{"title":"Evaluation of the applicability of urine lateral flow immunochromatography tests for the detection of cocaine in plasma samples.","authors":"Isabella Almeida Millan de Souza, Bruno Pereira Dos Santos, Sabrina Nunes do Nascimento, Letícia Birk, Viviane Cristina Sebben, Sarah Eller, Tiago Franco de Oliveira","doi":"10.1016/j.clinbiochem.2024.110854","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Qualitative analysis of cocaine in urine is a common practice in emergency settings. However, positive results from urine screening tests do not necessarily indicate recent exposure. In this context, plasma is considered a more appropriate option due to its shorter detection window and better correlation with symptomatology. Therefore, the availability of rapid tests for this biological matrix is extremely relevant in the clinical and emergency context.</p><p><strong>Methods: </strong>A lateral flow immunochromatography test designed for analyzing cocaine in urine was evaluated for use with plasma samples. A total of 412 samples from suspected cases of intoxication were processed and tested. Concurrently, the samples were analyzed for cocaine and its metabolites, benzoylecgonine and ecgonine methyl ester, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Reliability parameters, including sensitivity, specificity, positive predictive value, negative predictive value, and efficiency, were calculated considering different cutoff values.</p><p><strong>Results: </strong>Approximately 8.3 % of the samples tested positive in the immunoassay, while 10.2 % had a concentration greater than 5 ng/mL for at least one analyte in the LC-MS/MS analysis. Using benzoylecgonine as the target analyte with a cutoff of 40 ng/mL yielded the best reliability results, with 96.3 % sensitivity and 97.9 % specificity. Cocaine did not show satisfactory results, whereas ecgonine methyl ester, despite having 92.9 % sensitivity and 94.7 % specificity at its best cutoff (20 ng/mL), had a positive predictive value of only 38.2 %.</p><p><strong>Conclusions: </strong>The study evaluated the suitability of using rapid urine tests for cocaine detection in plasma, offering a simple and quick drug screening method that is particularly useful in toxicological emergencies.</p>","PeriodicalId":10172,"journal":{"name":"Clinical biochemistry","volume":" ","pages":"110854"},"PeriodicalIF":2.5000,"publicationDate":"2024-11-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical biochemistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.clinbiochem.2024.110854","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Qualitative analysis of cocaine in urine is a common practice in emergency settings. However, positive results from urine screening tests do not necessarily indicate recent exposure. In this context, plasma is considered a more appropriate option due to its shorter detection window and better correlation with symptomatology. Therefore, the availability of rapid tests for this biological matrix is extremely relevant in the clinical and emergency context.

Methods: A lateral flow immunochromatography test designed for analyzing cocaine in urine was evaluated for use with plasma samples. A total of 412 samples from suspected cases of intoxication were processed and tested. Concurrently, the samples were analyzed for cocaine and its metabolites, benzoylecgonine and ecgonine methyl ester, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Reliability parameters, including sensitivity, specificity, positive predictive value, negative predictive value, and efficiency, were calculated considering different cutoff values.

Results: Approximately 8.3 % of the samples tested positive in the immunoassay, while 10.2 % had a concentration greater than 5 ng/mL for at least one analyte in the LC-MS/MS analysis. Using benzoylecgonine as the target analyte with a cutoff of 40 ng/mL yielded the best reliability results, with 96.3 % sensitivity and 97.9 % specificity. Cocaine did not show satisfactory results, whereas ecgonine methyl ester, despite having 92.9 % sensitivity and 94.7 % specificity at its best cutoff (20 ng/mL), had a positive predictive value of only 38.2 %.

Conclusions: The study evaluated the suitability of using rapid urine tests for cocaine detection in plasma, offering a simple and quick drug screening method that is particularly useful in toxicological emergencies.

评估尿液侧流免疫层析检测法检测血浆样本中可卡因的适用性。
导言:对尿液中的可卡因进行定性分析是急诊环境中的常见做法。然而,尿液筛查试验的阳性结果并不一定表明最近接触过可卡因。在这种情况下,血浆被认为是更合适的选择,因为它的检测时间更短,与症状的相关性更好。因此,提供这种生物基质的快速检测方法对临床和急救工作极为重要:方法:评估了用于分析尿液中可卡因的侧流免疫层析检测法在血浆样本中的应用。共处理和检测了 412 份疑似中毒病例的样本。同时,利用液相色谱-串联质谱法(LC-MS/MS)对样本中的可卡因及其代谢物苯甲酰可待因和可待因甲酯进行了分析。根据不同的临界值计算了灵敏度、特异性、阳性预测值、阴性预测值和效率等可靠性参数:约 8.3% 的样本在免疫测定中呈阳性,而 10.2% 的样本在 LC-MS/MS 分析中至少有一种分析物的浓度超过 5 纳克/毫升。以苯甲酰可待因为目标分析物,以 40 纳克/毫升为临界值,结果可靠性最佳,灵敏度为 96.3%,特异性为 97.9%。可卡因的结果并不令人满意,而蜕皮激素甲酯尽管在最佳临界值(20 纳克/毫升)下具有 92.9 % 的灵敏度和 94.7 % 的特异性,但其阳性预测值仅为 38.2 %:该研究评估了使用快速尿检检测血浆中可卡因的适用性,提供了一种简单、快速的药物筛查方法,尤其适用于毒理学紧急情况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Clinical biochemistry
Clinical biochemistry 医学-医学实验技术
CiteScore
5.10
自引率
0.00%
发文量
151
审稿时长
25 days
期刊介绍: Clinical Biochemistry publishes articles relating to clinical chemistry, molecular biology and genetics, therapeutic drug monitoring and toxicology, laboratory immunology and laboratory medicine in general, with the focus on analytical and clinical investigation of laboratory tests in humans used for diagnosis, prognosis, treatment and therapy, and monitoring of disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信