Junjie Ruan, Xiaotong Huang, Tong Wang, Xiuying Mai, Chuyan Lin, Fanghua Li, Yunfeng Li, Feng Chi, Bin Li
{"title":"Impact of belly board immobilization devices and body mass factor on setup displacement using daily cone-beam CT in rectal cancer radiotherapy.","authors":"Junjie Ruan, Xiaotong Huang, Tong Wang, Xiuying Mai, Chuyan Lin, Fanghua Li, Yunfeng Li, Feng Chi, Bin Li","doi":"10.1002/acm2.14573","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The objective of this study is to evaluate the impact of different belly board and daily changes in patient's body-mass factor (BMF) on setup displacement in radiotherapy for rectal cancer.</p><p><strong>Methods: </strong>Twenty-five patients were immobilized using the thermoplastic mask with belly board (TM-BB), and 30 used the vacuum bag cushion with belly board (VBC-BB), performing daily cone-beam computed tomography (CBCT) scans 625 times and 750 times, respectively. Daily pretreatment CBCT scans were registered to the planned CT images for BMF change determination and setup displacement measurement. Independent t-tests compared setup displacement between the two groups in left-right (LR), superior-inferior (SI), and anterior-posterior (AP) directions, as well as the BMF changes. The impact of daily BMF changes on setup displacement was evaluated using multivariate logistic regression and 10-fold cross-validation.</p><p><strong>Results: </strong>The setup displacement for TM-BB in the LR, SI, and AP directions were 0.31 ± 0.25, 0.58 ± 0.40, and 0.19 ± 0.18 cm, respectively, while VBC-BB showed 0.19 ± 0.15, 0.26 ± 0.22, and 0.36 ± 0.29 cm in the corresponding directions, respectively. Margins of planning target volume (PTV) for TM-BB were 8, 10, and 6 mm in LR, SI, and AP directions, while VBC-BB showed margins of 5,7, and 8 mm, respectively. The daily BMF changes for both groups were ranked in descending order as follows: sacral rotation angle (RS), hip lateral diameter (HLD), and hip anterior-posterior diameter (HAPD). HAPD was the main factor affecting setup displacement in both the AP and SI directions in TM-BB, while RS was the primary factor for setup displacement in the AP direction in VBC-BB.</p><p><strong>Conclusion: </strong>Compared with TM-BB, VBC-BB had a larger AP displacement but smaller in LR and SI displacement. Daily changes in BMF have distinct effects on setup displacement in different immobilization devices. Image-guided radiation therapy (IGRT) is highly recommended and BMF changes should be given consideration during radiotherapy.</p>","PeriodicalId":14989,"journal":{"name":"Journal of Applied Clinical Medical Physics","volume":" ","pages":"e14573"},"PeriodicalIF":2.0000,"publicationDate":"2024-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Clinical Medical Physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/acm2.14573","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: The objective of this study is to evaluate the impact of different belly board and daily changes in patient's body-mass factor (BMF) on setup displacement in radiotherapy for rectal cancer.
Methods: Twenty-five patients were immobilized using the thermoplastic mask with belly board (TM-BB), and 30 used the vacuum bag cushion with belly board (VBC-BB), performing daily cone-beam computed tomography (CBCT) scans 625 times and 750 times, respectively. Daily pretreatment CBCT scans were registered to the planned CT images for BMF change determination and setup displacement measurement. Independent t-tests compared setup displacement between the two groups in left-right (LR), superior-inferior (SI), and anterior-posterior (AP) directions, as well as the BMF changes. The impact of daily BMF changes on setup displacement was evaluated using multivariate logistic regression and 10-fold cross-validation.
Results: The setup displacement for TM-BB in the LR, SI, and AP directions were 0.31 ± 0.25, 0.58 ± 0.40, and 0.19 ± 0.18 cm, respectively, while VBC-BB showed 0.19 ± 0.15, 0.26 ± 0.22, and 0.36 ± 0.29 cm in the corresponding directions, respectively. Margins of planning target volume (PTV) for TM-BB were 8, 10, and 6 mm in LR, SI, and AP directions, while VBC-BB showed margins of 5,7, and 8 mm, respectively. The daily BMF changes for both groups were ranked in descending order as follows: sacral rotation angle (RS), hip lateral diameter (HLD), and hip anterior-posterior diameter (HAPD). HAPD was the main factor affecting setup displacement in both the AP and SI directions in TM-BB, while RS was the primary factor for setup displacement in the AP direction in VBC-BB.
Conclusion: Compared with TM-BB, VBC-BB had a larger AP displacement but smaller in LR and SI displacement. Daily changes in BMF have distinct effects on setup displacement in different immobilization devices. Image-guided radiation therapy (IGRT) is highly recommended and BMF changes should be given consideration during radiotherapy.
期刊介绍:
Journal of Applied Clinical Medical Physics is an international Open Access publication dedicated to clinical medical physics. JACMP welcomes original contributions dealing with all aspects of medical physics from scientists working in the clinical medical physics around the world. JACMP accepts only online submission.
JACMP will publish:
-Original Contributions: Peer-reviewed, investigations that represent new and significant contributions to the field. Recommended word count: up to 7500.
-Review Articles: Reviews of major areas or sub-areas in the field of clinical medical physics. These articles may be of any length and are peer reviewed.
-Technical Notes: These should be no longer than 3000 words, including key references.
-Letters to the Editor: Comments on papers published in JACMP or on any other matters of interest to clinical medical physics. These should not be more than 1250 (including the literature) and their publication is only based on the decision of the editor, who occasionally asks experts on the merit of the contents.
-Book Reviews: The editorial office solicits Book Reviews.
-Announcements of Forthcoming Meetings: The Editor may provide notice of forthcoming meetings, course offerings, and other events relevant to clinical medical physics.
-Parallel Opposed Editorial: We welcome topics relevant to clinical practice and medical physics profession. The contents can be controversial debate or opposed aspects of an issue. One author argues for the position and the other against. Each side of the debate contains an opening statement up to 800 words, followed by a rebuttal up to 500 words. Readers interested in participating in this series should contact the moderator with a proposed title and a short description of the topic