{"title":"STARTS: A Self-Adapted Spatio-Temporal Framework for Automatic E/MEG Source Imaging","authors":"Zhao Feng;Cuntai Guan;Ruifeng Zheng;Yu Sun","doi":"10.1109/TMI.2024.3483292","DOIUrl":null,"url":null,"abstract":"To obtain accurate brain source activities, the highly ill-posed source imaging of electro- and magneto-encephalography (E/MEG) requires proficiency in incorporation of biophysiological constraints and signal-processing techniques. Here, we propose a spatio-temporal-constrainted E/MEG source imaging framework-STARTS that can reconstruct the source in a fully automatic way. Specifically, a block-diagonal covariance was adopted to reconstruct the source extents while maintain spatial homogeneity. Temporal basis functions (TBFs) of both sources and noise were estimated and updated in a data-driven fashion to alleviate the influence of noises and further improve source localization accuracy. The performance of the proposed STARTS was quantitatively assessed through a series of simulation experiments, wherein superior results were obtained in comparison with the benchmark ESI algorithms (including LORETA, EBI-Convex, BESTIES & SI-STBF). Additional validations on epileptic and resting-state EEG data further indicate that the STARTS can produce neurophysiologically plausible results. Moreover, a computationally efficient version of STARTS: smooth STARTS was also introduced with an elementary spatial constraint, which exhibited comparable performance and reduced execution cost. In sum, the proposed STARTS, with its advanced spatio-temporal constraints and self-adapted update operation, provides an effective and efficient approach for E/MEG source imaging.","PeriodicalId":94033,"journal":{"name":"IEEE transactions on medical imaging","volume":"44 3","pages":"1230-1242"},"PeriodicalIF":0.0000,"publicationDate":"2024-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on medical imaging","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10721601/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
To obtain accurate brain source activities, the highly ill-posed source imaging of electro- and magneto-encephalography (E/MEG) requires proficiency in incorporation of biophysiological constraints and signal-processing techniques. Here, we propose a spatio-temporal-constrainted E/MEG source imaging framework-STARTS that can reconstruct the source in a fully automatic way. Specifically, a block-diagonal covariance was adopted to reconstruct the source extents while maintain spatial homogeneity. Temporal basis functions (TBFs) of both sources and noise were estimated and updated in a data-driven fashion to alleviate the influence of noises and further improve source localization accuracy. The performance of the proposed STARTS was quantitatively assessed through a series of simulation experiments, wherein superior results were obtained in comparison with the benchmark ESI algorithms (including LORETA, EBI-Convex, BESTIES & SI-STBF). Additional validations on epileptic and resting-state EEG data further indicate that the STARTS can produce neurophysiologically plausible results. Moreover, a computationally efficient version of STARTS: smooth STARTS was also introduced with an elementary spatial constraint, which exhibited comparable performance and reduced execution cost. In sum, the proposed STARTS, with its advanced spatio-temporal constraints and self-adapted update operation, provides an effective and efficient approach for E/MEG source imaging.