CATransformer: A Cycle-Aware Transformer for High-Fidelity ECG Generation From PPG.

IF 6.7 2区 医学 Q1 COMPUTER SCIENCE, INFORMATION SYSTEMS
Xiaoyan Yuan, Wei Wang, Xiaohe Li, Yuanting Zhang, Xiping Hu, M Jamal Deen
{"title":"CATransformer: A Cycle-Aware Transformer for High-Fidelity ECG Generation From PPG.","authors":"Xiaoyan Yuan, Wei Wang, Xiaohe Li, Yuanting Zhang, Xiping Hu, M Jamal Deen","doi":"10.1109/JBHI.2024.3482853","DOIUrl":null,"url":null,"abstract":"<p><p>Electrocardiography (ECG) is the gold standard for monitoring heart function and is crucial for preventing the worsening of cardiovascular diseases (CVDs). However, the inconvenience of ECG acquisition poses challenges for long-term continuous monitoring. Consequently, researchers have explored non-invasive and easily accessible photoplethysmography (PPG) as an alternative, converting it into ECG. Previous studies have focused on peaks or simple mapping to generate ECG, ignoring the inherent periodicity of cardiovascular signals. This results in an inability to accurately extract physiological information during the cycle, thus compromising the generated ECG signals' clinical utility. To this end, we introduce a novel PPG-to-ECG translation model called CATransformer, capable of adaptive modeling based on the cardiac cycle. Specifically, CATransformer automatically extracts the cycle using a cycle-aware module and creates multiple semantic views of the cardiac cycle. It leverages a transformer to capture detailed features within each cycle and the dynamics across cycles. Our method outperforms existing approaches, exhibiting the lowest RMSE across five paired PPG-ECG databases. Additionally, extensive experiments are conducted on four cardiovascular-related tasks to assess the clinical utility of the generated ECG, achieving consistent state-of-the-art performance. Experimental results confirm that CATransformer generates highly faithful ECG signals while preserving their physiological characteristics.</p>","PeriodicalId":13073,"journal":{"name":"IEEE Journal of Biomedical and Health Informatics","volume":null,"pages":null},"PeriodicalIF":6.7000,"publicationDate":"2024-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Journal of Biomedical and Health Informatics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1109/JBHI.2024.3482853","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"COMPUTER SCIENCE, INFORMATION SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Electrocardiography (ECG) is the gold standard for monitoring heart function and is crucial for preventing the worsening of cardiovascular diseases (CVDs). However, the inconvenience of ECG acquisition poses challenges for long-term continuous monitoring. Consequently, researchers have explored non-invasive and easily accessible photoplethysmography (PPG) as an alternative, converting it into ECG. Previous studies have focused on peaks or simple mapping to generate ECG, ignoring the inherent periodicity of cardiovascular signals. This results in an inability to accurately extract physiological information during the cycle, thus compromising the generated ECG signals' clinical utility. To this end, we introduce a novel PPG-to-ECG translation model called CATransformer, capable of adaptive modeling based on the cardiac cycle. Specifically, CATransformer automatically extracts the cycle using a cycle-aware module and creates multiple semantic views of the cardiac cycle. It leverages a transformer to capture detailed features within each cycle and the dynamics across cycles. Our method outperforms existing approaches, exhibiting the lowest RMSE across five paired PPG-ECG databases. Additionally, extensive experiments are conducted on four cardiovascular-related tasks to assess the clinical utility of the generated ECG, achieving consistent state-of-the-art performance. Experimental results confirm that CATransformer generates highly faithful ECG signals while preserving their physiological characteristics.

CATransformer:从 PPG 生成高保真心电图的周期感知变压器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Journal of Biomedical and Health Informatics
IEEE Journal of Biomedical and Health Informatics COMPUTER SCIENCE, INFORMATION SYSTEMS-COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS
CiteScore
13.60
自引率
6.50%
发文量
1151
期刊介绍: IEEE Journal of Biomedical and Health Informatics publishes original papers presenting recent advances where information and communication technologies intersect with health, healthcare, life sciences, and biomedicine. Topics include acquisition, transmission, storage, retrieval, management, and analysis of biomedical and health information. The journal covers applications of information technologies in healthcare, patient monitoring, preventive care, early disease diagnosis, therapy discovery, and personalized treatment protocols. It explores electronic medical and health records, clinical information systems, decision support systems, medical and biological imaging informatics, wearable systems, body area/sensor networks, and more. Integration-related topics like interoperability, evidence-based medicine, and secure patient data are also addressed.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信