Early and Mid-Term Outcomes of Coronary Protection during Transcatheter Aortic Valve Replacement: A Single-Center Retrospective Analysis.

IF 1.9 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Reviews in cardiovascular medicine Pub Date : 2024-11-20 eCollection Date: 2024-11-01 DOI:10.31083/j.rcm2511407
Jiawei Zhou, Yuehuan Li, Jinglun Shen, Kaisheng Wu, Jiangang Wang, Yi Yu, Haibo Zhang
{"title":"Early and Mid-Term Outcomes of Coronary Protection during Transcatheter Aortic Valve Replacement: A Single-Center Retrospective Analysis.","authors":"Jiawei Zhou, Yuehuan Li, Jinglun Shen, Kaisheng Wu, Jiangang Wang, Yi Yu, Haibo Zhang","doi":"10.31083/j.rcm2511407","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Coronary obstruction (CO) is a fatal complication in transcatheter aortic valve replacement (TAVR). However, data on the outcomes and details of coronary protection (CP) use in TAVR are limited.</p><p><strong>Methods: </strong>We retrospectively analyzed the patients who had undergone CP during TAVR at our tertiary cardiac center from March 2017 to January 2024. CP was achieved by an undeployed coronary balloon or stent positioned within the coronary artery, which releases the stent at CO occurrence. Patients' computed tomography (CT) evaluation reports and perioperative and follow-up outcomes were reviewed.</p><p><strong>Results: </strong>A total of 33 out of 493 patients (6.7%) underwent CP during TAVR due to the high risk of CO based on preoperative CT analysis. The mean sinus dimensions measured 30.1 ± 3.6 mm, 29.2 ± 3.4 mm, and 30.4 ± 3.7 mm for the left, right, and non-coronary sinus, respectively. The average left main height was 11.7 mm, and the right coronary height was 14 mm. Self-expanding valves were used in 93.9% of the patients. Coronary balloons were used for CP in 30 patients, whereas undeployed coronary stents were used in three cases. A total of 36 coronary arteries were protected, including 28 left coronary arteries alone, two right coronary arteries alone, and three dual coronary arteries. Eight patients (24.2%) developed CO and underwent stent release. The in-hospital and 30-day all-cause mortality rates were 9.1% and 0%, respectively. The median follow-up time was 10 months, and only one patient died 2 months after discharge due to stroke during the follow-up.</p><p><strong>Conclusions: </strong>Pre-emptive coronary balloons or stents for CP allow for revascularization in the shortest possible time in the event of CO. Early and mid-term outcomes of CP during TAVR in patients with a high risk of CO show that CP is safe and feasible.</p>","PeriodicalId":20989,"journal":{"name":"Reviews in cardiovascular medicine","volume":"25 11","pages":"407"},"PeriodicalIF":1.9000,"publicationDate":"2024-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11607484/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Reviews in cardiovascular medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.31083/j.rcm2511407","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Coronary obstruction (CO) is a fatal complication in transcatheter aortic valve replacement (TAVR). However, data on the outcomes and details of coronary protection (CP) use in TAVR are limited.

Methods: We retrospectively analyzed the patients who had undergone CP during TAVR at our tertiary cardiac center from March 2017 to January 2024. CP was achieved by an undeployed coronary balloon or stent positioned within the coronary artery, which releases the stent at CO occurrence. Patients' computed tomography (CT) evaluation reports and perioperative and follow-up outcomes were reviewed.

Results: A total of 33 out of 493 patients (6.7%) underwent CP during TAVR due to the high risk of CO based on preoperative CT analysis. The mean sinus dimensions measured 30.1 ± 3.6 mm, 29.2 ± 3.4 mm, and 30.4 ± 3.7 mm for the left, right, and non-coronary sinus, respectively. The average left main height was 11.7 mm, and the right coronary height was 14 mm. Self-expanding valves were used in 93.9% of the patients. Coronary balloons were used for CP in 30 patients, whereas undeployed coronary stents were used in three cases. A total of 36 coronary arteries were protected, including 28 left coronary arteries alone, two right coronary arteries alone, and three dual coronary arteries. Eight patients (24.2%) developed CO and underwent stent release. The in-hospital and 30-day all-cause mortality rates were 9.1% and 0%, respectively. The median follow-up time was 10 months, and only one patient died 2 months after discharge due to stroke during the follow-up.

Conclusions: Pre-emptive coronary balloons or stents for CP allow for revascularization in the shortest possible time in the event of CO. Early and mid-term outcomes of CP during TAVR in patients with a high risk of CO show that CP is safe and feasible.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Reviews in cardiovascular medicine
Reviews in cardiovascular medicine 医学-心血管系统
CiteScore
2.70
自引率
3.70%
发文量
377
审稿时长
1 months
期刊介绍: RCM is an international, peer-reviewed, open access journal. RCM publishes research articles, review papers and short communications on cardiovascular medicine as well as research on cardiovascular disease. We aim to provide a forum for publishing papers which explore the pathogenesis and promote the progression of cardiac and vascular diseases. We also seek to establish an interdisciplinary platform, focusing on translational issues, to facilitate the advancement of research, clinical treatment and diagnostic procedures. Heart surgery, cardiovascular imaging, risk factors and various clinical cardiac & vascular research will be considered.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信