{"title":"Nanofluid effect on dual-flow parabolic trough collector performance accompanies with passive technique using experimental data","authors":"Ali Akbar Abbasian Arani, Ali Memarzadeh","doi":"10.1108/hff-03-2024-0247","DOIUrl":null,"url":null,"abstract":"<h3>Purpose</h3>\n<p>Using passive techniques like twisted tapes and corrugated surface is an efficient method of heat transfer improvement, since the referred manners break the boundary layer and improve the heat exchange. This paper aims to present an improved dual-flow parabolic trough collector (PTC). For this purpose, the effect of an absorber roof, a type of turbulator and a grooved absorber tube in the presence of nanofluid is investigated separately and simultaneously.</p><!--/ Abstract__block -->\n<h3>Design/methodology/approach</h3>\n<p>The FLUENT was used for solution of governing equation using control volume scheme. The control volume scheme has been used for solving the governing equations using the finite volume method. The standard k–e turbulence model has been chosen.</p><!--/ Abstract__block -->\n<h3>Findings</h3>\n<p>Fluid flow and heat transfer features, as friction factor, performance evaluation criteria (PEC) and Nusselt number have been calculated and analyzed. It is showed that absorber roof intensifies the heat transfer ratio in PTCs. Also, the combination of inserting the turbulator, outer corrugated and inner grooved absorber tube surface can enhance the PEC of PTCs considerably.</p><!--/ Abstract__block -->\n<h3>Originality/value</h3>\n<p>Results of the current study show that the PTC with two heat transfer fluids, outer and inner surface corrugated absorber tube, inserting the twisted tape and absorber roof have the maximum Nusselt number ratio equal to 5, and PEC higher than 2.5 between all proposed arrangements for investigated Reynolds numbers (from 10,000 to 20,000) and nanoparticles [Boehmite alumina (“λ-AlOOH)”] volume fractions (from 0.005 to 0.03). Maximum Nusselt number and PEC correspond to nanoparticle volume fraction and Reynolds number equal to 0.03 and 20,000, respectively. Besides, it was found that the performance evaluation criteria index values continuously grow by an intensification of nanoparticle volume concentrations.</p><!--/ Abstract__block -->","PeriodicalId":14263,"journal":{"name":"International Journal of Numerical Methods for Heat & Fluid Flow","volume":"3 1","pages":""},"PeriodicalIF":4.0000,"publicationDate":"2024-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Numerical Methods for Heat & Fluid Flow","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1108/hff-03-2024-0247","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MATHEMATICS, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose
Using passive techniques like twisted tapes and corrugated surface is an efficient method of heat transfer improvement, since the referred manners break the boundary layer and improve the heat exchange. This paper aims to present an improved dual-flow parabolic trough collector (PTC). For this purpose, the effect of an absorber roof, a type of turbulator and a grooved absorber tube in the presence of nanofluid is investigated separately and simultaneously.
Design/methodology/approach
The FLUENT was used for solution of governing equation using control volume scheme. The control volume scheme has been used for solving the governing equations using the finite volume method. The standard k–e turbulence model has been chosen.
Findings
Fluid flow and heat transfer features, as friction factor, performance evaluation criteria (PEC) and Nusselt number have been calculated and analyzed. It is showed that absorber roof intensifies the heat transfer ratio in PTCs. Also, the combination of inserting the turbulator, outer corrugated and inner grooved absorber tube surface can enhance the PEC of PTCs considerably.
Originality/value
Results of the current study show that the PTC with two heat transfer fluids, outer and inner surface corrugated absorber tube, inserting the twisted tape and absorber roof have the maximum Nusselt number ratio equal to 5, and PEC higher than 2.5 between all proposed arrangements for investigated Reynolds numbers (from 10,000 to 20,000) and nanoparticles [Boehmite alumina (“λ-AlOOH)”] volume fractions (from 0.005 to 0.03). Maximum Nusselt number and PEC correspond to nanoparticle volume fraction and Reynolds number equal to 0.03 and 20,000, respectively. Besides, it was found that the performance evaluation criteria index values continuously grow by an intensification of nanoparticle volume concentrations.
期刊介绍:
The main objective of this international journal is to provide applied mathematicians, engineers and scientists engaged in computer-aided design and research in computational heat transfer and fluid dynamics, whether in academic institutions of industry, with timely and accessible information on the development, refinement and application of computer-based numerical techniques for solving problems in heat and fluid flow. - See more at: http://emeraldgrouppublishing.com/products/journals/journals.htm?id=hff#sthash.Kf80GRt8.dpuf