Amir H Nejat, Mehmet Esad Güven, Gülce Çakmak, Burak Yilmaz, Mustafa Borga Donmez
{"title":"Effect of build orientation on the fabrication trueness of additively manufactured implant-supported complete arch interim fixed prostheses.","authors":"Amir H Nejat, Mehmet Esad Güven, Gülce Çakmak, Burak Yilmaz, Mustafa Borga Donmez","doi":"10.1111/jopr.13972","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate how build orientation affects the fabrication trueness of additively manufactured implant-supported complete arch prostheses by comparing them to subtractively manufactured high-impact polymer-based prostheses.</p><p><strong>Materials and methods: </strong>An edentulous maxillary model with four implants at canine and first molar regions bilaterally was digitized (ATOS Core 80 5MP) to design a reference implant-supported complete arch prosthesis standard tessellation language file (RF-STL). The STL file was used to manufacture prostheses additively in five different orientations according to the build platform (AM-0, 0-degree; AM-15, 15-degree; AM-30, 30-degree; AM-45, 45-degree; AM-90, 90-degree) or subtractively (SM-HIP, control) (n = 10). The prostheses were digitized with an intraoral scanner (Trios 3) to generate their STLs (TF-STL). After superimposing TF-STLs over the RF-STL with a metrology-grade analysis software program (Geomagic Control X), surface deviations at four regions (overall, occlusal, overall without occlusal, and abutments), linear deviations at each abutment site, and interimplant distance deviations (canine-to-molar, canine-to-canine, and molar-to-molar) were calculated. One-way analysis of variance and Tukey HSD tests were used for the statistical analyses (α = 0.05).</p><p><strong>Results: </strong>AM-90 mostly had the highest surface deviations, while AM-0 had the lowest overall, and lowest overall without occlusal region deviations (p ≤ 0.022). SM-HIP had the lowest occlusal region deviations (p < 0.001). AM-90 had the highest linear deviations (p < 0.001). AM-15 had higher canine-to-molar deviations than SM-HIP (p = 0.042). SM-HIP had the highest canine-to-canine deviations, while AM-90 had higher deviations than AM-0 and AM-30 (p ≤ 0.026). AM-45 and AM-90 had the highest and AM-0 had the lowest molar-to-molar deviations (p ≤ 0.013).</p><p><strong>Conclusions: </strong>AM-0 mostly had higher trueness and AM-90 mostly had lower trueness within tested outcomes. Additively manufactured prostheses mostly had lower canine-to-molar distances and higher molar-to-molar distances, whereas SM-HIP prostheses consistently had higher distances than the design file.</p>","PeriodicalId":49152,"journal":{"name":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2024-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jopr.13972","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To evaluate how build orientation affects the fabrication trueness of additively manufactured implant-supported complete arch prostheses by comparing them to subtractively manufactured high-impact polymer-based prostheses.
Materials and methods: An edentulous maxillary model with four implants at canine and first molar regions bilaterally was digitized (ATOS Core 80 5MP) to design a reference implant-supported complete arch prosthesis standard tessellation language file (RF-STL). The STL file was used to manufacture prostheses additively in five different orientations according to the build platform (AM-0, 0-degree; AM-15, 15-degree; AM-30, 30-degree; AM-45, 45-degree; AM-90, 90-degree) or subtractively (SM-HIP, control) (n = 10). The prostheses were digitized with an intraoral scanner (Trios 3) to generate their STLs (TF-STL). After superimposing TF-STLs over the RF-STL with a metrology-grade analysis software program (Geomagic Control X), surface deviations at four regions (overall, occlusal, overall without occlusal, and abutments), linear deviations at each abutment site, and interimplant distance deviations (canine-to-molar, canine-to-canine, and molar-to-molar) were calculated. One-way analysis of variance and Tukey HSD tests were used for the statistical analyses (α = 0.05).
Results: AM-90 mostly had the highest surface deviations, while AM-0 had the lowest overall, and lowest overall without occlusal region deviations (p ≤ 0.022). SM-HIP had the lowest occlusal region deviations (p < 0.001). AM-90 had the highest linear deviations (p < 0.001). AM-15 had higher canine-to-molar deviations than SM-HIP (p = 0.042). SM-HIP had the highest canine-to-canine deviations, while AM-90 had higher deviations than AM-0 and AM-30 (p ≤ 0.026). AM-45 and AM-90 had the highest and AM-0 had the lowest molar-to-molar deviations (p ≤ 0.013).
Conclusions: AM-0 mostly had higher trueness and AM-90 mostly had lower trueness within tested outcomes. Additively manufactured prostheses mostly had lower canine-to-molar distances and higher molar-to-molar distances, whereas SM-HIP prostheses consistently had higher distances than the design file.
期刊介绍:
The Journal of Prosthodontics promotes the advanced study and practice of prosthodontics, implant, esthetic, and reconstructive dentistry. It is the official journal of the American College of Prosthodontists, the American Dental Association-recognized voice of the Specialty of Prosthodontics. The journal publishes evidence-based original scientific articles presenting information that is relevant and useful to prosthodontists. Additionally, it publishes reports of innovative techniques, new instructional methodologies, and instructive clinical reports with an interdisciplinary flair. The journal is particularly focused on promoting the study and use of cutting-edge technology and positioning prosthodontists as the early-adopters of new technology in the dental community.