Netilmicin disk susceptibility tests: effect of cations on the MIC correlates.

A L Barry, G H Miller, R S Hare, C Thornsberry, R N Jones
{"title":"Netilmicin disk susceptibility tests: effect of cations on the MIC correlates.","authors":"A L Barry,&nbsp;G H Miller,&nbsp;R S Hare,&nbsp;C Thornsberry,&nbsp;R N Jones","doi":"10.1007/BF02013098","DOIUrl":null,"url":null,"abstract":"<p><p>When testing Pseudomonas aeruginosa against netilmicin, MICs were markedly affected by the concentration of cations added to the test medium. A susceptible disk test result (zone greater than or equal to 15 mm) corresponded to MIC less than or equal to 4.0 micrograms/ml in unsupplemented broth, less than or equal to 12 micrograms/ml in broth with half the usual amount of cations and less than or equal to 32 micrograms/ml in broth with the recommended concentration of cations. Tests with 30 micrograms netilmicin disks best predicted susceptibility as determined by MICs in broth without added cations. When the MICs were determined in cation supplemented broth, the number of interpretive discrepancies increased to an unacceptably high level.</p>","PeriodicalId":11958,"journal":{"name":"European Journal of Clinical Microbiology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1987-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF02013098","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Clinical Microbiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/BF02013098","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

When testing Pseudomonas aeruginosa against netilmicin, MICs were markedly affected by the concentration of cations added to the test medium. A susceptible disk test result (zone greater than or equal to 15 mm) corresponded to MIC less than or equal to 4.0 micrograms/ml in unsupplemented broth, less than or equal to 12 micrograms/ml in broth with half the usual amount of cations and less than or equal to 32 micrograms/ml in broth with the recommended concentration of cations. Tests with 30 micrograms netilmicin disks best predicted susceptibility as determined by MICs in broth without added cations. When the MICs were determined in cation supplemented broth, the number of interpretive discrepancies increased to an unacceptably high level.

奈替米星药敏试验:阳离子对MIC相关物的影响。
当测试铜绿假单胞菌对奈替米星的作用时,mic受到添加到测试培养基中的阳离子浓度的显著影响。敏感盘试验结果(区域大于或等于15mm)对应的MIC值在未添加的肉汤中小于或等于4.0微克/毫升,在含有通常阳离子量的一半的肉汤中小于或等于12微克/毫升,在含有推荐阳离子浓度的肉汤中小于或等于32微克/毫升。在不添加阳离子的肉汤中,用mic测定30微克奈替米星圆盘的试验最能预测药敏。当在添加阳离子的肉汤中测定mic时,解释差异的数量增加到不可接受的高水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信