Radiation exposure during basivertebral nerve radiofrequency ablations

Andrew R. Stephens, Nicholas R. Bender, Ramzi El-Hassan, Adem F. Aktas
{"title":"Radiation exposure during basivertebral nerve radiofrequency ablations","authors":"Andrew R. Stephens,&nbsp;Nicholas R. Bender,&nbsp;Ramzi El-Hassan,&nbsp;Adem F. Aktas","doi":"10.1016/j.inpm.2024.100531","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Basivertebral nerve radiofrequency ablations (BVNRFA) is a relatively new procedure that has demonstrated positive effects to treat chronic low back pain. Fluoroscopy guidance is utilized to access the vertebral body via the pedicle and confirm the correct location of the probe for ablation. Radiation exposure during this procedure has not been previously reported.</div></div><div><h3>Objective</h3><div>The purpose of this study was to evaluate the average fluoroscopic time and radiation exposure during BVNRFA.</div></div><div><h3>Methods</h3><div>Patients treated with BVNRFA that had failed conservative treatment, with primarily midline back pain, and corroborating Modic type I or Modic type II changes on MRI at a tertiary academic spine center were retrospectively analyzed. Chart review was conducted to obtain patient demographics, fluoroscopic time and radiation exposure, involvement of trainees, and vertebral levels treated. Average fluoroscopic and radiation exposure was calculated.</div></div><div><h3>Results</h3><div>A total of 55 patients were included in this study. The average fluoroscopic time was 152.5 s (±84.3 s). The average cumulative dose was 70.3 mGy (±53.0 mGy) and the average dose area product was 7.9 mGy·cm2 (±5.2 mGy·cm2).</div></div><div><h3>Conclusions</h3><div>Our study demonstrated that the average fluoroscopic time during BVNRFA to be about 2 and a half minutes.</div></div>","PeriodicalId":100727,"journal":{"name":"Interventional Pain Medicine","volume":"3 4","pages":"Article 100531"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Pain Medicine","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772594424001523","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Basivertebral nerve radiofrequency ablations (BVNRFA) is a relatively new procedure that has demonstrated positive effects to treat chronic low back pain. Fluoroscopy guidance is utilized to access the vertebral body via the pedicle and confirm the correct location of the probe for ablation. Radiation exposure during this procedure has not been previously reported.

Objective

The purpose of this study was to evaluate the average fluoroscopic time and radiation exposure during BVNRFA.

Methods

Patients treated with BVNRFA that had failed conservative treatment, with primarily midline back pain, and corroborating Modic type I or Modic type II changes on MRI at a tertiary academic spine center were retrospectively analyzed. Chart review was conducted to obtain patient demographics, fluoroscopic time and radiation exposure, involvement of trainees, and vertebral levels treated. Average fluoroscopic and radiation exposure was calculated.

Results

A total of 55 patients were included in this study. The average fluoroscopic time was 152.5 s (±84.3 s). The average cumulative dose was 70.3 mGy (±53.0 mGy) and the average dose area product was 7.9 mGy·cm2 (±5.2 mGy·cm2).

Conclusions

Our study demonstrated that the average fluoroscopic time during BVNRFA to be about 2 and a half minutes.
椎基神经射频消融期间的辐射暴露
背景:椎体神经射频消融(BVNRFA)是一种相对较新的治疗方法,已被证明对治疗慢性腰痛有积极作用。利用透视引导通过椎弓根进入椎体,并确定探针的正确位置进行消融。在此过程中的辐射暴露以前没有报道。目的评价BVNRFA期间的平均透视时间和辐射暴露情况。方法回顾性分析接受BVNRFA治疗的患者,这些患者保守治疗失败,主要是腰中线疼痛,并且在三级学术脊柱中心的MRI上证实了Modic I型或Modic II型改变。进行图表回顾,以获得患者的人口统计资料,透视时间和辐射暴露,受训者的参与,以及治疗的椎体水平。计算平均透视和辐射暴露。结果本研究共纳入55例患者。平均荧光时间152.5 s(±84.3 s),平均累积剂量70.3 mGy(±53.0 mGy),平均剂量面积积7.9 mGy·cm2(±5.2 mGy·cm2)。结论我们的研究表明,BVNRFA期间的平均透视时间约为2分半钟。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信