Wei Zheng , Rong Yan , Rui Ding , Guoliang Xu , Lei Mu , Yefan Zhu , Yuming Liu , Junlin Wan , Junling Chen
{"title":"Post-mortem analysis of material deposition and fuel retention on the plasma-facing materials after the 2021 campaign in EAST","authors":"Wei Zheng , Rong Yan , Rui Ding , Guoliang Xu , Lei Mu , Yefan Zhu , Yuming Liu , Junlin Wan , Junling Chen","doi":"10.1016/j.nme.2024.101828","DOIUrl":null,"url":null,"abstract":"<div><div>Plasma-wall interaction (PWI) is a critical concern in tokamaks because of its significant impact on the lifetimes of plasma-facing materials (PFMs), fuel retention, and plasma performance. In 2020, the Experimental Advanced Superconducting Tokamak (EAST) PFMs were upgraded to predominantly metallic walls. Following the 2021 experimental campaign, the deposition distribution and fuel retention on the surfaces of the PFMs along both the poloidal and toroidal directions were analyzed. The poloidal tests commenced at the high-field side (HFS), proceeded to the lower divertor, then to the low-field side (LFS), and finally to the upper divertor. The toroidal tests were performed at the midplane of the HFS, beginning from port A and ending at port P. The distributions of the deposits in the poloidal and toroidal directions were clearly asymmetrical. Mo and Fe particles sputtered from the first wall and inner stainless steel (SS) components were prone to deposition in the lower divertor region, as evidenced by the fact that the elemental content in the far-SOL region of the inner divertor exhibited Mo and Fe peaks, as did both the near- and far-SOL regions of the outer divertor. In addition, quick re-deposition of W and Fe was observed, as demonstrated by the fact that their contents near the erosion sources were higher than those farther away along the toroidal first wall on the HFS. This tendency was stronger for W than for Fe. Further analysis indicated that the deposits consisted of Li, C, O, W, Mo, Fe, Cu, and Ni. The Li and Fe contents were much higher than those of other metal impurities, with peak values of 8.17 μg/mm<sup>2</sup> and 7.78 μg/mm<sup>2</sup>, respectively. The Li content decreased along the HFS first wall from 8.17 μg/mm<sup>2</sup> at P-2 to 1.82 μg/mm<sup>2</sup> at P-22, and then increased to 2.72 μg/mm<sup>2</sup> at P-32 in the divertor, while the Fe content was higher around the top side and the midplane of the HFS. The deposited Li originated from routine wall conditioning and existed primarily in the form of Li<sub>2</sub>CO<sub>3</sub>. Additionally, other metal impurities deposited on the Li<sub>2</sub>CO<sub>3</sub> surfaces exhibited various irregular shapes, often appearing as aggregated and recrystallized small particles. Furthermore, significant deuterium (D) retention on the order of 10<sup>21</sup> atoms/m<sup>2</sup> was measured on all the analyzed SiC-coated graphite tiles on the HFS. The D content at location P-10 at the midplane was the highest along the poloidal direction of the HFS because it was directly facing the NBI beam.</div></div>","PeriodicalId":56004,"journal":{"name":"Nuclear Materials and Energy","volume":"41 ","pages":"Article 101828"},"PeriodicalIF":2.3000,"publicationDate":"2024-11-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Materials and Energy","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352179124002515","RegionNum":2,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Plasma-wall interaction (PWI) is a critical concern in tokamaks because of its significant impact on the lifetimes of plasma-facing materials (PFMs), fuel retention, and plasma performance. In 2020, the Experimental Advanced Superconducting Tokamak (EAST) PFMs were upgraded to predominantly metallic walls. Following the 2021 experimental campaign, the deposition distribution and fuel retention on the surfaces of the PFMs along both the poloidal and toroidal directions were analyzed. The poloidal tests commenced at the high-field side (HFS), proceeded to the lower divertor, then to the low-field side (LFS), and finally to the upper divertor. The toroidal tests were performed at the midplane of the HFS, beginning from port A and ending at port P. The distributions of the deposits in the poloidal and toroidal directions were clearly asymmetrical. Mo and Fe particles sputtered from the first wall and inner stainless steel (SS) components were prone to deposition in the lower divertor region, as evidenced by the fact that the elemental content in the far-SOL region of the inner divertor exhibited Mo and Fe peaks, as did both the near- and far-SOL regions of the outer divertor. In addition, quick re-deposition of W and Fe was observed, as demonstrated by the fact that their contents near the erosion sources were higher than those farther away along the toroidal first wall on the HFS. This tendency was stronger for W than for Fe. Further analysis indicated that the deposits consisted of Li, C, O, W, Mo, Fe, Cu, and Ni. The Li and Fe contents were much higher than those of other metal impurities, with peak values of 8.17 μg/mm2 and 7.78 μg/mm2, respectively. The Li content decreased along the HFS first wall from 8.17 μg/mm2 at P-2 to 1.82 μg/mm2 at P-22, and then increased to 2.72 μg/mm2 at P-32 in the divertor, while the Fe content was higher around the top side and the midplane of the HFS. The deposited Li originated from routine wall conditioning and existed primarily in the form of Li2CO3. Additionally, other metal impurities deposited on the Li2CO3 surfaces exhibited various irregular shapes, often appearing as aggregated and recrystallized small particles. Furthermore, significant deuterium (D) retention on the order of 1021 atoms/m2 was measured on all the analyzed SiC-coated graphite tiles on the HFS. The D content at location P-10 at the midplane was the highest along the poloidal direction of the HFS because it was directly facing the NBI beam.
期刊介绍:
The open-access journal Nuclear Materials and Energy is devoted to the growing field of research for material application in the production of nuclear energy. Nuclear Materials and Energy publishes original research articles of up to 6 pages in length.