{"title":"Comprehensive validation of a compact laser speckle contrast imaging system for vascular function assessment: from the laboratory to the clinic.","authors":"Meng-Che Hsieh, Chia-Yu Chang, Ching-Han Hsu, Congo Tak Shing Ching, Lun-De Liao","doi":"10.1007/s11517-024-03211-y","DOIUrl":null,"url":null,"abstract":"<p><p>Proper organ functioning relies on adequate blood circulation; thus, monitoring blood flow is crucial for early disease diagnosis. Laser speckle contrast imaging (LSCI) is a noninvasive technique that is widely used for measuring superficial blood flow. In this study, we developed a portable LSCI system using an 805-nm near-infrared laser and a monochrome CMOS camera with a 10 × macro zoom lens. The system achieved a high-resolution imaging (1280 × 1024 pixels) with a working distance of 10 to 35 cm. The relative flow velocities were visualized via a spatial speckle contrast analysis algorithm with a 5 × 5 sliding window. In vitro experiments demonstrated the system's ability to image flow velocities in a fluid model, and a linear relationship was observed between the actual flow rate and the relative flow rate obtained by the system. The correlation coefficient (R<sup>2</sup>) exceeded 0.83 for volumetric flow rates of 0 to 0.2 ml/min when channel widths were greater than 1.2 mm, and R<sup>2</sup> > 0.94 was obtained for channel widths exceeding 1.6 mm. Comparisons with laser Doppler flowmetry (LDF) revealed a strong positive correlation between the LSCI and LDF results. In vivo experiments captured postocclusive reactive hyperemic responses in rat hind limbs and human palms and feet. The main research contribution is the development of this compact and portable LSCI device, as well as the validation of its reliability and convenience in various scenarios and environments. Future applications of this technology include evaluating blood flow changes during skin injuries, such as abrasions, burns, and diabetic foot ulcers, to aid medical institutions in treatment optimization and to reduce treatment duration.</p>","PeriodicalId":49840,"journal":{"name":"Medical & Biological Engineering & Computing","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2024-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical & Biological Engineering & Computing","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s11517-024-03211-y","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0
Abstract
Proper organ functioning relies on adequate blood circulation; thus, monitoring blood flow is crucial for early disease diagnosis. Laser speckle contrast imaging (LSCI) is a noninvasive technique that is widely used for measuring superficial blood flow. In this study, we developed a portable LSCI system using an 805-nm near-infrared laser and a monochrome CMOS camera with a 10 × macro zoom lens. The system achieved a high-resolution imaging (1280 × 1024 pixels) with a working distance of 10 to 35 cm. The relative flow velocities were visualized via a spatial speckle contrast analysis algorithm with a 5 × 5 sliding window. In vitro experiments demonstrated the system's ability to image flow velocities in a fluid model, and a linear relationship was observed between the actual flow rate and the relative flow rate obtained by the system. The correlation coefficient (R2) exceeded 0.83 for volumetric flow rates of 0 to 0.2 ml/min when channel widths were greater than 1.2 mm, and R2 > 0.94 was obtained for channel widths exceeding 1.6 mm. Comparisons with laser Doppler flowmetry (LDF) revealed a strong positive correlation between the LSCI and LDF results. In vivo experiments captured postocclusive reactive hyperemic responses in rat hind limbs and human palms and feet. The main research contribution is the development of this compact and portable LSCI device, as well as the validation of its reliability and convenience in various scenarios and environments. Future applications of this technology include evaluating blood flow changes during skin injuries, such as abrasions, burns, and diabetic foot ulcers, to aid medical institutions in treatment optimization and to reduce treatment duration.
期刊介绍:
Founded in 1963, Medical & Biological Engineering & Computing (MBEC) continues to serve the biomedical engineering community, covering the entire spectrum of biomedical and clinical engineering. The journal presents exciting and vital experimental and theoretical developments in biomedical science and technology, and reports on advances in computer-based methodologies in these multidisciplinary subjects. The journal also incorporates new and evolving technologies including cellular engineering and molecular imaging.
MBEC publishes original research articles as well as reviews and technical notes. Its Rapid Communications category focuses on material of immediate value to the readership, while the Controversies section provides a forum to exchange views on selected issues, stimulating a vigorous and informed debate in this exciting and high profile field.
MBEC is an official journal of the International Federation of Medical and Biological Engineering (IFMBE).