Determination of urine volume and glomerular filtration rate using d-serine and d-asparagine.

IF 4.8 2区 医学 Q1 TRANSPLANTATION
Ryo Tanaka, Shinsuke Sakai, Ayumu Taniguchi, Masataka Kawamura, Yoko Higa-Maegawa, Soichi Matsumura, Shota Fukae, Shigeaki Nakazawa, Shihoko Kimura-Ohba, Masaru Horio, Shiro Takahara, Ryoichi Imamura, Norio Nonomura, Masayuki Mizui, Yoshitaka Isaka, Yoichi Kakuta, Tomonori Kimura
{"title":"Determination of urine volume and glomerular filtration rate using d-serine and d-asparagine.","authors":"Ryo Tanaka, Shinsuke Sakai, Ayumu Taniguchi, Masataka Kawamura, Yoko Higa-Maegawa, Soichi Matsumura, Shota Fukae, Shigeaki Nakazawa, Shihoko Kimura-Ohba, Masaru Horio, Shiro Takahara, Ryoichi Imamura, Norio Nonomura, Masayuki Mizui, Yoshitaka Isaka, Yoichi Kakuta, Tomonori Kimura","doi":"10.1093/ndt/gfae279","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and hypothesis: </strong>Measurement of glomerular filtration rate (GFR) is subject to inaccurate urine collection. Clearances of d-serine and d-asparagine, rare enantiomers of amino acids, are the measures of GFR since they are almost free of tubular secretion and reabsorption. We hypothesize that d-serine and d-asparagine can accurately determine urine volume and GFR.</p><p><strong>Methods: </strong>This cross-sectional observational study included 209 living kidney transplant donors and recipients for whom GFR was measured using the clearance of inulin. Assuming that urine excretions of d-serine and d-asparagine are constant and using urine levels of d-serine and d-asparagine from each urine collection, an equation for estimated urine volume (eUV) was established. Based on the eUV, the abnormal urine volume was replaced with an estimate with which the GFR was re-evaluated.</p><p><strong>Result: </strong>Clearances of d-serine and d-asparagine were minor in proportional biases when compared with that of creatinine. Using 627 urine collection, the equation for eUV (mL/min) was established as 21.88/urine d-Ser (0.40 + 0.20 × log10(urine d-Asn)). Using eUV, we identified 20 instances where urine collection volumes varied significantly from the estimated values. After replacement with eUV, measured GFR (mGFR) was corrected to adjusted mGFR, which was within approximately 20 mL/min/1.73m2 of the mGFR.</p><p><strong>Conclusion: </strong>d-Serine and d-asparagine are nearly completely excreted in urine after glomerular filtration, enabling the estimation of urine volume and correct mGFR. Besides reflecting GFR, d-serine and d-asparagine can be used to estimate urine volume. By applying the eUV method, mGFR determined using clearance methods becomes more accurate.</p>","PeriodicalId":19078,"journal":{"name":"Nephrology Dialysis Transplantation","volume":" ","pages":""},"PeriodicalIF":4.8000,"publicationDate":"2024-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nephrology Dialysis Transplantation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/ndt/gfae279","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"TRANSPLANTATION","Score":null,"Total":0}
引用次数: 0

Abstract

Background and hypothesis: Measurement of glomerular filtration rate (GFR) is subject to inaccurate urine collection. Clearances of d-serine and d-asparagine, rare enantiomers of amino acids, are the measures of GFR since they are almost free of tubular secretion and reabsorption. We hypothesize that d-serine and d-asparagine can accurately determine urine volume and GFR.

Methods: This cross-sectional observational study included 209 living kidney transplant donors and recipients for whom GFR was measured using the clearance of inulin. Assuming that urine excretions of d-serine and d-asparagine are constant and using urine levels of d-serine and d-asparagine from each urine collection, an equation for estimated urine volume (eUV) was established. Based on the eUV, the abnormal urine volume was replaced with an estimate with which the GFR was re-evaluated.

Result: Clearances of d-serine and d-asparagine were minor in proportional biases when compared with that of creatinine. Using 627 urine collection, the equation for eUV (mL/min) was established as 21.88/urine d-Ser (0.40 + 0.20 × log10(urine d-Asn)). Using eUV, we identified 20 instances where urine collection volumes varied significantly from the estimated values. After replacement with eUV, measured GFR (mGFR) was corrected to adjusted mGFR, which was within approximately 20 mL/min/1.73m2 of the mGFR.

Conclusion: d-Serine and d-asparagine are nearly completely excreted in urine after glomerular filtration, enabling the estimation of urine volume and correct mGFR. Besides reflecting GFR, d-serine and d-asparagine can be used to estimate urine volume. By applying the eUV method, mGFR determined using clearance methods becomes more accurate.

使用 d-丝氨酸和 d-天冬酰胺测定尿量和肾小球滤过率。
背景和假设:肾小球滤过率(GFR)的测量受尿液收集不准确的影响。d-丝氨酸和d-天冬酰胺是氨基酸的稀有对映体,由于它们几乎不受肾小管分泌和重吸收的影响,因此它们的清除率是衡量肾小球滤过率的标准。我们假设 d-丝氨酸和 d-天冬酰胺能准确测定尿量和 GFR:这项横断面观察性研究包括 209 名活体肾移植供体和受体,他们的 GFR 都是通过菊粉的清除率来测量的。假设尿液中 d-丝氨酸和 d-天冬酰胺的排泄量是恒定的,并利用每次尿液采集中 d-丝氨酸和 d-天冬酰胺的尿液水平,建立了估算尿量(eUV)的方程。根据 eUV,用估计值代替异常尿量,并据此重新评估 GFR:结果:与肌酐相比,d-丝氨酸和 d-天冬酰胺的清除率在比例偏差上较小。通过收集 627 次尿液,得出 eUV(毫升/分钟)的计算公式为:21.88/尿液 d-Ser (0.40 + 0.20 × log10(尿液 d-Asn))。通过使用 eUV,我们确定了 20 个尿液收集量与估计值有显著差异的实例。结论:d-丝氨酸和 d-天冬酰胺经肾小球滤过后几乎完全从尿液中排出,因此可以估算尿量并正确计算 mGFR。除了反映肾小球滤过率,d-丝氨酸和 d-天冬酰胺还可用于估算尿量。应用 eUV 方法后,使用清除率方法测定的 mGFR 将变得更加准确。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Nephrology Dialysis Transplantation
Nephrology Dialysis Transplantation 医学-泌尿学与肾脏学
CiteScore
10.10
自引率
4.90%
发文量
1431
审稿时长
1.7 months
期刊介绍: Nephrology Dialysis Transplantation (ndt) is the leading nephrology journal in Europe and renowned worldwide, devoted to original clinical and laboratory research in nephrology, dialysis and transplantation. ndt is an official journal of the [ERA-EDTA](http://www.era-edta.org/) (European Renal Association-European Dialysis and Transplant Association). Published monthly, the journal provides an essential resource for researchers and clinicians throughout the world. All research articles in this journal have undergone peer review. Print ISSN: 0931-0509.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信