary aspects of analysis in the pharmaceutical, biomedical and clinical sciences, including developments in analytical methodology, instrumentation, computation and interpretation. Submissions on novel applications focusing on drug purity and stability studies, pharmacokinetics, therapeutic monitoring, metabolic profiling; drug-related aspects of analytical biochemistry and forensic toxicology; quality assurance in the pharmaceutical industry are also welcome. Studies from areas of well established and poorly selective methods, such as UV-VIS spectrophotometry (including derivative and multi-wavelength measurements), basic electroanalytical (potentiometric, polarographic and voltammetric) methods, fluorimetry, flow-injection analysis, etc. are accepted for publication in exceptional cases only, if a unique and substantial advantage over presently known systems is demonstrated. The same applies to the assay of simple drug formulations by any kind of methods and the determination of drugs in biological samples based merely on spiked samples. Drug purity/stability studies should contain information on the structure elucidation of the impurities/degradants.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信