High flow nasal cannula and low level continuous positive airway pressure have different physiological effects during de novo acute hypoxemic respiratory failure.

IF 5.7 1区 医学 Q1 CRITICAL CARE MEDICINE
Samuel Tuffet, Mohamed Ahmed Boujelben, Anne-Fleur Haudebourg, Tommaso Maraffi, François Perier, Pascale Labedade, Elsa Moncomble, Ségolène Gendreau, Matthieu Lacheny, Emmanuel Vivier, Armand Mekontso-Dessap, Guillaume Carteaux
{"title":"High flow nasal cannula and low level continuous positive airway pressure have different physiological effects during de novo acute hypoxemic respiratory failure.","authors":"Samuel Tuffet, Mohamed Ahmed Boujelben, Anne-Fleur Haudebourg, Tommaso Maraffi, François Perier, Pascale Labedade, Elsa Moncomble, Ségolène Gendreau, Matthieu Lacheny, Emmanuel Vivier, Armand Mekontso-Dessap, Guillaume Carteaux","doi":"10.1186/s13613-024-01408-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Large tidal volumes during de novo acute hypoxemic respiratory failure (AHRF) may promote patient self-inflicted lung injury. Tidal volume assessment under high flow nasal cannula (HFNC) is not routinely feasible at the bedside. Our objective was to determine whether tidal volume during low-level continuous positive airway pressure (CPAP) could predict tidal volume during HFNC and to compare the physiological effects of HFNC and low-level CPAP.</p><p><strong>Methods: </strong>Prospective, single-center study including 29 de novo AHRF patients treated with HFNC (50 to 60 L.min<sup>- 1</sup>). Patients were monitored using electrical impedance tomography during HFNC then CPAP at 4 cmH<sub>2</sub>O. Tidal volume during HFNC was calculated based on tidal impedance variation. The ability of tidal volume under low-level CPAP to predict tidal volume under HFNC was explored using Bland-Altman analysis. CPAP and HFNC were compared in terms of tidal volume, minute ventilation, respiratory comfort, dyspnea, oxygenation, ventilation distribution, end-expiratory lung volume, thoraco-abdominal asynchrony and recruitment.</p><p><strong>Results: </strong>Under HFNC, patients had a tidal volume of 6.6 (5.9-8.7) mL.kg<sup>- 1</sup> PBW. 20 (69%) patients exhibited a tidal volume between 4 and 8 mL.kg<sup>- 1</sup> PBW, while in 5 (17%) patients it exceeded 9 mL.kg<sup>- 1</sup> PBW. Tidal volume under CPAP was higher (9.4 (8.3-11) mL.kg<sup>- 1</sup> PBW, p < 0.001). Tidal volumes under CPAP and under HFNC were modestly correlated (Spearman r = 0.50, p = 0.005). Bland-Altman analysis showed a bias of 2.4 mL.kg<sup>- 1</sup>, with limits of agreement ranging from - 1.1 mL.kg<sup>- 1</sup>to 5.9 mL.kg<sup>- 1</sup>. Nevertheless, a larger (> 11.5 mL.kg<sup>- 1</sup> PBW ) tidal volume under low-level CPAP predicted a larger (> 9 mL.kg<sup>- 1</sup> PBW ) tidal volume under HFNC with 80% sensitivity and 96% specificity. Low-level CPAP was associated with increased minute ventilation, end-expiratory lung volume, and oxygenation as compared to HFNC. It decreased signs of respiratory distress in the most severe patients but was associated with lower comfort compared to HFNC.</p><p><strong>Conclusion: </strong>Among ICU patients with de novo AHRF, tidal volume under HFNC was mostly protective. Tidal volume during CPAP at 4 cmH<sub>2</sub>O did not predict tidal volume during HFNC. Such low-level CPAP was associated with increased tidal volume, minute ventilation, end-expiratory volume, and oxygenation.</p><p><strong>Trial registration: </strong>ClinicalTrials.gov ID NCT03919331. Registration date: 2019-03-26.</p>","PeriodicalId":7966,"journal":{"name":"Annals of Intensive Care","volume":"14 1","pages":"171"},"PeriodicalIF":5.7000,"publicationDate":"2024-11-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Intensive Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13613-024-01408-w","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Large tidal volumes during de novo acute hypoxemic respiratory failure (AHRF) may promote patient self-inflicted lung injury. Tidal volume assessment under high flow nasal cannula (HFNC) is not routinely feasible at the bedside. Our objective was to determine whether tidal volume during low-level continuous positive airway pressure (CPAP) could predict tidal volume during HFNC and to compare the physiological effects of HFNC and low-level CPAP.

Methods: Prospective, single-center study including 29 de novo AHRF patients treated with HFNC (50 to 60 L.min- 1). Patients were monitored using electrical impedance tomography during HFNC then CPAP at 4 cmH2O. Tidal volume during HFNC was calculated based on tidal impedance variation. The ability of tidal volume under low-level CPAP to predict tidal volume under HFNC was explored using Bland-Altman analysis. CPAP and HFNC were compared in terms of tidal volume, minute ventilation, respiratory comfort, dyspnea, oxygenation, ventilation distribution, end-expiratory lung volume, thoraco-abdominal asynchrony and recruitment.

