Roughhousing with Ions: Surface-Induced Dissociation and Electron Capture Dissociation as Diagnostics of Q-Cyclic IMS-TOF Instrument Tuning Gentleness.

IF 3.1 2区 化学 Q2 BIOCHEMICAL RESEARCH METHODS
Andrew J Arslanian, Vicki H Wysocki
{"title":"Roughhousing with Ions: Surface-Induced Dissociation and Electron Capture Dissociation as Diagnostics of Q-Cyclic IMS-TOF Instrument Tuning Gentleness.","authors":"Andrew J Arslanian, Vicki H Wysocki","doi":"10.1021/jasms.4c00417","DOIUrl":null,"url":null,"abstract":"<p><p>Native mass spectrometry can characterize a range of biomolecular features pertinent to structural biology, including intact mass, stoichiometry, ligand-bound states, and topology. However, when an instrument's ionization source is tuned to maximize signal intensity or adduct removal, it is possible that the biomolecular complex's tertiary and quaternary structures can be rearranged in a way that no longer reflect its native-like conformation. This could affect downstream ion activation experiments, leading to erroneous conclusions about the native-like structure. One activation strategy is surface-induced dissociation (SID), which generally causes native-like protein complexes to dissociate along the weakest subunit interfaces, revealing critical information about the complex's native-like topology and subunit connectivity. If the quaternary structure has been disturbed, then the SID fingerprint will shift as well. Thus, SID was used to diagnose source-induced quaternary structure rearrangement and help tune an instrument's source and other upstream transmission regions to strike the balance between signal intensity, adduct removal, and conserving the native-like structure. Complementary to SID, electron-capture dissociation (ECD) can also diagnose rearranged quaternary structures and was used after in-source activation to confirm that the subunit interfaces were rearranged, opening the structure to electron capture and subsequent dissociation. These results provide a valuable guide for new practitioners of native mass spectrometry and highlight the importance of using standard protein complexes when tuning new instrument platforms for optimal native mass spectrometry performance.</p>","PeriodicalId":672,"journal":{"name":"Journal of the American Society for Mass Spectrometry","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2024-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Society for Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/jasms.4c00417","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Native mass spectrometry can characterize a range of biomolecular features pertinent to structural biology, including intact mass, stoichiometry, ligand-bound states, and topology. However, when an instrument's ionization source is tuned to maximize signal intensity or adduct removal, it is possible that the biomolecular complex's tertiary and quaternary structures can be rearranged in a way that no longer reflect its native-like conformation. This could affect downstream ion activation experiments, leading to erroneous conclusions about the native-like structure. One activation strategy is surface-induced dissociation (SID), which generally causes native-like protein complexes to dissociate along the weakest subunit interfaces, revealing critical information about the complex's native-like topology and subunit connectivity. If the quaternary structure has been disturbed, then the SID fingerprint will shift as well. Thus, SID was used to diagnose source-induced quaternary structure rearrangement and help tune an instrument's source and other upstream transmission regions to strike the balance between signal intensity, adduct removal, and conserving the native-like structure. Complementary to SID, electron-capture dissociation (ECD) can also diagnose rearranged quaternary structures and was used after in-source activation to confirm that the subunit interfaces were rearranged, opening the structure to electron capture and subsequent dissociation. These results provide a valuable guide for new practitioners of native mass spectrometry and highlight the importance of using standard protein complexes when tuning new instrument platforms for optimal native mass spectrometry performance.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.50
自引率
9.40%
发文量
257
审稿时长
1 months
期刊介绍: The Journal of the American Society for Mass Spectrometry presents research papers covering all aspects of mass spectrometry, incorporating coverage of fields of scientific inquiry in which mass spectrometry can play a role. Comprehensive in scope, the journal publishes papers on both fundamentals and applications of mass spectrometry. Fundamental subjects include instrumentation principles, design, and demonstration, structures and chemical properties of gas-phase ions, studies of thermodynamic properties, ion spectroscopy, chemical kinetics, mechanisms of ionization, theories of ion fragmentation, cluster ions, and potential energy surfaces. In addition to full papers, the journal offers Communications, Application Notes, and Accounts and Perspectives
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信