Effect of Quadriceps Tendon Autograft Preparation and Fixation on Graft Laxity During Suspensory Anterior Cruciate Ligament Reconstruction: A Biomechanical Analysis.
Asheesh Bedi, Benjamin L Smith, Justin J Mitchell, Rachel M Frank, Oliver L Hauck, Coen A Wijdicks
{"title":"Effect of Quadriceps Tendon Autograft Preparation and Fixation on Graft Laxity During Suspensory Anterior Cruciate Ligament Reconstruction: A Biomechanical Analysis.","authors":"Asheesh Bedi, Benjamin L Smith, Justin J Mitchell, Rachel M Frank, Oliver L Hauck, Coen A Wijdicks","doi":"10.1177/23259671241288578","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Favorable collagen fibril density and thickness combined with advances in graft preparation and fixation have significantly increased interest in the quadriceps tendon (QT) autograft for anterior cruciate ligament (ACL) reconstruction. While various suspensory techniques have been described, the biomechanical profile of these constructs is largely undefined.</p><p><strong>Purpose: </strong>To compare the biomechanics of suspensory techniques for soft tissue QT autograft fixation in an in vitro model of ACL reconstruction.</p><p><strong>Study design: </strong>Controlled laboratory study.</p><p><strong>Methods: </strong>Full-thickness QT grafts were harvested using a 9-mm graft blade. Adjustable-loop devices (ALDs) were secured to the graft (n = 6 per group) with a combination implant containing the ALD and suture tape-reinforced whipstitching (tape-reinforced [TR] group), tethered superficially to the graft with a whipstitch (onlay [OL] group), luggage-tagged through and around the graft (luggage tag [LT] group), or staggered behind superficial suturing (staggered [SG] group). Grafts were tested on an electromechanical testing machine following a validated in vitro reconstruction model of intraoperative workflow and postoperative ACL kinematics, cyclic loading, and load to failure.</p><p><strong>Results: </strong>The TR group had significantly less postcyclic tension loss (mean, 24%) compared with the OL (56%; <i>P</i> = .002), LT (69%; <i>P</i> < .001), and SG (90%; <i>P</i> < .001) constructs. Cyclic elongation was below the 3.0-mm threshold defined as clinical failure for TR (1.6 mm), but not for OL (3.3 mm), LT (7.9 mm), and SG (11.3 mm). All constructs were within native ACL stiffness limits (220 ± 72 N/mm) without significant differences. Ultimate loads significantly exceeded a normal ACL loading limit of 454 N for TR (739 N; <i>P</i> = .023), OL (547 N; <i>P</i> = .020), and LT (769 N; <i>P</i> = .001), but not for SG (346 N; <i>P</i> = .236).</p><p><strong>Conclusion: </strong>The TR ALD construct demonstrated the most favorable time-zero biomechanical properties of modern soft tissue QT suspensory constructs, with 32% less tension loss and 52% less cyclic elongation versus the closest construct. Failure loading of all constructs was acceptable with respect to the native ACL except for the SG group, which had suboptimal ultimate load.</p><p><strong>Clinical relevance: </strong>TR ALD implants may protect soft tissue QT autografts before graft-bone healing in ACL reconstruction by minimizing time-zero laxity and fixation failure.</p>","PeriodicalId":19646,"journal":{"name":"Orthopaedic Journal of Sports Medicine","volume":"12 10","pages":"23259671241288578"},"PeriodicalIF":2.4000,"publicationDate":"2024-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11465362/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthopaedic Journal of Sports Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/23259671241288578","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Favorable collagen fibril density and thickness combined with advances in graft preparation and fixation have significantly increased interest in the quadriceps tendon (QT) autograft for anterior cruciate ligament (ACL) reconstruction. While various suspensory techniques have been described, the biomechanical profile of these constructs is largely undefined.
Purpose: To compare the biomechanics of suspensory techniques for soft tissue QT autograft fixation in an in vitro model of ACL reconstruction.
Study design: Controlled laboratory study.
Methods: Full-thickness QT grafts were harvested using a 9-mm graft blade. Adjustable-loop devices (ALDs) were secured to the graft (n = 6 per group) with a combination implant containing the ALD and suture tape-reinforced whipstitching (tape-reinforced [TR] group), tethered superficially to the graft with a whipstitch (onlay [OL] group), luggage-tagged through and around the graft (luggage tag [LT] group), or staggered behind superficial suturing (staggered [SG] group). Grafts were tested on an electromechanical testing machine following a validated in vitro reconstruction model of intraoperative workflow and postoperative ACL kinematics, cyclic loading, and load to failure.
Results: The TR group had significantly less postcyclic tension loss (mean, 24%) compared with the OL (56%; P = .002), LT (69%; P < .001), and SG (90%; P < .001) constructs. Cyclic elongation was below the 3.0-mm threshold defined as clinical failure for TR (1.6 mm), but not for OL (3.3 mm), LT (7.9 mm), and SG (11.3 mm). All constructs were within native ACL stiffness limits (220 ± 72 N/mm) without significant differences. Ultimate loads significantly exceeded a normal ACL loading limit of 454 N for TR (739 N; P = .023), OL (547 N; P = .020), and LT (769 N; P = .001), but not for SG (346 N; P = .236).
Conclusion: The TR ALD construct demonstrated the most favorable time-zero biomechanical properties of modern soft tissue QT suspensory constructs, with 32% less tension loss and 52% less cyclic elongation versus the closest construct. Failure loading of all constructs was acceptable with respect to the native ACL except for the SG group, which had suboptimal ultimate load.
Clinical relevance: TR ALD implants may protect soft tissue QT autografts before graft-bone healing in ACL reconstruction by minimizing time-zero laxity and fixation failure.
期刊介绍:
The Orthopaedic Journal of Sports Medicine (OJSM), developed by the American Orthopaedic Society for Sports Medicine (AOSSM), is a global, peer-reviewed, open access journal that combines the interests of researchers and clinical practitioners across orthopaedic sports medicine, arthroscopy, and knee arthroplasty.
Topics include original research in the areas of:
-Orthopaedic Sports Medicine, including surgical and nonsurgical treatment of orthopaedic sports injuries
-Arthroscopic Surgery (Shoulder/Elbow/Wrist/Hip/Knee/Ankle/Foot)
-Relevant translational research
-Sports traumatology/epidemiology
-Knee and shoulder arthroplasty
The OJSM also publishes relevant systematic reviews and meta-analyses.
This journal is a member of the Committee on Publication Ethics (COPE).