{"title":"Formaldehyde Levels and the Indoor Air Quality of an Anatomy Dissection Hall with Different Ventilation Setups.","authors":"Ganesh Handady, Anne Dsouza, Vanishri Nayak, Joseph Abraham","doi":"10.1177/11786302241301590","DOIUrl":null,"url":null,"abstract":"<p><p>During anatomy dissection, the release of formaldehyde (FA) from cadavers and embalming fluids can negatively affect the well-being of students and staff. The exposure of students, staff, and technicians to FA in the dissection hall is a concern. To address this issue, a study measured the FA and air quality (CO<sub>2</sub> and Total Volatile Organic Compounds- TVOC) with different ventilation setups: natural, fan-based, and air-conditioned. The FA levels and the indoor air quality at the breathing zone were estimated using an air conditioning (AC), fan-based, and naturally ventilated setup. The FA, CO<sub>2</sub>, and TVOC levels were calculated at the cadavers' head and toe ends, in the pathway, and between the dissection tables. The FA, CO<sub>2</sub>, and TVOC levels were higher near the cadaver and lower in the pathway and between the tables, regardless of the type of ventilation used. Fan-based ventilation had the lowest mean FA, CO<sub>2</sub>, and TVOC levels compared to AC and natural ventilation. However, there was no significant difference in these levels between the ventilation types, except for the toe-ends of the cadavers (<i>P</i> < .05), where the toe-end farther from the AC vents had higher levels. The study suggests that areas away from the source of ventilation in the anatomy dissection hall are at risk of having lower air quality. Therefore, in addition to selecting an appropriate ventilation system, placing the donor bodies near the source of ventilation would help optimize FA levels and improve indoor air quality for better working conditions suitable for students and staff.</p>","PeriodicalId":11827,"journal":{"name":"Environmental Health Insights","volume":"18 ","pages":"11786302241301590"},"PeriodicalIF":2.3000,"publicationDate":"2024-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11603455/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental Health Insights","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/11786302241301590","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
引用次数: 0

Abstract

During anatomy dissection, the release of formaldehyde (FA) from cadavers and embalming fluids can negatively affect the well-being of students and staff. The exposure of students, staff, and technicians to FA in the dissection hall is a concern. To address this issue, a study measured the FA and air quality (CO2 and Total Volatile Organic Compounds- TVOC) with different ventilation setups: natural, fan-based, and air-conditioned. The FA levels and the indoor air quality at the breathing zone were estimated using an air conditioning (AC), fan-based, and naturally ventilated setup. The FA, CO2, and TVOC levels were calculated at the cadavers' head and toe ends, in the pathway, and between the dissection tables. The FA, CO2, and TVOC levels were higher near the cadaver and lower in the pathway and between the tables, regardless of the type of ventilation used. Fan-based ventilation had the lowest mean FA, CO2, and TVOC levels compared to AC and natural ventilation. However, there was no significant difference in these levels between the ventilation types, except for the toe-ends of the cadavers (P < .05), where the toe-end farther from the AC vents had higher levels. The study suggests that areas away from the source of ventilation in the anatomy dissection hall are at risk of having lower air quality. Therefore, in addition to selecting an appropriate ventilation system, placing the donor bodies near the source of ventilation would help optimize FA levels and improve indoor air quality for better working conditions suitable for students and staff.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Environmental Health Insights
Environmental Health Insights PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH-
CiteScore
3.20
自引率
22.20%
发文量
97
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信