The effect of smart glasses combined with ultrasound on radial arterial catheterization: a randomized controlled trial.

IF 2.3 3区 医学 Q2 ANESTHESIOLOGY
Yan Wang, Mingjing Chen, Ting Zou, Yan Weng, Wenjie Mao, Qing Zhong, Haibo Song
{"title":"The effect of smart glasses combined with ultrasound on radial arterial catheterization: a randomized controlled trial.","authors":"Yan Wang, Mingjing Chen, Ting Zou, Yan Weng, Wenjie Mao, Qing Zhong, Haibo Song","doi":"10.1186/s12871-024-02828-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The integration of smart glasses with ultrasound technology offers a novel approach to improve the efficiency of radial arterial catheterization. Few studies have investigated the effectiveness of smart glasses in enhancing procedural outcomes in a clinical setting. This study aims to assess whether smart glasses combined with ultrasound can improve the initial success rate of radial artery catheterization compared to traditional ultrasound-guided methods in adults.</p><p><strong>Methods: </strong>This single-blinded, randomized controlled trial enrolled patients aged 18-70 with American Society of Anesthesiologists physical status I-III, who required radial artery catheterization as part of their procedure under general anesthesia. Patients were randomized 1:1 into the ultrasound group and the smart glasses group. Radial arterial catheterization was carried out by one of six anesthesiologists before general anesthesia. The primary endpoint was the first puncture success rate. Secondary endpoints included hand-eye coordination (measured by head rotations, probe repositioning and needle redirections), operator's satisfaction.</p><p><strong>Results: </strong>A total of 222 patients were analyzed, with the smart glasses group demonstrating a higher rate of first puncture success compared to the control group (88.3% [98/111] vs. 72.1% [80/111]; P = 0.002; relative risk [RR], 1.23; 95% CI (1.07, 1.40)). Hand-eye coordination improved significantly in the smart glasses group than the control group, including: fewer number of head rotations (0 [0, 0] vs. 3 [2, 6]; P < 0.001); fewer number of ultrasound probe repositioning (0 [0, 0] vs. 0 [0, 1]; P < 0.001); fewer number of needle redirections (0 [0, 1] vs. 1 [0, 3]; P < 0.001). The proportion of positive satisfaction (81 to 100 points) in the smart glasses group was higher (89.2% [99/111] vs. 69.4% [77/111]; P <  0.001; RR, 1.29; 95% CI (1.12, 1.48)).</p><p><strong>Conclusions: </strong>The use of smart glasses significantly improved the first puncture success rate, hand-eye coordination ability and operators' satisfaction in radial arterial catheterization.</p><p><strong>Trial registration: </strong>The study was registered at Chictr.org.cn with the number ChiCTR2400081399 on 29/02/2024.</p>","PeriodicalId":9190,"journal":{"name":"BMC Anesthesiology","volume":"24 1","pages":"444"},"PeriodicalIF":2.3000,"publicationDate":"2024-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11605872/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Anesthesiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12871-024-02828-8","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The integration of smart glasses with ultrasound technology offers a novel approach to improve the efficiency of radial arterial catheterization. Few studies have investigated the effectiveness of smart glasses in enhancing procedural outcomes in a clinical setting. This study aims to assess whether smart glasses combined with ultrasound can improve the initial success rate of radial artery catheterization compared to traditional ultrasound-guided methods in adults.

Methods: This single-blinded, randomized controlled trial enrolled patients aged 18-70 with American Society of Anesthesiologists physical status I-III, who required radial artery catheterization as part of their procedure under general anesthesia. Patients were randomized 1:1 into the ultrasound group and the smart glasses group. Radial arterial catheterization was carried out by one of six anesthesiologists before general anesthesia. The primary endpoint was the first puncture success rate. Secondary endpoints included hand-eye coordination (measured by head rotations, probe repositioning and needle redirections), operator's satisfaction.

Results: A total of 222 patients were analyzed, with the smart glasses group demonstrating a higher rate of first puncture success compared to the control group (88.3% [98/111] vs. 72.1% [80/111]; P = 0.002; relative risk [RR], 1.23; 95% CI (1.07, 1.40)). Hand-eye coordination improved significantly in the smart glasses group than the control group, including: fewer number of head rotations (0 [0, 0] vs. 3 [2, 6]; P < 0.001); fewer number of ultrasound probe repositioning (0 [0, 0] vs. 0 [0, 1]; P < 0.001); fewer number of needle redirections (0 [0, 1] vs. 1 [0, 3]; P < 0.001). The proportion of positive satisfaction (81 to 100 points) in the smart glasses group was higher (89.2% [99/111] vs. 69.4% [77/111]; P <  0.001; RR, 1.29; 95% CI (1.12, 1.48)).

Conclusions: The use of smart glasses significantly improved the first puncture success rate, hand-eye coordination ability and operators' satisfaction in radial arterial catheterization.

Trial registration: The study was registered at Chictr.org.cn with the number ChiCTR2400081399 on 29/02/2024.

求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Anesthesiology
BMC Anesthesiology ANESTHESIOLOGY-
CiteScore
3.50
自引率
4.50%
发文量
349
审稿时长
>12 weeks
期刊介绍: BMC Anesthesiology is an open access, peer-reviewed journal that considers articles on all aspects of anesthesiology, critical care, perioperative care and pain management, including clinical and experimental research into anesthetic mechanisms, administration and efficacy, technology and monitoring, and associated economic issues.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信