Results: Under HFNC, patients had a tidal volume of 6.6 (5.9-8.7) mL.kg- 1 PBW. 20 (69%) patients exhibited a tidal volume between 4 and 8 mL.kg- 1 PBW, while in 5 (17%) patients it exceeded 9 mL.kg- 1 PBW. Tidal volume under CPAP was higher (9.4 (8.3-11) mL.kg- 1 PBW, p < 0.001). Tidal volumes under CPAP and under HFNC were modestly correlated (Spearman r = 0.50, p = 0.005). Bland-Altman analysis showed a bias of 2.4 mL.kg- 1, with limits of agreement ranging from - 1.1 mL.kg- 1to 5.9 mL.kg- 1. Nevertheless, a larger (> 11.5 mL.kg- 1 PBW ) tidal volume under low-level CPAP predicted a larger (> 9 mL.kg- 1 PBW ) tidal volume under HFNC with 80% sensitivity and 96% specificity. Low-level CPAP was associated with increased minute ventilation, end-expiratory lung volume, and oxygenation as compared to HFNC. It decreased signs of respiratory distress in the most severe patients but was associated with lower comfort compared to HFNC.

Conclusion: Among ICU patients with de novo AHRF, tidal volume under HFNC was mostly protective. Tidal volume during CPAP at 4 cmH2O did not predict tidal volume during HFNC. Such low-level CPAP was associated with increased tidal volume, minute ventilation, end-expiratory volume, and oxygenation.

Trial registration: ClinicalTrials.gov ID NCT03919331. Registration date: 2019-03-26.

在新发急性低氧血症呼吸衰竭期间,高流量鼻插管和低水平持续气道正压具有不同的生理效应。
背景:新发急性低氧血症呼吸衰竭(AHRF)期间的大潮气量可能会导致患者自我造成肺损伤。高流量鼻插管(HFNC)下的潮气量评估无法在床旁常规进行。我们的目的是确定低水平持续气道正压(CPAP)时的潮气量能否预测高流量鼻插管时的潮气量,并比较高流量鼻插管和低水平 CPAP 的生理效应:前瞻性单中心研究,包括 29 名接受 HFNC(50 至 60 升/分钟-1)治疗的新发 AHRF 患者。患者在使用 HFNC 期间接受电阻抗断层扫描监测,然后在 4 cmH2O 的水平使用 CPAP。根据潮气阻抗变化计算 HFNC 期间的潮气量。使用 Bland-Altman 分析法探讨了低水平 CPAP 下的潮气量预测 HFNC 下潮气量的能力。从潮气量、分钟通气量、呼吸舒适度、呼吸困难、氧合作用、通气分布、呼气末肺容量、胸腹不同步和募集等方面对 CPAP 和 HFNC 进行了比较:在 HFNC 条件下,患者的潮气量为 6.6 (5.9-8.7) mL.kg- 1 PBW。20(69%)名患者的潮气量在 4 至 8 mL.kg- 1 PBW 之间,5(17%)名患者的潮气量超过 9 mL.kg- 1 PBW。CPAP 条件下的潮气量更高(9.4 (8.3-11) mL.kg- 1 PBW,p - 1,一致性范围为 - 1.1 mL.kg- 1 至 5.9 mL.kg- 1。尽管如此,在低水平 CPAP 下较大的潮气量(> 11.5 mL.kg- 1 PBW)预示着在 HFNC 下较大的潮气量(> 9 mL.kg- 1 PBW),灵敏度为 80%,特异度为 96%。与 HFNC 相比,低水平 CPAP 可增加分钟通气量、呼气末肺活量和氧饱和度。低水平 CPAP 可减少最严重患者的呼吸窘迫症状,但与 HFNC 相比,舒适度较低:结论:在 ICU 新发 AHRF 患者中,HFNC 下的潮气量大多具有保护作用。4 cmH2O CPAP 时的潮气量不能预测 HFNC 时的潮气量。这种低水平的 CPAP 与潮气量、分钟通气量、呼气末容积和氧饱和度的增加有关:临床试验注册:ClinicalTrials.gov ID NCT03919331。注册日期:2019-03-26。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Annals of Intensive Care
Annals of Intensive Care CRITICAL CARE MEDICINE-
CiteScore
14.20
自引率
3.70%
发文量
107
审稿时长
13 weeks
期刊介绍: Annals of Intensive Care is an online peer-reviewed journal that publishes high-quality review articles and original research papers in the field of intensive care medicine. It targets critical care providers including attending physicians, fellows, residents, nurses, and physiotherapists, who aim to enhance their knowledge and provide optimal care for their patients. The journal's articles are included in various prestigious databases such as CAS, Current contents, DOAJ, Embase, Journal Citation Reports/Science Edition, OCLC, PubMed, PubMed Central, Science Citation Index Expanded, SCOPUS, and Summon by Serial Solutions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信