Floris C.J. Reinders , Mark H.F. Savenije , Mischa de Ridder , Matteo Maspero , Patricia A.H. Doornaert , Chris H.J. Terhaard , Cornelis P.J. Raaijmakers , Kaveh Zakeri , Nancy Y. Lee , Eric Aliotta , Aneesh Rangnekar , Harini Veeraraghavan , Marielle E.P. Philippens
{"title":"Automatic segmentation for magnetic resonance imaging guided individual elective lymph node irradiation in head and neck cancer patients","authors":"Floris C.J. Reinders , Mark H.F. Savenije , Mischa de Ridder , Matteo Maspero , Patricia A.H. Doornaert , Chris H.J. Terhaard , Cornelis P.J. Raaijmakers , Kaveh Zakeri , Nancy Y. Lee , Eric Aliotta , Aneesh Rangnekar , Harini Veeraraghavan , Marielle E.P. Philippens","doi":"10.1016/j.phro.2024.100655","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and purpose</h3><div>In head and neck squamous cell carcinoma (HNSCC) patients, the radiation dose to nearby organs at risk can be reduced by restricting elective neck irradiation from lymph node levels to individual lymph nodes. However, manual delineation of every individual lymph node is time-consuming and error prone. Therefore, automatic magnetic resonance imaging (MRI) segmentation of individual lymph nodes was developed and tested using a convolutional neural network (CNN).</div></div><div><h3>Materials and methods</h3><div>In 50 HNSCC patients (UMC-Utrecht), individual lymph nodes located in lymph node levels Ib-II-III-IV-V were manually segmented on MRI by consensus of two experts, obtaining ground truth segmentations. A 3D CNN (nnU-Net) was trained on 40 patients and tested on 10. Evaluation metrics were Dice Similarity Coefficient (DSC), recall, precision, and F1-score. The segmentations of the CNN was compared to segmentations of two observers. Transfer learning was used with 20 additional patients to re-train and test the CNN in another medical center.</div></div><div><h3>Results</h3><div>nnU-Net produced automatic segmentations of elective lymph nodes with median DSC: 0.72, recall: 0.76, precision: 0.78, and F1-score: 0.78. The CNN had higher recall compared to both observers (p = 0.002). No difference in evaluation scores of the networks in both medical centers was found after re-training with 5 or 10 patients.</div></div><div><h3>Conclusion</h3><div>nnU-Net was able to automatically segment individual lymph nodes on MRI. The detection rate of lymph nodes using nnU-Net was higher than manual segmentations. Re-training nnU-Net was required to successfully transfer the network to the other medical center.</div></div>","PeriodicalId":36850,"journal":{"name":"Physics and Imaging in Radiation Oncology","volume":"32 ","pages":"Article 100655"},"PeriodicalIF":3.4000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics and Imaging in Radiation Oncology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2405631624001258","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background and purpose
In head and neck squamous cell carcinoma (HNSCC) patients, the radiation dose to nearby organs at risk can be reduced by restricting elective neck irradiation from lymph node levels to individual lymph nodes. However, manual delineation of every individual lymph node is time-consuming and error prone. Therefore, automatic magnetic resonance imaging (MRI) segmentation of individual lymph nodes was developed and tested using a convolutional neural network (CNN).
Materials and methods
In 50 HNSCC patients (UMC-Utrecht), individual lymph nodes located in lymph node levels Ib-II-III-IV-V were manually segmented on MRI by consensus of two experts, obtaining ground truth segmentations. A 3D CNN (nnU-Net) was trained on 40 patients and tested on 10. Evaluation metrics were Dice Similarity Coefficient (DSC), recall, precision, and F1-score. The segmentations of the CNN was compared to segmentations of two observers. Transfer learning was used with 20 additional patients to re-train and test the CNN in another medical center.
Results
nnU-Net produced automatic segmentations of elective lymph nodes with median DSC: 0.72, recall: 0.76, precision: 0.78, and F1-score: 0.78. The CNN had higher recall compared to both observers (p = 0.002). No difference in evaluation scores of the networks in both medical centers was found after re-training with 5 or 10 patients.
Conclusion
nnU-Net was able to automatically segment individual lymph nodes on MRI. The detection rate of lymph nodes using nnU-Net was higher than manual segmentations. Re-training nnU-Net was required to successfully transfer the network to the other medical center.