{"title":"Findings of energy spectrum CT in anterior talofibular ligament injury of ankle joint","authors":"Huize Qin","doi":"10.1016/j.jmir.2024.101502","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>To evaluate the diagnostic value of energy spectrum CT in structural injury of anterior talofibular ligament using MRI as reference standard.</div></div><div><h3>Methods</h3><div>50 patients with ankle injury were scanned by DECT and MRI. The articular surface was analyzed. CT and MRI images were independently evaluated by two diagnostic physicians. Using MRl as the reference standard, the diagnostic ability of energy spectrum CT and MRI was compared. The consistency of MR And CT conclusions was evaluated. Energy spectrum CT adopts virtual decalcification technology. 80keVCT value and mixed keV value were used in MRI.</div></div><div><h3>Results</h3><div>The 80keVCT value, mixed keV value and Rho value of EDCT before the tear of talofibular ligament were significantly lower than that of intact ligament. The optimal critical value was 80keV and CT value was 65HU. The mixed keV value was 64.5. There was no difference in diagnosis between MRI and DECT.</div></div><div><h3>Conclusion</h3><div>DECT is accurate and reliable in the diagnosis of anterior talofibular ligament tear.</div></div>","PeriodicalId":46420,"journal":{"name":"Journal of Medical Imaging and Radiation Sciences","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Imaging and Radiation Sciences","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1939865424002339","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Objective
To evaluate the diagnostic value of energy spectrum CT in structural injury of anterior talofibular ligament using MRI as reference standard.
Methods
50 patients with ankle injury were scanned by DECT and MRI. The articular surface was analyzed. CT and MRI images were independently evaluated by two diagnostic physicians. Using MRl as the reference standard, the diagnostic ability of energy spectrum CT and MRI was compared. The consistency of MR And CT conclusions was evaluated. Energy spectrum CT adopts virtual decalcification technology. 80keVCT value and mixed keV value were used in MRI.
Results
The 80keVCT value, mixed keV value and Rho value of EDCT before the tear of talofibular ligament were significantly lower than that of intact ligament. The optimal critical value was 80keV and CT value was 65HU. The mixed keV value was 64.5. There was no difference in diagnosis between MRI and DECT.
Conclusion
DECT is accurate and reliable in the diagnosis of anterior talofibular ligament tear.
期刊介绍:
Journal of Medical Imaging and Radiation Sciences is the official peer-reviewed journal of the Canadian Association of Medical Radiation Technologists. This journal is published four times a year and is circulated to approximately 11,000 medical radiation technologists, libraries and radiology departments throughout Canada, the United States and overseas. The Journal publishes articles on recent research, new technology and techniques, professional practices, technologists viewpoints as well as relevant book reviews.