Aditi Bunker, Karin Lundgren Kownacki, Sudipa Sarker, Rahmatul Bari, Malabika Sarker, Jonathan J. Buonocore, Pascal Geldsetzer, Johan Revstedt, Till Bärnighausen
{"title":"Evaluating the effectiveness of the ‘eco-cooler’ for passive home cooling","authors":"Aditi Bunker, Karin Lundgren Kownacki, Sudipa Sarker, Rahmatul Bari, Malabika Sarker, Jonathan J. Buonocore, Pascal Geldsetzer, Johan Revstedt, Till Bärnighausen","doi":"10.1038/s44168-024-00165-7","DOIUrl":null,"url":null,"abstract":"Constructed with used plastic bottles, the eco-cooler has been widely adopted in resource-poor communities in Bangladesh and other countries. We tested the eco-cooler under controlled conditions using a scientific wind tunnel in a climatic chamber. In our tests, we used seven eco-cooler designs in 27 climate conditions typical of Bangladesh (temperatures of 40 °C, 35 °C, and 30 °C; humidity levels of 70%, 60%, and 40%; and wind speeds of 4.0 m s−1, 2.0 m s−1, and 0.2 m s−1) in 92 experiments (N = 7686 measurements in 87 short experiments and N = 23,428 measurements in five long experiments). We found no significant temperature reductions with eco-cooler use, except at low wind speeds, where temperature reduced by up to 0.2 °C. In theoretical calculations extending our empirical findings, the greatest temperature drop was 0.85 °C at 4.0 m s−1 with a 40 °C static air inflow temperature. However, this temperature drop did not extend beyond the nozzles of the bottles in the eco-cooler. The eco-cooler did not work effectively as an indoor air cooler.","PeriodicalId":186004,"journal":{"name":"npj Climate Action","volume":" ","pages":"1-9"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11531403/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"npj Climate Action","FirstCategoryId":"1085","ListUrlMain":"https://www.nature.com/articles/s44168-024-00165-7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Constructed with used plastic bottles, the eco-cooler has been widely adopted in resource-poor communities in Bangladesh and other countries. We tested the eco-cooler under controlled conditions using a scientific wind tunnel in a climatic chamber. In our tests, we used seven eco-cooler designs in 27 climate conditions typical of Bangladesh (temperatures of 40 °C, 35 °C, and 30 °C; humidity levels of 70%, 60%, and 40%; and wind speeds of 4.0 m s−1, 2.0 m s−1, and 0.2 m s−1) in 92 experiments (N = 7686 measurements in 87 short experiments and N = 23,428 measurements in five long experiments). We found no significant temperature reductions with eco-cooler use, except at low wind speeds, where temperature reduced by up to 0.2 °C. In theoretical calculations extending our empirical findings, the greatest temperature drop was 0.85 °C at 4.0 m s−1 with a 40 °C static air inflow temperature. However, this temperature drop did not extend beyond the nozzles of the bottles in the eco-cooler. The eco-cooler did not work effectively as an indoor air cooler.