{"title":"Bidirectional dynamic frame prediction network for total-body [<sup>68</sup>Ga]Ga-PSMA-11 and [<sup>68</sup>Ga]Ga-FAPI-04 PET images.","authors":"Qianyi Yang, Wenbo Li, Zhenxing Huang, Zixiang Chen, Wenjie Zhao, Yunlong Gao, Xinlan Yang, Yongfeng Yang, Hairong Zheng, Dong Liang, Jianjun Liu, Ruohua Chen, Zhanli Hu","doi":"10.1186/s40658-024-00698-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Total-body dynamic positron emission tomography (PET) imaging with total-body coverage and ultrahigh sensitivity has played an important role in accurate tracer kinetic analyses in physiology, biochemistry, and pharmacology. However, dynamic PET scans typically entail prolonged durations ([Formula: see text]60 minutes), potentially causing patient discomfort and resulting in artifacts in the final images. Therefore, we propose a dynamic frame prediction method for total-body PET imaging via deep learning technology to reduce the required scanning time.</p><p><strong>Methods: </strong>On the basis of total-body dynamic PET data acquired from 13 subjects who received [<sup>68</sup>Ga]Ga-FAPI-04 (<sup>68</sup>Ga-FAPI) and 24 subjects who received [<sup>68</sup>Ga]Ga-PSMA-11 (<sup>68</sup>Ga-PSMA), we propose a bidirectional dynamic frame prediction network that uses the initial and final 10 min of PET imaging data (frames 1-6 and frames 25-30, respectively) as inputs. The peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM) were employed as evaluation metrics for an image quality assessment. Moreover, we calculated parametric images (<sup>68</sup>Ga-FAPI: [Formula: see text], <sup>68</sup>Ga-PSMA: [Formula: see text]) based on the supplemented sequence data to observe the quantitative accuracy of our approach. Regions of interest (ROIs) and statistical analyses were utilized to evaluate the performance of the model.</p><p><strong>Results: </strong>Both the visual and quantitative results illustrate the effectiveness of our approach. The generated dynamic PET images yielded PSNRs of 36.056 ± 0.709 dB for the <sup>68</sup>Ga-PSMA group and 33.779 ± 0.760 dB for the <sup>68</sup>Ga-FAPI group. Additionally, the SSIM reached 0.935 ± 0.006 for the <sup>68</sup>Ga-FAPI group and 0.922 ± 0.009 for the <sup>68</sup>Ga-PSMA group. By conducting a quantitative analysis on the parametric images, we obtained PSNRs of 36.155 ± 4.813 dB (<sup>68</sup>Ga-PSMA, [Formula: see text]) and 43.150 ± 4.102 dB (<sup>68</sup>Ga-FAPI, [Formula: see text]). The obtained SSIM values were 0.932 ± 0.041 (<sup>68</sup>Ga-PSMA) and 0.980 ± 0.011 (<sup>68</sup>Ga-FAPI). The ROI analysis conducted on our generated dynamic PET sequences also revealed that our method can accurately predict temporal voxel intensity changes, maintaining overall visual consistency with the ground truth.</p><p><strong>Conclusion: </strong>In this work, we propose a bidirectional dynamic frame prediction network for total-body <sup>68</sup>Ga-PSMA and <sup>68</sup>Ga-FAPI PET imaging with a reduced scan duration. Visual and quantitative analyses demonstrated that our approach performed well when it was used to predict one-hour dynamic PET images. https://github.com/OPMZZZ/BDF-NET .</p>","PeriodicalId":11559,"journal":{"name":"EJNMMI Physics","volume":"11 1","pages":"92"},"PeriodicalIF":3.0000,"publicationDate":"2024-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11532329/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40658-024-00698-0","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Total-body dynamic positron emission tomography (PET) imaging with total-body coverage and ultrahigh sensitivity has played an important role in accurate tracer kinetic analyses in physiology, biochemistry, and pharmacology. However, dynamic PET scans typically entail prolonged durations ([Formula: see text]60 minutes), potentially causing patient discomfort and resulting in artifacts in the final images. Therefore, we propose a dynamic frame prediction method for total-body PET imaging via deep learning technology to reduce the required scanning time.
Methods: On the basis of total-body dynamic PET data acquired from 13 subjects who received [68Ga]Ga-FAPI-04 (68Ga-FAPI) and 24 subjects who received [68Ga]Ga-PSMA-11 (68Ga-PSMA), we propose a bidirectional dynamic frame prediction network that uses the initial and final 10 min of PET imaging data (frames 1-6 and frames 25-30, respectively) as inputs. The peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM) were employed as evaluation metrics for an image quality assessment. Moreover, we calculated parametric images (68Ga-FAPI: [Formula: see text], 68Ga-PSMA: [Formula: see text]) based on the supplemented sequence data to observe the quantitative accuracy of our approach. Regions of interest (ROIs) and statistical analyses were utilized to evaluate the performance of the model.
Results: Both the visual and quantitative results illustrate the effectiveness of our approach. The generated dynamic PET images yielded PSNRs of 36.056 ± 0.709 dB for the 68Ga-PSMA group and 33.779 ± 0.760 dB for the 68Ga-FAPI group. Additionally, the SSIM reached 0.935 ± 0.006 for the 68Ga-FAPI group and 0.922 ± 0.009 for the 68Ga-PSMA group. By conducting a quantitative analysis on the parametric images, we obtained PSNRs of 36.155 ± 4.813 dB (68Ga-PSMA, [Formula: see text]) and 43.150 ± 4.102 dB (68Ga-FAPI, [Formula: see text]). The obtained SSIM values were 0.932 ± 0.041 (68Ga-PSMA) and 0.980 ± 0.011 (68Ga-FAPI). The ROI analysis conducted on our generated dynamic PET sequences also revealed that our method can accurately predict temporal voxel intensity changes, maintaining overall visual consistency with the ground truth.
Conclusion: In this work, we propose a bidirectional dynamic frame prediction network for total-body 68Ga-PSMA and 68Ga-FAPI PET imaging with a reduced scan duration. Visual and quantitative analyses demonstrated that our approach performed well when it was used to predict one-hour dynamic PET images. https://github.com/OPMZZZ/BDF-NET .
期刊介绍:
EJNMMI Physics is an international platform for scientists, users and adopters of nuclear medicine with a particular interest in physics matters. As a companion journal to the European Journal of Nuclear Medicine and Molecular Imaging, this journal has a multi-disciplinary approach and welcomes original materials and studies with a focus on applied physics and mathematics as well as imaging systems engineering and prototyping in nuclear medicine. This includes physics-driven approaches or algorithms supported by physics that foster early clinical adoption of nuclear medicine imaging and therapy.